Cargando…

Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin

BACKGROUND: Coronary angiography (CAG) is widely used to assess lumen dimensions, and optical coherence tomography (OCT) is used to evaluate the characteristics of atherosclerotic plaque. This study was aimed to compare coronary lumen dimensions using CAG and plaque characteristics using OCT and the...

Descripción completa

Detalles Bibliográficos
Autores principales: Dong, Nana, Xie, Zulong, Wang, Wei, Dai, Jiannan, Sun, Meng, Pu, Zhongyue, Tian, Jinwei, Yu, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5118892/
https://www.ncbi.nlm.nih.gov/pubmed/27871242
http://dx.doi.org/10.1186/s12880-016-0166-4
_version_ 1782469013739143168
author Dong, Nana
Xie, Zulong
Wang, Wei
Dai, Jiannan
Sun, Meng
Pu, Zhongyue
Tian, Jinwei
Yu, Bo
author_facet Dong, Nana
Xie, Zulong
Wang, Wei
Dai, Jiannan
Sun, Meng
Pu, Zhongyue
Tian, Jinwei
Yu, Bo
author_sort Dong, Nana
collection PubMed
description BACKGROUND: Coronary angiography (CAG) is widely used to assess lumen dimensions, and optical coherence tomography (OCT) is used to evaluate the characteristics of atherosclerotic plaque. This study was aimed to compare coronary lumen dimensions using CAG and plaque characteristics using OCT and their changes during statin therapy. METHODS: We identified 97 lipid-rich plaques from 69 statin-naïve patients, who received statin therapy in the following 12 months. CAG and OCT examinations were conducted at baseline and 12-month follow-up period. RESULTS: Lesion length, as measured by CAG, was closely correlated with lipid length by OCT (baseline: r = 0.754, p < 0.001; follow-up: r = 0.639, p < 0.001). However, no significant correlations were found between the other findings on OCT and data on CAG. With 12-month statin therapy, microstructures of lipid-rich plaques were significantly improved, but CAG-derived lumen dimensions were not improved. Moreover, we found no significant relationship between changes in OCT measurements and changes in CAG data over time. CONCLUSION: Lipid length on OCT and lesion length on CAG were closely correlated. However, plaque microstructural characteristics on OCT showed no significantly statistically correlations with lumen dimensions on CAG, neither did their evolutionary changes induced by statin over time. A RETROSPECTIVELY REGISTERED STUDY: Clinical trial registry: ClinicalTrial.gov. Registered number: NCT01023607. Registered 1 December 2009.
format Online
Article
Text
id pubmed-5118892
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-51188922016-11-28 Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin Dong, Nana Xie, Zulong Wang, Wei Dai, Jiannan Sun, Meng Pu, Zhongyue Tian, Jinwei Yu, Bo BMC Med Imaging Research Article BACKGROUND: Coronary angiography (CAG) is widely used to assess lumen dimensions, and optical coherence tomography (OCT) is used to evaluate the characteristics of atherosclerotic plaque. This study was aimed to compare coronary lumen dimensions using CAG and plaque characteristics using OCT and their changes during statin therapy. METHODS: We identified 97 lipid-rich plaques from 69 statin-naïve patients, who received statin therapy in the following 12 months. CAG and OCT examinations were conducted at baseline and 12-month follow-up period. RESULTS: Lesion length, as measured by CAG, was closely correlated with lipid length by OCT (baseline: r = 0.754, p < 0.001; follow-up: r = 0.639, p < 0.001). However, no significant correlations were found between the other findings on OCT and data on CAG. With 12-month statin therapy, microstructures of lipid-rich plaques were significantly improved, but CAG-derived lumen dimensions were not improved. Moreover, we found no significant relationship between changes in OCT measurements and changes in CAG data over time. CONCLUSION: Lipid length on OCT and lesion length on CAG were closely correlated. However, plaque microstructural characteristics on OCT showed no significantly statistically correlations with lumen dimensions on CAG, neither did their evolutionary changes induced by statin over time. A RETROSPECTIVELY REGISTERED STUDY: Clinical trial registry: ClinicalTrial.gov. Registered number: NCT01023607. Registered 1 December 2009. BioMed Central 2016-11-22 /pmc/articles/PMC5118892/ /pubmed/27871242 http://dx.doi.org/10.1186/s12880-016-0166-4 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Dong, Nana
Xie, Zulong
Wang, Wei
Dai, Jiannan
Sun, Meng
Pu, Zhongyue
Tian, Jinwei
Yu, Bo
Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
title Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
title_full Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
title_fullStr Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
title_full_unstemmed Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
title_short Comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
title_sort comparison of coronary arterial lumen dimensions on angiography and plaque characteristics on optical coherence tomography images and their changes induced by statin
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5118892/
https://www.ncbi.nlm.nih.gov/pubmed/27871242
http://dx.doi.org/10.1186/s12880-016-0166-4
work_keys_str_mv AT dongnana comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin
AT xiezulong comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin
AT wangwei comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin
AT daijiannan comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin
AT sunmeng comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin
AT puzhongyue comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin
AT tianjinwei comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin
AT yubo comparisonofcoronaryarteriallumendimensionsonangiographyandplaquecharacteristicsonopticalcoherencetomographyimagesandtheirchangesinducedbystatin