Cargando…
A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement
Risk assessment of congestive heart failure (CHF) is essential for detection, especially helping patients make informed decisions about medications, devices, transplantation, and end-of-life care. The majority of studies have focused on disease detection between CHF patients and normal subjects usin...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5105944/ https://www.ncbi.nlm.nih.gov/pubmed/27835634 http://dx.doi.org/10.1371/journal.pone.0165304 |
_version_ | 1782466967382261760 |
---|---|
author | Chen, Wenhui Zheng, Lianrong Li, Kunyang Wang, Qian Liu, Guanzheng Jiang, Qing |
author_facet | Chen, Wenhui Zheng, Lianrong Li, Kunyang Wang, Qian Liu, Guanzheng Jiang, Qing |
author_sort | Chen, Wenhui |
collection | PubMed |
description | Risk assessment of congestive heart failure (CHF) is essential for detection, especially helping patients make informed decisions about medications, devices, transplantation, and end-of-life care. The majority of studies have focused on disease detection between CHF patients and normal subjects using short-/long-term heart rate variability (HRV) measures but not much on quantification. We downloaded 116 nominal 24-hour RR interval records from the MIT/BIH database, including 72 normal people and 44 CHF patients. These records were analyzed under a 4-level risk assessment model: no risk (normal people, N), mild risk (patients with New York Heart Association (NYHA) class I-II, P1), moderate risk (patients with NYHA III, P2), and severe risk (patients with NYHA III-IV, P3). A novel multistage classification approach is proposed for risk assessment and rating CHF using the non-equilibrium decision-tree–based support vector machine classifier. We propose dynamic indices of HRV to capture the dynamics of 5-minute short term HRV measurements for quantifying autonomic activity changes of CHF. We extracted 54 classical measures and 126 dynamic indices and selected from these using backward elimination to detect and quantify CHF patients. Experimental results show that the multistage risk assessment model can realize CHF detection and quantification analysis with total accuracy of 96.61%. The multistage model provides a powerful predictor between predicted and actual ratings, and it could serve as a clinically meaningful outcome providing an early assessment and a prognostic marker for CHF patients. |
format | Online Article Text |
id | pubmed-5105944 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-51059442016-12-08 A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement Chen, Wenhui Zheng, Lianrong Li, Kunyang Wang, Qian Liu, Guanzheng Jiang, Qing PLoS One Research Article Risk assessment of congestive heart failure (CHF) is essential for detection, especially helping patients make informed decisions about medications, devices, transplantation, and end-of-life care. The majority of studies have focused on disease detection between CHF patients and normal subjects using short-/long-term heart rate variability (HRV) measures but not much on quantification. We downloaded 116 nominal 24-hour RR interval records from the MIT/BIH database, including 72 normal people and 44 CHF patients. These records were analyzed under a 4-level risk assessment model: no risk (normal people, N), mild risk (patients with New York Heart Association (NYHA) class I-II, P1), moderate risk (patients with NYHA III, P2), and severe risk (patients with NYHA III-IV, P3). A novel multistage classification approach is proposed for risk assessment and rating CHF using the non-equilibrium decision-tree–based support vector machine classifier. We propose dynamic indices of HRV to capture the dynamics of 5-minute short term HRV measurements for quantifying autonomic activity changes of CHF. We extracted 54 classical measures and 126 dynamic indices and selected from these using backward elimination to detect and quantify CHF patients. Experimental results show that the multistage risk assessment model can realize CHF detection and quantification analysis with total accuracy of 96.61%. The multistage model provides a powerful predictor between predicted and actual ratings, and it could serve as a clinically meaningful outcome providing an early assessment and a prognostic marker for CHF patients. Public Library of Science 2016-11-11 /pmc/articles/PMC5105944/ /pubmed/27835634 http://dx.doi.org/10.1371/journal.pone.0165304 Text en © 2016 Chen et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Chen, Wenhui Zheng, Lianrong Li, Kunyang Wang, Qian Liu, Guanzheng Jiang, Qing A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement |
title | A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement |
title_full | A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement |
title_fullStr | A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement |
title_full_unstemmed | A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement |
title_short | A Novel and Effective Method for Congestive Heart Failure Detection and Quantification Using Dynamic Heart Rate Variability Measurement |
title_sort | novel and effective method for congestive heart failure detection and quantification using dynamic heart rate variability measurement |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5105944/ https://www.ncbi.nlm.nih.gov/pubmed/27835634 http://dx.doi.org/10.1371/journal.pone.0165304 |
work_keys_str_mv | AT chenwenhui anovelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT zhenglianrong anovelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT likunyang anovelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT wangqian anovelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT liuguanzheng anovelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT jiangqing anovelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT chenwenhui novelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT zhenglianrong novelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT likunyang novelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT wangqian novelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT liuguanzheng novelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement AT jiangqing novelandeffectivemethodforcongestiveheartfailuredetectionandquantificationusingdynamicheartratevariabilitymeasurement |