Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE)
BACKGROUND: Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonome...
Autores principales: | Shen, Yang, Su, Xiangjian, Liu, Xiu, Miao, Huamao, Fang, Xuejun, Zhou, Xingtao |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5116167/ https://www.ncbi.nlm.nih.gov/pubmed/27863469 http://dx.doi.org/10.1186/s12886-016-0381-3 |
Ejemplares similares
-
Evaluation of biomechanically corrected intraocular pressure using Corvis ST and comparison of the Corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma
por: Nakao, Yoshitaka, et al.
Publicado: (2020) -
Evaluation of Corneal Biomechanical Properties Modification after Small Incision Lenticule Extraction Using Scheimpflug-Based Noncontact Tonometer
por: Mastropasqua, Leonardo, et al.
Publicado: (2014) -
Comparison of intraocular pressure measurement with Scheimpflug-based noncontact tonometer with and without hydrogel contact lenses
por: Kumar, Mukesh, et al.
Publicado: (2015) -
Comparison of Goldmann applanation tonometer, Tono-Pen and noncontact tonometer in children
por: Raina, Usha Kaul, et al.
Publicado: (2016) -
Selected parameters of the corneal deformation in the Corvis tonometer
por: Koprowski, Robert, et al.
Publicado: (2014)