Cargando…
The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis?
INTRODUCTION: In recent years, bioresorbable plates have undergone remarkable development. However, there has been no attendant improvement in their strength, because strength requires thickness, and complications such as palpability are related to the thickness of bioresorbable plate systems. In th...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5110331/ https://www.ncbi.nlm.nih.gov/pubmed/28005767 http://dx.doi.org/10.1097/SCS.0000000000003147 |
_version_ | 1782467677536649216 |
---|---|
author | Sukegawa, Shintaro Kanno, Takahiro Nagano, Daiki Shibata, Akane Sukegawa-Takahashi, Yuka Furuki, Yoshihiko |
author_facet | Sukegawa, Shintaro Kanno, Takahiro Nagano, Daiki Shibata, Akane Sukegawa-Takahashi, Yuka Furuki, Yoshihiko |
author_sort | Sukegawa, Shintaro |
collection | PubMed |
description | INTRODUCTION: In recent years, bioresorbable plates have undergone remarkable development. However, there has been no attendant improvement in their strength, because strength requires thickness, and complications such as palpability are related to the thickness of bioresorbable plate systems. In this clinical study, we compared the surgical management of zygomatic fractures using newly developed thinner bioresorbable materials or conventional titanium miniplates. METHODS: Twelve patients with zygomatic fractures were randomly divided equally into 2 groups (6 with new bioresorbable osteosynthesis materials and 6 with standard titanium miniplates). Using computed tomography, we evaluated the thickness of the soft tissue and plate at the zygomaticofrontal sutures in each patient with the help of detailed radiographic computed tomography data at 6 months postoperatively. We compared the amount of soft-tissue volume increase between the uninjured healthy and injured operated sides in each patient. RESULTS: Both groups eventually achieved satisfactory healing, with a favorable restoration of form and function and without any complications, including palpability. The amount of soft-tissue volume increase at the operated side relative to the uninjured healthy side using new thin bioresorbable plates was 131.1% (range: 101.5–165.8). On the other hand, that of titanium miniplates was 126.4% (range: 102.2–167.6). There was no statistically significant difference (P > 0.05). CONCLUSION: This newly developed thinner flat-type bioresorbable plate system could be considered clinically useful in the treatment of zygomatic fractures even in easily palpated areas, such as the infraorbital rim or zygomaticofrontal sutures, without any healing differences in skeleton as compared with conventional titanium miniplates. |
format | Online Article Text |
id | pubmed-5110331 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-51103312016-11-23 The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis? Sukegawa, Shintaro Kanno, Takahiro Nagano, Daiki Shibata, Akane Sukegawa-Takahashi, Yuka Furuki, Yoshihiko J Craniofac Surg Clinical Studies INTRODUCTION: In recent years, bioresorbable plates have undergone remarkable development. However, there has been no attendant improvement in their strength, because strength requires thickness, and complications such as palpability are related to the thickness of bioresorbable plate systems. In this clinical study, we compared the surgical management of zygomatic fractures using newly developed thinner bioresorbable materials or conventional titanium miniplates. METHODS: Twelve patients with zygomatic fractures were randomly divided equally into 2 groups (6 with new bioresorbable osteosynthesis materials and 6 with standard titanium miniplates). Using computed tomography, we evaluated the thickness of the soft tissue and plate at the zygomaticofrontal sutures in each patient with the help of detailed radiographic computed tomography data at 6 months postoperatively. We compared the amount of soft-tissue volume increase between the uninjured healthy and injured operated sides in each patient. RESULTS: Both groups eventually achieved satisfactory healing, with a favorable restoration of form and function and without any complications, including palpability. The amount of soft-tissue volume increase at the operated side relative to the uninjured healthy side using new thin bioresorbable plates was 131.1% (range: 101.5–165.8). On the other hand, that of titanium miniplates was 126.4% (range: 102.2–167.6). There was no statistically significant difference (P > 0.05). CONCLUSION: This newly developed thinner flat-type bioresorbable plate system could be considered clinically useful in the treatment of zygomatic fractures even in easily palpated areas, such as the infraorbital rim or zygomaticofrontal sutures, without any healing differences in skeleton as compared with conventional titanium miniplates. Lippincott Williams & Wilkins 2016-11 2016-10-14 /pmc/articles/PMC5110331/ /pubmed/28005767 http://dx.doi.org/10.1097/SCS.0000000000003147 Text en Copyright © 2016 by Mutaz B. Habal, MD http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | Clinical Studies Sukegawa, Shintaro Kanno, Takahiro Nagano, Daiki Shibata, Akane Sukegawa-Takahashi, Yuka Furuki, Yoshihiko The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis? |
title | The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis? |
title_full | The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis? |
title_fullStr | The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis? |
title_full_unstemmed | The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis? |
title_short | The Clinical Feasibility of Newly Developed Thin Flat-Type Bioresorbable Osteosynthesis Devices for the Internal Fixation of Zygomatic Fractures: Is There a Difference in Healing Between Bioresorbable Materials and Titanium Osteosynthesis? |
title_sort | clinical feasibility of newly developed thin flat-type bioresorbable osteosynthesis devices for the internal fixation of zygomatic fractures: is there a difference in healing between bioresorbable materials and titanium osteosynthesis? |
topic | Clinical Studies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5110331/ https://www.ncbi.nlm.nih.gov/pubmed/28005767 http://dx.doi.org/10.1097/SCS.0000000000003147 |
work_keys_str_mv | AT sukegawashintaro theclinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT kannotakahiro theclinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT naganodaiki theclinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT shibataakane theclinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT sukegawatakahashiyuka theclinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT furukiyoshihiko theclinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT sukegawashintaro clinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT kannotakahiro clinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT naganodaiki clinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT shibataakane clinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT sukegawatakahashiyuka clinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis AT furukiyoshihiko clinicalfeasibilityofnewlydevelopedthinflattypebioresorbableosteosynthesisdevicesfortheinternalfixationofzygomaticfracturesisthereadifferenceinhealingbetweenbioresorbablematerialsandtitaniumosteosynthesis |