An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050

AIMS: Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. SETTINGS AND DESIGN: A prospective study was carried out in a multispecialty tertiary care teaching hospital. SUBJECTS AND METHODS: A total of 835 paired specimens (797 blood and 38 nonb...

Descripción completa

Detalles Bibliográficos
Autores principales: Surase, PV, Nataraj, G, Pattamadai, K, Mehta, PR, Pazare, AR, Agarwal, MC, Nanavati, RN
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5105207/
https://www.ncbi.nlm.nih.gov/pubmed/27763479
http://dx.doi.org/10.4103/0022-3859.184958
_version_ 1782466857509322752
author Surase, PV
Nataraj, G
Pattamadai, K
Mehta, PR
Pazare, AR
Agarwal, MC
Nanavati, RN
author_facet Surase, PV
Nataraj, G
Pattamadai, K
Mehta, PR
Pazare, AR
Agarwal, MC
Nanavati, RN
author_sort Surase, PV
collection PubMed
description AIMS: Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. SETTINGS AND DESIGN: A prospective study was carried out in a multispecialty tertiary care teaching hospital. SUBJECTS AND METHODS: A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. RESULTS: Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). CONCLUSIONS: Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy.
format Online
Article
Text
id pubmed-5105207
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-51052072016-11-18 An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050 Surase, PV Nataraj, G Pattamadai, K Mehta, PR Pazare, AR Agarwal, MC Nanavati, RN J Postgrad Med Original Article AIMS: Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. SETTINGS AND DESIGN: A prospective study was carried out in a multispecialty tertiary care teaching hospital. SUBJECTS AND METHODS: A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. RESULTS: Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). CONCLUSIONS: Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5105207/ /pubmed/27763479 http://dx.doi.org/10.4103/0022-3859.184958 Text en Copyright: © 2016 Journal of Postgraduate Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Surase, PV
Nataraj, G
Pattamadai, K
Mehta, PR
Pazare, AR
Agarwal, MC
Nanavati, RN
An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050
title An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050
title_full An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050
title_fullStr An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050
title_full_unstemmed An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050
title_short An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050
title_sort appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with bactec 9050
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5105207/
https://www.ncbi.nlm.nih.gov/pubmed/27763479
http://dx.doi.org/10.4103/0022-3859.184958
work_keys_str_mv AT surasepv anappropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT natarajg anappropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT pattamadaik anappropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT mehtapr anappropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT pazarear anappropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT agarwalmc anappropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT nanavatirn anappropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT surasepv appropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT natarajg appropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT pattamadaik appropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT mehtapr appropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT pazarear appropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT agarwalmc appropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050
AT nanavatirn appropriatelyperformedconventionalbloodculturecanfacilitatechoiceoftherapyinresourceconstrainedsettingscomparisonwithbactec9050