Cargando…

Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma

Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance,...

Descripción completa

Detalles Bibliográficos
Autores principales: Moon, Hyeong Cheol, Baek, Hyeon-Man, Park, Young Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Brain Tumor Society; The Korean Society for Neuro-Oncology; The Korean Society for Pediatric Neuro-Oncology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5114189/
https://www.ncbi.nlm.nih.gov/pubmed/27867929
http://dx.doi.org/10.14791/btrt.2016.4.2.150
_version_ 1782468301965754368
author Moon, Hyeong Cheol
Baek, Hyeon-Man
Park, Young Seok
author_facet Moon, Hyeong Cheol
Baek, Hyeon-Man
Park, Young Seok
author_sort Moon, Hyeong Cheol
collection PubMed
description Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance, hormonal insufficiency, and urinary incontinence that began prior to 6 years of age. 3.0T MRI revealed a non-enhancing tectal mass along with obstructive hydrocephalus. The mass measured approximately 1.1×1.0×1.2 cm. An endoscopic third ventriculostomy was performed to relieve the hydrocephalus. We compared hydrocephalus and cerebrospinal fluid (CSF) flow findings from 3T and 7T MRI, both preoperative and postoperative at 1, 6 months. Intraventricular CSF voiding on T2-weighted images obtained with 7T MRI showed greater fluid inversion than those obtained with 3T MRI. This study shows that 7T brain MRI can provide detailed information on hydrocephalus caused by tectal glioma. Further studies are needed to develop refined 7T MRI protocols for better images of hydrocephalus.
format Online
Article
Text
id pubmed-5114189
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Brain Tumor Society; The Korean Society for Neuro-Oncology; The Korean Society for Pediatric Neuro-Oncology
record_format MEDLINE/PubMed
spelling pubmed-51141892016-11-19 Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma Moon, Hyeong Cheol Baek, Hyeon-Man Park, Young Seok Brain Tumor Res Treat Case Report Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance, hormonal insufficiency, and urinary incontinence that began prior to 6 years of age. 3.0T MRI revealed a non-enhancing tectal mass along with obstructive hydrocephalus. The mass measured approximately 1.1×1.0×1.2 cm. An endoscopic third ventriculostomy was performed to relieve the hydrocephalus. We compared hydrocephalus and cerebrospinal fluid (CSF) flow findings from 3T and 7T MRI, both preoperative and postoperative at 1, 6 months. Intraventricular CSF voiding on T2-weighted images obtained with 7T MRI showed greater fluid inversion than those obtained with 3T MRI. This study shows that 7T brain MRI can provide detailed information on hydrocephalus caused by tectal glioma. Further studies are needed to develop refined 7T MRI protocols for better images of hydrocephalus. The Korean Brain Tumor Society; The Korean Society for Neuro-Oncology; The Korean Society for Pediatric Neuro-Oncology 2016-10 2016-10-31 /pmc/articles/PMC5114189/ /pubmed/27867929 http://dx.doi.org/10.14791/btrt.2016.4.2.150 Text en Copyright © 2016 The Korean Brain Tumor Society, The Korean Society for Neuro-Oncology, and The Korean Society for Pediatric Neuro-Oncology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Moon, Hyeong Cheol
Baek, Hyeon-Man
Park, Young Seok
Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
title Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
title_full Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
title_fullStr Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
title_full_unstemmed Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
title_short Comparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
title_sort comparison of 3 and 7 tesla magnetic resonance imaging of obstructive hydrocephalus caused by tectal glioma
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5114189/
https://www.ncbi.nlm.nih.gov/pubmed/27867929
http://dx.doi.org/10.14791/btrt.2016.4.2.150
work_keys_str_mv AT moonhyeongcheol comparisonof3and7teslamagneticresonanceimagingofobstructivehydrocephaluscausedbytectalglioma
AT baekhyeonman comparisonof3and7teslamagneticresonanceimagingofobstructivehydrocephaluscausedbytectalglioma
AT parkyoungseok comparisonof3and7teslamagneticresonanceimagingofobstructivehydrocephaluscausedbytectalglioma