Cargando…

Porosity of Bleb Capsule declines rapidly with Fluid Challenge

INTRODUCTION: The porosity of the fibrous capsule around a glaucoma drainage device (GDD) may be the most important functional attribute. The factors that determine capsular porosity are not well understood. Failed GDD surgeries are usually associated with thick impervious capsules and components of...

Descripción completa

Detalles Bibliográficos
Autores principales: Pandav, Surinder S, Ross, Craig M, Thattaruthody, Faisal, Nada, Ritambhra, Singh, Nirbhai, Gautam, Natasha, Beirne, Stephen, Wallace, Gordon G, Sherwood, Mark B, Crowston, Jonathan G, Coote, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5104968/
https://www.ncbi.nlm.nih.gov/pubmed/27857488
http://dx.doi.org/10.5005/jp-journals-10008-1208
_version_ 1782466819344302080
author Pandav, Surinder S
Ross, Craig M
Thattaruthody, Faisal
Nada, Ritambhra
Singh, Nirbhai
Gautam, Natasha
Beirne, Stephen
Wallace, Gordon G
Sherwood, Mark B
Crowston, Jonathan G
Coote, Michael
author_facet Pandav, Surinder S
Ross, Craig M
Thattaruthody, Faisal
Nada, Ritambhra
Singh, Nirbhai
Gautam, Natasha
Beirne, Stephen
Wallace, Gordon G
Sherwood, Mark B
Crowston, Jonathan G
Coote, Michael
author_sort Pandav, Surinder S
collection PubMed
description INTRODUCTION: The porosity of the fibrous capsule around a glaucoma drainage device (GDD) may be the most important functional attribute. The factors that determine capsular porosity are not well understood. Failed GDD surgeries are usually associated with thick impervious capsules and components of aqueous have been implicated in this process. PURPOSE: In this study, we interrogated the effect of passage of nonaqueous fluid on capsular porosity in mature (but aqueous naïve) blebs in a previously reported GDD model (the “Center for Eye Research Australia Implant”). MATERIALS AND METHODS: The study was performed at two centers using 17 New Zealand White (NZW) rabbits. An experimental GDD was implanted into the subconjunctival space but without connection to the anterior chamber. After 28 days, balanced salt solution (BSS) was passed through the implant for 30 to 40 minutes at 12 mm Hg. Capsular porosity was measured as flow (μL/min) at a constant pressure. Porosity of the capsule was retested at 3 and 6 days. RESULTS: There was a marked reduction in capsular porosity within 3 days of exposure to BSS (fluid challenge). Even though the baseline porosity was significantly different in the two groups (3.00 ± 0.5 μL/min and 29.67 ± 12.12 μL/min, p < 0.001), the effect of passage of BSS was similar. Capsular porosity fell by approximately 80% in both groups from baseline after single BSS challenge. Capsular thickness was significantly less in Advanced Eye Center (AEC) rabbits at baseline. There was no change in the capsular thickness before and after single fluid challenge. CONCLUSION: Passage of BSS at physiological pressures for under 40 minutes caused marked reduction in the porosity of the fibrous capsule within 3 days. This was not associated with any significant thickening of the fibrous capsule within this time frame. HOW TO CITE THIS ARTICLE: Pandav SS, Ross CM, Thattaruthody F, Nada R, Singh N, Gautam N, Beirne S, Wallace GG, Sherwood MB, Crowston JG, Coote M. Porosity of Bleb Capsule declines rapidly with Fluid Challenge. J Curr Glaucoma Pract 2016;10(3):91-96.
format Online
Article
Text
id pubmed-5104968
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-51049682016-11-17 Porosity of Bleb Capsule declines rapidly with Fluid Challenge Pandav, Surinder S Ross, Craig M Thattaruthody, Faisal Nada, Ritambhra Singh, Nirbhai Gautam, Natasha Beirne, Stephen Wallace, Gordon G Sherwood, Mark B Crowston, Jonathan G Coote, Michael J Curr Glaucoma Pract Original Article INTRODUCTION: The porosity of the fibrous capsule around a glaucoma drainage device (GDD) may be the most important functional attribute. The factors that determine capsular porosity are not well understood. Failed GDD surgeries are usually associated with thick impervious capsules and components of aqueous have been implicated in this process. PURPOSE: In this study, we interrogated the effect of passage of nonaqueous fluid on capsular porosity in mature (but aqueous naïve) blebs in a previously reported GDD model (the “Center for Eye Research Australia Implant”). MATERIALS AND METHODS: The study was performed at two centers using 17 New Zealand White (NZW) rabbits. An experimental GDD was implanted into the subconjunctival space but without connection to the anterior chamber. After 28 days, balanced salt solution (BSS) was passed through the implant for 30 to 40 minutes at 12 mm Hg. Capsular porosity was measured as flow (μL/min) at a constant pressure. Porosity of the capsule was retested at 3 and 6 days. RESULTS: There was a marked reduction in capsular porosity within 3 days of exposure to BSS (fluid challenge). Even though the baseline porosity was significantly different in the two groups (3.00 ± 0.5 μL/min and 29.67 ± 12.12 μL/min, p < 0.001), the effect of passage of BSS was similar. Capsular porosity fell by approximately 80% in both groups from baseline after single BSS challenge. Capsular thickness was significantly less in Advanced Eye Center (AEC) rabbits at baseline. There was no change in the capsular thickness before and after single fluid challenge. CONCLUSION: Passage of BSS at physiological pressures for under 40 minutes caused marked reduction in the porosity of the fibrous capsule within 3 days. This was not associated with any significant thickening of the fibrous capsule within this time frame. HOW TO CITE THIS ARTICLE: Pandav SS, Ross CM, Thattaruthody F, Nada R, Singh N, Gautam N, Beirne S, Wallace GG, Sherwood MB, Crowston JG, Coote M. Porosity of Bleb Capsule declines rapidly with Fluid Challenge. J Curr Glaucoma Pract 2016;10(3):91-96. Jaypee Brothers Medical Publishers 2016 2016-10-29 /pmc/articles/PMC5104968/ /pubmed/27857488 http://dx.doi.org/10.5005/jp-journals-10008-1208 Text en Copyright © 2016; Jaypee Brothers Medical Publishers (P) Ltd. This work is licensed under a Creative Commons Attribution 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by/3.0/
spellingShingle Original Article
Pandav, Surinder S
Ross, Craig M
Thattaruthody, Faisal
Nada, Ritambhra
Singh, Nirbhai
Gautam, Natasha
Beirne, Stephen
Wallace, Gordon G
Sherwood, Mark B
Crowston, Jonathan G
Coote, Michael
Porosity of Bleb Capsule declines rapidly with Fluid Challenge
title Porosity of Bleb Capsule declines rapidly with Fluid Challenge
title_full Porosity of Bleb Capsule declines rapidly with Fluid Challenge
title_fullStr Porosity of Bleb Capsule declines rapidly with Fluid Challenge
title_full_unstemmed Porosity of Bleb Capsule declines rapidly with Fluid Challenge
title_short Porosity of Bleb Capsule declines rapidly with Fluid Challenge
title_sort porosity of bleb capsule declines rapidly with fluid challenge
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5104968/
https://www.ncbi.nlm.nih.gov/pubmed/27857488
http://dx.doi.org/10.5005/jp-journals-10008-1208
work_keys_str_mv AT pandavsurinders porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT rosscraigm porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT thattaruthodyfaisal porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT nadaritambhra porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT singhnirbhai porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT gautamnatasha porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT beirnestephen porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT wallacegordong porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT sherwoodmarkb porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT crowstonjonathang porosityofblebcapsuledeclinesrapidlywithfluidchallenge
AT cootemichael porosityofblebcapsuledeclinesrapidlywithfluidchallenge