Cargando…

Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015

BACKGROUND: For correct interpretation of the high-density lipoprotein cholesterol (HDL-C) data from the Korea National Health and Nutrition Examination Survey (KNHANES), the values should be comparable to reference values. We aimed to suggest a way to calibrate KNHANES HDL-C data from 2008 to 2015...

Descripción completa

Detalles Bibliográficos
Autores principales: Yun, Yeo-Min, Song, Junghan, Ji, Misuk, Kim, Jeong-Ho, Kim, Yongkang, Park, Taesung, Song, Sang Hoon, Park, Seungman, Kim, Min Jin, Nho, Sun Jin, Oh, Kyung Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5107612/
https://www.ncbi.nlm.nih.gov/pubmed/27834059
http://dx.doi.org/10.3343/alm.2017.37.1.1
_version_ 1782467214487584768
author Yun, Yeo-Min
Song, Junghan
Ji, Misuk
Kim, Jeong-Ho
Kim, Yongkang
Park, Taesung
Song, Sang Hoon
Park, Seungman
Kim, Min Jin
Nho, Sun Jin
Oh, Kyung Won
author_facet Yun, Yeo-Min
Song, Junghan
Ji, Misuk
Kim, Jeong-Ho
Kim, Yongkang
Park, Taesung
Song, Sang Hoon
Park, Seungman
Kim, Min Jin
Nho, Sun Jin
Oh, Kyung Won
author_sort Yun, Yeo-Min
collection PubMed
description BACKGROUND: For correct interpretation of the high-density lipoprotein cholesterol (HDL-C) data from the Korea National Health and Nutrition Examination Survey (KNHANES), the values should be comparable to reference values. We aimed to suggest a way to calibrate KNHANES HDL-C data from 2008 to 2015 to the Centers for Disease Control and Prevention (CDC) reference method values. METHODS: We derived three calibration equations based on comparisons between the HDL-C values of the KNHANES laboratory and the CDC reference method values in 2009, 2012, and 2015 using commutable frozen serum samples. The selection of calibration equation for correcting KNHANES HDL-C in each year was determined by the accuracy-based external quality assurance results of the KNHANES laboratory. RESULTS: Significant positive biases of HDL-C values were observed in all years (2.85-9.40%). We created the following calibration equations: standard HDL-C=0.872×[original KNHANES HDL-C]+2.460 for 2008, 2009, and 2010; standard HDL-C=0.952×[original KNHANES HDL-C]+1.096 for 2012, 2013, and 2014; and standard HDL-C=1.01×[original KNHANES HDL-C]-3.172 for 2011 and 2015. We calibrated the biases of KNHANES HDL-C data using the calibration equations. CONCLUSIONS: Since the KNHANES HDL-C values (2008-2015) showed substantial positive biases compared with the CDC reference method values, we suggested using calibration equations to correct KNHANES data from these years. Since the necessity for correcting the biases depends on the characteristics of research topics, each researcher should determine whether to calibrate KNHANES HDL-C data or not for each study.
format Online
Article
Text
id pubmed-5107612
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-51076122017-01-01 Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015 Yun, Yeo-Min Song, Junghan Ji, Misuk Kim, Jeong-Ho Kim, Yongkang Park, Taesung Song, Sang Hoon Park, Seungman Kim, Min Jin Nho, Sun Jin Oh, Kyung Won Ann Lab Med Original Article BACKGROUND: For correct interpretation of the high-density lipoprotein cholesterol (HDL-C) data from the Korea National Health and Nutrition Examination Survey (KNHANES), the values should be comparable to reference values. We aimed to suggest a way to calibrate KNHANES HDL-C data from 2008 to 2015 to the Centers for Disease Control and Prevention (CDC) reference method values. METHODS: We derived three calibration equations based on comparisons between the HDL-C values of the KNHANES laboratory and the CDC reference method values in 2009, 2012, and 2015 using commutable frozen serum samples. The selection of calibration equation for correcting KNHANES HDL-C in each year was determined by the accuracy-based external quality assurance results of the KNHANES laboratory. RESULTS: Significant positive biases of HDL-C values were observed in all years (2.85-9.40%). We created the following calibration equations: standard HDL-C=0.872×[original KNHANES HDL-C]+2.460 for 2008, 2009, and 2010; standard HDL-C=0.952×[original KNHANES HDL-C]+1.096 for 2012, 2013, and 2014; and standard HDL-C=1.01×[original KNHANES HDL-C]-3.172 for 2011 and 2015. We calibrated the biases of KNHANES HDL-C data using the calibration equations. CONCLUSIONS: Since the KNHANES HDL-C values (2008-2015) showed substantial positive biases compared with the CDC reference method values, we suggested using calibration equations to correct KNHANES data from these years. Since the necessity for correcting the biases depends on the characteristics of research topics, each researcher should determine whether to calibrate KNHANES HDL-C data or not for each study. The Korean Society for Laboratory Medicine 2017-01 2016-11-01 /pmc/articles/PMC5107612/ /pubmed/27834059 http://dx.doi.org/10.3343/alm.2017.37.1.1 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yun, Yeo-Min
Song, Junghan
Ji, Misuk
Kim, Jeong-Ho
Kim, Yongkang
Park, Taesung
Song, Sang Hoon
Park, Seungman
Kim, Min Jin
Nho, Sun Jin
Oh, Kyung Won
Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015
title Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015
title_full Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015
title_fullStr Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015
title_full_unstemmed Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015
title_short Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015
title_sort calibration of high-density lipoprotein cholesterol values from the korea national health and nutrition examination survey data, 2008 to 2015
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5107612/
https://www.ncbi.nlm.nih.gov/pubmed/27834059
http://dx.doi.org/10.3343/alm.2017.37.1.1
work_keys_str_mv AT yunyeomin calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT songjunghan calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT jimisuk calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT kimjeongho calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT kimyongkang calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT parktaesung calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT songsanghoon calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT parkseungman calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT kimminjin calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT nhosunjin calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015
AT ohkyungwon calibrationofhighdensitylipoproteincholesterolvaluesfromthekoreanationalhealthandnutritionexaminationsurveydata2008to2015