Cargando…
Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance,...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Brain Tumor Society; The Korean Society for Neuro-Oncology; The Korean Society for Pediatric Neuro-Oncology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5114189/ https://www.ncbi.nlm.nih.gov/pubmed/27867929 http://dx.doi.org/10.14791/btrt.2016.4.2.150 |
_version_ | 1782468301965754368 |
---|---|
author | Moon, Hyeong Cheol Baek, Hyeon-Man Park, Young Seok |
author_facet | Moon, Hyeong Cheol Baek, Hyeon-Man Park, Young Seok |
author_sort | Moon, Hyeong Cheol |
collection | PubMed |
description | Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance, hormonal insufficiency, and urinary incontinence that began prior to 6 years of age. 3.0T MRI revealed a non-enhancing tectal mass along with obstructive hydrocephalus. The mass measured approximately 1.1×1.0×1.2 cm. An endoscopic third ventriculostomy was performed to relieve the hydrocephalus. We compared hydrocephalus and cerebrospinal fluid (CSF) flow findings from 3T and 7T MRI, both preoperative and postoperative at 1, 6 months. Intraventricular CSF voiding on T2-weighted images obtained with 7T MRI showed greater fluid inversion than those obtained with 3T MRI. This study shows that 7T brain MRI can provide detailed information on hydrocephalus caused by tectal glioma. Further studies are needed to develop refined 7T MRI protocols for better images of hydrocephalus. |
format | Online Article Text |
id | pubmed-5114189 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Brain Tumor Society; The Korean Society for Neuro-Oncology; The Korean Society for Pediatric Neuro-Oncology |
record_format | MEDLINE/PubMed |
spelling | pubmed-51141892016-11-19 Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma Moon, Hyeong Cheol Baek, Hyeon-Man Park, Young Seok Brain Tumor Res Treat Case Report Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance, hormonal insufficiency, and urinary incontinence that began prior to 6 years of age. 3.0T MRI revealed a non-enhancing tectal mass along with obstructive hydrocephalus. The mass measured approximately 1.1×1.0×1.2 cm. An endoscopic third ventriculostomy was performed to relieve the hydrocephalus. We compared hydrocephalus and cerebrospinal fluid (CSF) flow findings from 3T and 7T MRI, both preoperative and postoperative at 1, 6 months. Intraventricular CSF voiding on T2-weighted images obtained with 7T MRI showed greater fluid inversion than those obtained with 3T MRI. This study shows that 7T brain MRI can provide detailed information on hydrocephalus caused by tectal glioma. Further studies are needed to develop refined 7T MRI protocols for better images of hydrocephalus. The Korean Brain Tumor Society; The Korean Society for Neuro-Oncology; The Korean Society for Pediatric Neuro-Oncology 2016-10 2016-10-31 /pmc/articles/PMC5114189/ /pubmed/27867929 http://dx.doi.org/10.14791/btrt.2016.4.2.150 Text en Copyright © 2016 The Korean Brain Tumor Society, The Korean Society for Neuro-Oncology, and The Korean Society for Pediatric Neuro-Oncology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Moon, Hyeong Cheol Baek, Hyeon-Man Park, Young Seok Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma |
title | Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma |
title_full | Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma |
title_fullStr | Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma |
title_full_unstemmed | Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma |
title_short | Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma |
title_sort | comparison of 3 and 7 tesla magnetic resonance imaging of obstructive hydrocephalus caused by tectal glioma |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5114189/ https://www.ncbi.nlm.nih.gov/pubmed/27867929 http://dx.doi.org/10.14791/btrt.2016.4.2.150 |
work_keys_str_mv | AT moonhyeongcheol comparisonof3and7teslamagneticresonanceimagingofobstructivehydrocephaluscausedbytectalglioma AT baekhyeonman comparisonof3and7teslamagneticresonanceimagingofobstructivehydrocephaluscausedbytectalglioma AT parkyoungseok comparisonof3and7teslamagneticresonanceimagingofobstructivehydrocephaluscausedbytectalglioma |