Cargando…

Accelerating in vitro studies on circadian clock systems using an automated sampling device

KaiC, a core protein of the cyanobacterial circadian clock, is rhythmically autophosphorylated and autodephosphorylated with a period of approximately 24 h in the presence of two other Kai proteins, KaiA and KaiB. In vitro experiments to investigate the KaiC phosphorylation cycle consume considerabl...

Descripción completa

Detalles Bibliográficos
Autores principales: Furuike, Yoshihiko, Abe, Jun, Mukaiyama, Atsushi, Akiyama, Shuji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Biophysical Society of Japan (BSJ) 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5113610/
https://www.ncbi.nlm.nih.gov/pubmed/27924279
http://dx.doi.org/10.2142/biophysico.13.0_235
_version_ 1782468218181386240
author Furuike, Yoshihiko
Abe, Jun
Mukaiyama, Atsushi
Akiyama, Shuji
author_facet Furuike, Yoshihiko
Abe, Jun
Mukaiyama, Atsushi
Akiyama, Shuji
author_sort Furuike, Yoshihiko
collection PubMed
description KaiC, a core protein of the cyanobacterial circadian clock, is rhythmically autophosphorylated and autodephosphorylated with a period of approximately 24 h in the presence of two other Kai proteins, KaiA and KaiB. In vitro experiments to investigate the KaiC phosphorylation cycle consume considerable time and effort. To automate the fractionation, quantification, and evaluation steps, we developed a suite consisting of an automated sampling device equipped with an 8-channel temperature controller and accompanying analysis software. Eight sample tables can be controlled independently at different temperatures within a fluctuation of ±0.01°C, enabling investigation of the temperature dependency of clock activities simultaneously in a single experiment. The suite includes an independent software that helps users intuitively conduct a densitometric analysis of gel images in a short time with improved reliability. Multiple lanes on a gel can be detected quasi-automatically through an auto-detection procedure implemented in the software, with or without correction for lane ‘smiling.’ To demonstrate the performance of the suite, robustness of the period against temperature variations was evaluated using 32 datasets of the KaiC phosphorylation cycle. By using the software, the time required for the analysis was reduced by approximately 65% relative to the conventional method, with reasonable reproducibility and quality. The suite is potentially applicable to other clock or clock-related systems in higher organisms, relieving users from having to repeat multiple manual sampling and analytical steps.
format Online
Article
Text
id pubmed-5113610
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Biophysical Society of Japan (BSJ)
record_format MEDLINE/PubMed
spelling pubmed-51136102016-12-06 Accelerating in vitro studies on circadian clock systems using an automated sampling device Furuike, Yoshihiko Abe, Jun Mukaiyama, Atsushi Akiyama, Shuji Biophys Physicobiol Experimental Method and Protocol KaiC, a core protein of the cyanobacterial circadian clock, is rhythmically autophosphorylated and autodephosphorylated with a period of approximately 24 h in the presence of two other Kai proteins, KaiA and KaiB. In vitro experiments to investigate the KaiC phosphorylation cycle consume considerable time and effort. To automate the fractionation, quantification, and evaluation steps, we developed a suite consisting of an automated sampling device equipped with an 8-channel temperature controller and accompanying analysis software. Eight sample tables can be controlled independently at different temperatures within a fluctuation of ±0.01°C, enabling investigation of the temperature dependency of clock activities simultaneously in a single experiment. The suite includes an independent software that helps users intuitively conduct a densitometric analysis of gel images in a short time with improved reliability. Multiple lanes on a gel can be detected quasi-automatically through an auto-detection procedure implemented in the software, with or without correction for lane ‘smiling.’ To demonstrate the performance of the suite, robustness of the period against temperature variations was evaluated using 32 datasets of the KaiC phosphorylation cycle. By using the software, the time required for the analysis was reduced by approximately 65% relative to the conventional method, with reasonable reproducibility and quality. The suite is potentially applicable to other clock or clock-related systems in higher organisms, relieving users from having to repeat multiple manual sampling and analytical steps. The Biophysical Society of Japan (BSJ) 2016-10-26 /pmc/articles/PMC5113610/ /pubmed/27924279 http://dx.doi.org/10.2142/biophysico.13.0_235 Text en © 2016 The Biophysical Society of Japan This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Experimental Method and Protocol
Furuike, Yoshihiko
Abe, Jun
Mukaiyama, Atsushi
Akiyama, Shuji
Accelerating in vitro studies on circadian clock systems using an automated sampling device
title Accelerating in vitro studies on circadian clock systems using an automated sampling device
title_full Accelerating in vitro studies on circadian clock systems using an automated sampling device
title_fullStr Accelerating in vitro studies on circadian clock systems using an automated sampling device
title_full_unstemmed Accelerating in vitro studies on circadian clock systems using an automated sampling device
title_short Accelerating in vitro studies on circadian clock systems using an automated sampling device
title_sort accelerating in vitro studies on circadian clock systems using an automated sampling device
topic Experimental Method and Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5113610/
https://www.ncbi.nlm.nih.gov/pubmed/27924279
http://dx.doi.org/10.2142/biophysico.13.0_235
work_keys_str_mv AT furuikeyoshihiko acceleratinginvitrostudiesoncircadianclocksystemsusinganautomatedsamplingdevice
AT abejun acceleratinginvitrostudiesoncircadianclocksystemsusinganautomatedsamplingdevice
AT mukaiyamaatsushi acceleratinginvitrostudiesoncircadianclocksystemsusinganautomatedsamplingdevice
AT akiyamashuji acceleratinginvitrostudiesoncircadianclocksystemsusinganautomatedsamplingdevice