BACKGROUND: Large tumor motion often leads to larger treatment volumes, especially the lung tumor located in lower lobe and adhered to chest wall or diaphragm. The purpose of this work is to investigate the impacts of planning target volume (PTV) margin on Stereotactic Body Radiotherapy (SBRT) in no...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yi, Ma, Jing-lu, Chen, Xin, Tang, Feng-wen, Zhang, Xiao-zhi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5111250/
https://www.ncbi.nlm.nih.gov/pubmed/27846900
http://dx.doi.org/10.1186/s13014-016-0724-5
_version_ 1782467831878647808
author Li, Yi
Ma, Jing-lu
Chen, Xin
Tang, Feng-wen
Zhang, Xiao-zhi
author_facet Li, Yi
Ma, Jing-lu
Chen, Xin
Tang, Feng-wen
Zhang, Xiao-zhi
author_sort Li, Yi
collection PubMed
description BACKGROUND: Large tumor motion often leads to larger treatment volumes, especially the lung tumor located in lower lobe and adhered to chest wall or diaphragm. The purpose of this work is to investigate the impacts of planning target volume (PTV) margin on Stereotactic Body Radiotherapy (SBRT) in non-small cell lung cancer (NSCLC). METHODS: Subjects include 20 patients with the lung tumor located in lower lobe and adhered to chest wall or diaphragm who underwent SBRT. Four-dimensional computed tomography (4DCT) were acquired at simulation to evaluate the tumor intra-fractional centroid and boundary changes, and Cone-beam Computer Tomography (CBCT) were acquired during each treatment to evaluate the tumor inter-fractional set-up displacement. The margin to compensate for tumor variations uncertainties was calculated with various margin calculated recipes published in the exiting literatures. RESULTS: The means (±standard deviation) of tumor centroid changes were 0.16 (±0.13) cm, 0.22 (±0.15) cm, and 1.37 (±0.81) cm in RL, AP, and SI directions, respectively. The means (±standard deviation) of tumor edge changes were 0.21 (±0.18) cm, 0.50 (±0.23) cm, and 0.19 (±0.44) cm in RL, AP, and SI directions, respectively. The means (±standard deviation) of tumor set-up displacement were 0.03 (±0.24) cm, 0.02 (±0.26) cm, and 0.02 (±0.43) cm in RL, AP, and SI directions, respectively. The PTV margin to compensate for lung cancer tumor variations uncertainties were 0.88, 0.98 and 2.68 cm in RL, AP and SI directions, which were maximal among all margin recipes. CONCLUSIONS: 4DCT and CBCT imaging are appropriate to account for the tumor intra-fractional centroid, boundary variations and inter-fractional set-up displacement. The PTV margin to compensate for lung cancer tumor variations uncertainties can be obtained. Our results show that a conventional 1.0 cm margin in the SI plane dose not suffice to compensate the geometrical variety of the tumor located in lower lobe and adhered to chest wall and diaphragm.
format Online
Article
Text
id pubmed-5111250
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-51112502016-11-25 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm Li, Yi Ma, Jing-lu Chen, Xin Tang, Feng-wen Zhang, Xiao-zhi Radiat Oncol Research BACKGROUND: Large tumor motion often leads to larger treatment volumes, especially the lung tumor located in lower lobe and adhered to chest wall or diaphragm. The purpose of this work is to investigate the impacts of planning target volume (PTV) margin on Stereotactic Body Radiotherapy (SBRT) in non-small cell lung cancer (NSCLC). METHODS: Subjects include 20 patients with the lung tumor located in lower lobe and adhered to chest wall or diaphragm who underwent SBRT. Four-dimensional computed tomography (4DCT) were acquired at simulation to evaluate the tumor intra-fractional centroid and boundary changes, and Cone-beam Computer Tomography (CBCT) were acquired during each treatment to evaluate the tumor inter-fractional set-up displacement. The margin to compensate for tumor variations uncertainties was calculated with various margin calculated recipes published in the exiting literatures. RESULTS: The means (±standard deviation) of tumor centroid changes were 0.16 (±0.13) cm, 0.22 (±0.15) cm, and 1.37 (±0.81) cm in RL, AP, and SI directions, respectively. The means (±standard deviation) of tumor edge changes were 0.21 (±0.18) cm, 0.50 (±0.23) cm, and 0.19 (±0.44) cm in RL, AP, and SI directions, respectively. The means (±standard deviation) of tumor set-up displacement were 0.03 (±0.24) cm, 0.02 (±0.26) cm, and 0.02 (±0.43) cm in RL, AP, and SI directions, respectively. The PTV margin to compensate for lung cancer tumor variations uncertainties were 0.88, 0.98 and 2.68 cm in RL, AP and SI directions, which were maximal among all margin recipes. CONCLUSIONS: 4DCT and CBCT imaging are appropriate to account for the tumor intra-fractional centroid, boundary variations and inter-fractional set-up displacement. The PTV margin to compensate for lung cancer tumor variations uncertainties can be obtained. Our results show that a conventional 1.0 cm margin in the SI plane dose not suffice to compensate the geometrical variety of the tumor located in lower lobe and adhered to chest wall and diaphragm. BioMed Central 2016-11-15 /pmc/articles/PMC5111250/ /pubmed/27846900 http://dx.doi.org/10.1186/s13014-016-0724-5 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Li, Yi
Ma, Jing-lu
Chen, Xin
Tang, Feng-wen
Zhang, Xiao-zhi
4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
title 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
title_full 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
title_fullStr 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
title_full_unstemmed 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
title_short 4DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
title_sort 4dct and cbct based ptv margin in stereotactic body radiotherapy(sbrt) of non-small cell lung tumor adhered to chest wall or diaphragm
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5111250/
https://www.ncbi.nlm.nih.gov/pubmed/27846900
http://dx.doi.org/10.1186/s13014-016-0724-5
work_keys_str_mv AT liyi 4dctandcbctbasedptvmargininstereotacticbodyradiotherapysbrtofnonsmallcelllungtumoradheredtochestwallordiaphragm
AT majinglu 4dctandcbctbasedptvmargininstereotacticbodyradiotherapysbrtofnonsmallcelllungtumoradheredtochestwallordiaphragm
AT chenxin 4dctandcbctbasedptvmargininstereotacticbodyradiotherapysbrtofnonsmallcelllungtumoradheredtochestwallordiaphragm
AT tangfengwen 4dctandcbctbasedptvmargininstereotacticbodyradiotherapysbrtofnonsmallcelllungtumoradheredtochestwallordiaphragm
AT zhangxiaozhi 4dctandcbctbasedptvmargininstereotacticbodyradiotherapysbrtofnonsmallcelllungtumoradheredtochestwallordiaphragm