Prediction of fluid responsiveness: an update

In patients with acute circulatory failure, the decision to give fluids or not should not be taken lightly. The risk of overzealous fluid administration has been clearly established. Moreover, volume expansion does not always increase cardiac output as one expects. Thus, after the very initial phase...

Descripción completa

Detalles Bibliográficos
Autores principales: Monnet, Xavier, Marik, Paul E., Teboul, Jean-Louis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5114218/
https://www.ncbi.nlm.nih.gov/pubmed/27858374
http://dx.doi.org/10.1186/s13613-016-0216-7
_version_ 1782468308580171776
author Monnet, Xavier
Marik, Paul E.
Teboul, Jean-Louis
author_facet Monnet, Xavier
Marik, Paul E.
Teboul, Jean-Louis
author_sort Monnet, Xavier
collection PubMed
description In patients with acute circulatory failure, the decision to give fluids or not should not be taken lightly. The risk of overzealous fluid administration has been clearly established. Moreover, volume expansion does not always increase cardiac output as one expects. Thus, after the very initial phase and/or if fluid losses are not obvious, predicting fluid responsiveness should be the first step of fluid strategy. For this purpose, the central venous pressure as well as other “static” markers of preload has been used for decades, but they are not reliable. Robust evidence suggests that this traditional use should be abandoned. Over the last 15 years, a number of dynamic tests have been developed. These tests are based on the principle of inducing short-term changes in cardiac preload, using heart–lung interactions, the passive leg raise or by the infusion of small volumes of fluid, and to observe the resulting effect on cardiac output. Pulse pressure and stroke volume variations were first developed, but they are reliable only under strict conditions. The variations in vena caval diameters share many limitations of pulse pressure variations. The passive leg-raising test is now supported by solid evidence and is more frequently used. More recently, the end-expiratory occlusion test has been described, which is easily performed in ventilated patients. Unlike the traditional fluid challenge, these dynamic tests do not lead to fluid overload. The dynamic tests are complementary, and clinicians should choose between them based on the status of the patient and the cardiac output monitoring technique. Several methods and tests are currently available to identify preload responsiveness. All have some limitations, but they are frequently complementary. Along with elements indicating the risk of fluid administration, they should help clinicians to take the decision to administer fluids or not in a reasoned way.
format Online
Article
Text
id pubmed-5114218
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-51142182016-12-02 Prediction of fluid responsiveness: an update Monnet, Xavier Marik, Paul E. Teboul, Jean-Louis Ann Intensive Care Review In patients with acute circulatory failure, the decision to give fluids or not should not be taken lightly. The risk of overzealous fluid administration has been clearly established. Moreover, volume expansion does not always increase cardiac output as one expects. Thus, after the very initial phase and/or if fluid losses are not obvious, predicting fluid responsiveness should be the first step of fluid strategy. For this purpose, the central venous pressure as well as other “static” markers of preload has been used for decades, but they are not reliable. Robust evidence suggests that this traditional use should be abandoned. Over the last 15 years, a number of dynamic tests have been developed. These tests are based on the principle of inducing short-term changes in cardiac preload, using heart–lung interactions, the passive leg raise or by the infusion of small volumes of fluid, and to observe the resulting effect on cardiac output. Pulse pressure and stroke volume variations were first developed, but they are reliable only under strict conditions. The variations in vena caval diameters share many limitations of pulse pressure variations. The passive leg-raising test is now supported by solid evidence and is more frequently used. More recently, the end-expiratory occlusion test has been described, which is easily performed in ventilated patients. Unlike the traditional fluid challenge, these dynamic tests do not lead to fluid overload. The dynamic tests are complementary, and clinicians should choose between them based on the status of the patient and the cardiac output monitoring technique. Several methods and tests are currently available to identify preload responsiveness. All have some limitations, but they are frequently complementary. Along with elements indicating the risk of fluid administration, they should help clinicians to take the decision to administer fluids or not in a reasoned way. Springer Paris 2016-11-17 /pmc/articles/PMC5114218/ /pubmed/27858374 http://dx.doi.org/10.1186/s13613-016-0216-7 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review
Monnet, Xavier
Marik, Paul E.
Teboul, Jean-Louis
Prediction of fluid responsiveness: an update
title Prediction of fluid responsiveness: an update
title_full Prediction of fluid responsiveness: an update
title_fullStr Prediction of fluid responsiveness: an update
title_full_unstemmed Prediction of fluid responsiveness: an update
title_short Prediction of fluid responsiveness: an update
title_sort prediction of fluid responsiveness: an update
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5114218/
https://www.ncbi.nlm.nih.gov/pubmed/27858374
http://dx.doi.org/10.1186/s13613-016-0216-7
work_keys_str_mv AT monnetxavier predictionoffluidresponsivenessanupdate
AT marikpaule predictionoffluidresponsivenessanupdate
AT tebouljeanlouis predictionoffluidresponsivenessanupdate