Cargando…
Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor
[Image: see text] Introduction:Growing demands for ultrasensitive biosensing have led to the development of numerous signal amplification strategies. In this report, a novel electrochemiluminescence (ECL) method was developed for the detection and determination of caspase-3 activity based on reduced...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5108986/ https://www.ncbi.nlm.nih.gov/pubmed/27853677 http://dx.doi.org/10.15171/bi.2016.20 |
_version_ | 1782467455021481984 |
---|---|
author | Khalilzadeh, Balal Shadjou, Nasrin Afsharan, Hadi Eskandani, Morteza Nozad Charoudeh, Hojjatollah Rashidi, Mohammad-Reza |
author_facet | Khalilzadeh, Balal Shadjou, Nasrin Afsharan, Hadi Eskandani, Morteza Nozad Charoudeh, Hojjatollah Rashidi, Mohammad-Reza |
author_sort | Khalilzadeh, Balal |
collection | PubMed |
description | [Image: see text] Introduction:Growing demands for ultrasensitive biosensing have led to the development of numerous signal amplification strategies. In this report, a novel electrochemiluminescence (ECL) method was developed for the detection and determination of caspase-3 activity based on reduced graphene oxide sheets decorated by gold nanoparticles as signal amplification element and horseradish peroxidase enzyme (HRP) as ECL intensity enhancing agent. Methods: The ECL intensity of the luminol was improved by using the streptavidin coated magnetic beads and HRP in the presence of hydrogen peroxide. The cleavage behavior of caspase-3 was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using biotinylated peptide (DEVD containing peptide) which was coated on reduced graphene oxide decorated with gold nanoparticle. The surface modification of graphene oxide was successfully confirmed by FTIR, UV-vis and x-ray spectroscopy. Results: ECL based biosensor showed that the linear dynamic range (LDR) and the lower limit of quantification (LLOQ) were 0.5-100 and 0.5 femtomolar (fM), respectively. Finally, the performance of the engineered peptide based biosensor was validated in the A549 cell line as real samples. Conclusion: The prepared peptide based biosensor could be considered as an excellent candidate for early detection of apoptosis, cell turnover, and cancer related diseases. |
format | Online Article Text |
id | pubmed-5108986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-51089862016-11-16 Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor Khalilzadeh, Balal Shadjou, Nasrin Afsharan, Hadi Eskandani, Morteza Nozad Charoudeh, Hojjatollah Rashidi, Mohammad-Reza Bioimpacts Original Article [Image: see text] Introduction:Growing demands for ultrasensitive biosensing have led to the development of numerous signal amplification strategies. In this report, a novel electrochemiluminescence (ECL) method was developed for the detection and determination of caspase-3 activity based on reduced graphene oxide sheets decorated by gold nanoparticles as signal amplification element and horseradish peroxidase enzyme (HRP) as ECL intensity enhancing agent. Methods: The ECL intensity of the luminol was improved by using the streptavidin coated magnetic beads and HRP in the presence of hydrogen peroxide. The cleavage behavior of caspase-3 was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using biotinylated peptide (DEVD containing peptide) which was coated on reduced graphene oxide decorated with gold nanoparticle. The surface modification of graphene oxide was successfully confirmed by FTIR, UV-vis and x-ray spectroscopy. Results: ECL based biosensor showed that the linear dynamic range (LDR) and the lower limit of quantification (LLOQ) were 0.5-100 and 0.5 femtomolar (fM), respectively. Finally, the performance of the engineered peptide based biosensor was validated in the A549 cell line as real samples. Conclusion: The prepared peptide based biosensor could be considered as an excellent candidate for early detection of apoptosis, cell turnover, and cancer related diseases. Tabriz University of Medical Sciences 2016 2016-09-30 /pmc/articles/PMC5108986/ /pubmed/27853677 http://dx.doi.org/10.15171/bi.2016.20 Text en © 2016 The Author(s) This work is published by BioImpacts as an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc/4.0/). Non-commercial uses of the work are permitted, provided the original work is properly cited. |
spellingShingle | Original Article Khalilzadeh, Balal Shadjou, Nasrin Afsharan, Hadi Eskandani, Morteza Nozad Charoudeh, Hojjatollah Rashidi, Mohammad-Reza Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor |
title |
Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor
|
title_full |
Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor
|
title_fullStr |
Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor
|
title_full_unstemmed |
Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor
|
title_short |
Reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor
|
title_sort | reduced graphene oxide decorated with gold nanoparticle as signal amplification element on ultra-sensitive electrochemiluminescence determination of caspase-3 activity and apoptosis using peptide based biosensor |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5108986/ https://www.ncbi.nlm.nih.gov/pubmed/27853677 http://dx.doi.org/10.15171/bi.2016.20 |
work_keys_str_mv | AT khalilzadehbalal reducedgrapheneoxidedecoratedwithgoldnanoparticleassignalamplificationelementonultrasensitiveelectrochemiluminescencedeterminationofcaspase3activityandapoptosisusingpeptidebasedbiosensor AT shadjounasrin reducedgrapheneoxidedecoratedwithgoldnanoparticleassignalamplificationelementonultrasensitiveelectrochemiluminescencedeterminationofcaspase3activityandapoptosisusingpeptidebasedbiosensor AT afsharanhadi reducedgrapheneoxidedecoratedwithgoldnanoparticleassignalamplificationelementonultrasensitiveelectrochemiluminescencedeterminationofcaspase3activityandapoptosisusingpeptidebasedbiosensor AT eskandanimorteza reducedgrapheneoxidedecoratedwithgoldnanoparticleassignalamplificationelementonultrasensitiveelectrochemiluminescencedeterminationofcaspase3activityandapoptosisusingpeptidebasedbiosensor AT nozadcharoudehhojjatollah reducedgrapheneoxidedecoratedwithgoldnanoparticleassignalamplificationelementonultrasensitiveelectrochemiluminescencedeterminationofcaspase3activityandapoptosisusingpeptidebasedbiosensor AT rashidimohammadreza reducedgrapheneoxidedecoratedwithgoldnanoparticleassignalamplificationelementonultrasensitiveelectrochemiluminescencedeterminationofcaspase3activityandapoptosisusingpeptidebasedbiosensor |