Cargando…
Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus
OBJECTIVES: To evaluate morphologic variations at the aortic isthmus with particular attention to ductus diverticulum, a mimicker of traumatic pseudoaneurysm, and to describe differences using Computed Tomography (CT) images. PATIENTS AND METHODS: From December 2013 to December 2014, patients who un...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5118843/ https://www.ncbi.nlm.nih.gov/pubmed/27895881 http://dx.doi.org/10.5812/iranjradiol.38016 |
_version_ | 1782469003941249024 |
---|---|
author | Hyung Ann, Jun Young Kim, Eun Mi Jeong, Yu Ho Kim, Jeong Sik Kim, Hyung Choi, Hye-Young |
author_facet | Hyung Ann, Jun Young Kim, Eun Mi Jeong, Yu Ho Kim, Jeong Sik Kim, Hyung Choi, Hye-Young |
author_sort | Hyung Ann, Jun |
collection | PubMed |
description | OBJECTIVES: To evaluate morphologic variations at the aortic isthmus with particular attention to ductus diverticulum, a mimicker of traumatic pseudoaneurysm, and to describe differences using Computed Tomography (CT) images. PATIENTS AND METHODS: From December 2013 to December 2014, patients who underwent a chest CT examination after blunt trauma at our emergency department were included. Aortic isthmus morphologies were evaluated using multiplanar reconstruction (MPR) and maximum intensity projection (MIP) images as follows. Type I -concave contour, type II -convexity without a discrete bulge, or type III -a discrete focal bulge (defined as ductus diverticulum). RESULTS: After excluding 11 cases of traumatic pseudoaneurysm of the aortic isthmus, a total of 432 trauma patients (mean age = 47.1 ± 19.1 years, number of males = 318) were evaluated for aortic isthmus morphology, and classified as follows; type I (n = 240, 55.6%), type II (n = 157, 36.3%), and type III (n = 35, 8.1%). As compared with traumatic pseudoaneurysm (n = 11), ductus diverticulum had a smaller vertical diameter (5.5 ± 1.3 mm vs. 11.2 ± 2.7 mm, P < 0.001), a broader base (14.9 ± 4.1 mm vs. 8.8 ± 4.5 mm, P < 0.001), a smoother margin (97.1% vs. 27.3%, P < 0.001), and formed obtuse angle with the aortic wall. Furthermore, ductus diverticulum was not associated with the presence of a dissection flap or hemomediastinum. CONCLUSION: Ductus diverticulum, a mimicker of traumatic pseudoaneurysm of the aortic isthmus, is a frequently observed anatomic variant during CT examinations. Familiarity with its CT imaging findings could avoid it being confused with traumatic pseudoaneurysm in blunt trauma patients. |
format | Online Article Text |
id | pubmed-5118843 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-51188432016-11-28 Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus Hyung Ann, Jun Young Kim, Eun Mi Jeong, Yu Ho Kim, Jeong Sik Kim, Hyung Choi, Hye-Young Iran J Radiol Vascular & Interventional Radiology OBJECTIVES: To evaluate morphologic variations at the aortic isthmus with particular attention to ductus diverticulum, a mimicker of traumatic pseudoaneurysm, and to describe differences using Computed Tomography (CT) images. PATIENTS AND METHODS: From December 2013 to December 2014, patients who underwent a chest CT examination after blunt trauma at our emergency department were included. Aortic isthmus morphologies were evaluated using multiplanar reconstruction (MPR) and maximum intensity projection (MIP) images as follows. Type I -concave contour, type II -convexity without a discrete bulge, or type III -a discrete focal bulge (defined as ductus diverticulum). RESULTS: After excluding 11 cases of traumatic pseudoaneurysm of the aortic isthmus, a total of 432 trauma patients (mean age = 47.1 ± 19.1 years, number of males = 318) were evaluated for aortic isthmus morphology, and classified as follows; type I (n = 240, 55.6%), type II (n = 157, 36.3%), and type III (n = 35, 8.1%). As compared with traumatic pseudoaneurysm (n = 11), ductus diverticulum had a smaller vertical diameter (5.5 ± 1.3 mm vs. 11.2 ± 2.7 mm, P < 0.001), a broader base (14.9 ± 4.1 mm vs. 8.8 ± 4.5 mm, P < 0.001), a smoother margin (97.1% vs. 27.3%, P < 0.001), and formed obtuse angle with the aortic wall. Furthermore, ductus diverticulum was not associated with the presence of a dissection flap or hemomediastinum. CONCLUSION: Ductus diverticulum, a mimicker of traumatic pseudoaneurysm of the aortic isthmus, is a frequently observed anatomic variant during CT examinations. Familiarity with its CT imaging findings could avoid it being confused with traumatic pseudoaneurysm in blunt trauma patients. Kowsar 2016-08-01 /pmc/articles/PMC5118843/ /pubmed/27895881 http://dx.doi.org/10.5812/iranjradiol.38016 Text en Copyright © 2016, Tehran University of Medical Sciences and Iranian Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Vascular & Interventional Radiology Hyung Ann, Jun Young Kim, Eun Mi Jeong, Yu Ho Kim, Jeong Sik Kim, Hyung Choi, Hye-Young Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus |
title | Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus |
title_full | Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus |
title_fullStr | Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus |
title_full_unstemmed | Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus |
title_short | Morphologic Evaluation of Ductus Diverticulum Using Multi - Detector Computed Tomography: Comparison with Traumatic Pseudoaneurysm of the Aortic Isthmus |
title_sort | morphologic evaluation of ductus diverticulum using multi - detector computed tomography: comparison with traumatic pseudoaneurysm of the aortic isthmus |
topic | Vascular & Interventional Radiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5118843/ https://www.ncbi.nlm.nih.gov/pubmed/27895881 http://dx.doi.org/10.5812/iranjradiol.38016 |
work_keys_str_mv | AT hyungannjun morphologicevaluationofductusdiverticulumusingmultidetectorcomputedtomographycomparisonwithtraumaticpseudoaneurysmoftheaorticisthmus AT youngkimeun morphologicevaluationofductusdiverticulumusingmultidetectorcomputedtomographycomparisonwithtraumaticpseudoaneurysmoftheaorticisthmus AT mijeongyu morphologicevaluationofductusdiverticulumusingmultidetectorcomputedtomographycomparisonwithtraumaticpseudoaneurysmoftheaorticisthmus AT hokimjeong morphologicevaluationofductusdiverticulumusingmultidetectorcomputedtomographycomparisonwithtraumaticpseudoaneurysmoftheaorticisthmus AT sikkimhyung morphologicevaluationofductusdiverticulumusingmultidetectorcomputedtomographycomparisonwithtraumaticpseudoaneurysmoftheaorticisthmus AT choihyeyoung morphologicevaluationofductusdiverticulumusingmultidetectorcomputedtomographycomparisonwithtraumaticpseudoaneurysmoftheaorticisthmus |