Cargando…
The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography
BACKGROUND: Changes in head and neck anatomy during radiation therapy (RT) produce setup uncertainties of nasopharyngeal cancer (NPC) irradiation. We retrospectively analyzed image guidance data to identify clinical predictors of setup errors. PATIENTS AND METHODS: The data of 217 NPC patients under...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
De Gruyter
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5120582/ https://www.ncbi.nlm.nih.gov/pubmed/27904451 http://dx.doi.org/10.1515/raon-2016-0047 |
_version_ | 1782469269611610112 |
---|---|
author | Hou, Wei-Hsien Wang, Chun-Wei Tsai, Chiao-Ling Hsu, Feng-Ming Cheng, Jason Chia-Hsien |
author_facet | Hou, Wei-Hsien Wang, Chun-Wei Tsai, Chiao-Ling Hsu, Feng-Ming Cheng, Jason Chia-Hsien |
author_sort | Hou, Wei-Hsien |
collection | PubMed |
description | BACKGROUND: Changes in head and neck anatomy during radiation therapy (RT) produce setup uncertainties of nasopharyngeal cancer (NPC) irradiation. We retrospectively analyzed image guidance data to identify clinical predictors of setup errors. PATIENTS AND METHODS: The data of 217 NPC patients undergoing definitive RT on a helical tomotherapy (HT) unit were analyzed. Factors including tumor stage, body mass index, weight loss, and planning target volume (PTV) were assessed as predictors of daily megavoltage computed tomography (MVCT) setup displacements, which were automatically registered using software. RESULTS: Mean daily setup displacements (in mm) were 1.2 ± 0.6, 1.8 ± 0.8, 3.4 ± 1.4 in the medial-lateral (ML), superior-inferior (SI), and anterior-posterior (AP) directions, respectively. Mean weight loss was 4.6 ± 3.3 kg (6.8 ± 4.9%). Patients with weight loss > 5% had significantly larger setup displacements in the AP (3.6 ± 1.5 vs. 2.9 ± 1.1 mm, p < 0.001) and SI (1.6 ± 0.7 vs. 1.9 ± 0.9 mm, p = 0.01) direction, but not in the ML direction (p = 0.279). The AP setup error increased 0.06 mm (y = 0.055x + 2.927, x: percentage of weight loss/PTV, y: AP displacement) per one percent increase in weight loss normalized to PTV. CONCLUSIONS: Patients with weight loss > 5% and smaller PTVs, possibly because of small body frame or neck girth, were more likely to have increased setup errors in the AP direction. |
format | Online Article Text |
id | pubmed-5120582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | De Gruyter |
record_format | MEDLINE/PubMed |
spelling | pubmed-51205822016-12-01 The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography Hou, Wei-Hsien Wang, Chun-Wei Tsai, Chiao-Ling Hsu, Feng-Ming Cheng, Jason Chia-Hsien Radiol Oncol Research Article BACKGROUND: Changes in head and neck anatomy during radiation therapy (RT) produce setup uncertainties of nasopharyngeal cancer (NPC) irradiation. We retrospectively analyzed image guidance data to identify clinical predictors of setup errors. PATIENTS AND METHODS: The data of 217 NPC patients undergoing definitive RT on a helical tomotherapy (HT) unit were analyzed. Factors including tumor stage, body mass index, weight loss, and planning target volume (PTV) were assessed as predictors of daily megavoltage computed tomography (MVCT) setup displacements, which were automatically registered using software. RESULTS: Mean daily setup displacements (in mm) were 1.2 ± 0.6, 1.8 ± 0.8, 3.4 ± 1.4 in the medial-lateral (ML), superior-inferior (SI), and anterior-posterior (AP) directions, respectively. Mean weight loss was 4.6 ± 3.3 kg (6.8 ± 4.9%). Patients with weight loss > 5% had significantly larger setup displacements in the AP (3.6 ± 1.5 vs. 2.9 ± 1.1 mm, p < 0.001) and SI (1.6 ± 0.7 vs. 1.9 ± 0.9 mm, p = 0.01) direction, but not in the ML direction (p = 0.279). The AP setup error increased 0.06 mm (y = 0.055x + 2.927, x: percentage of weight loss/PTV, y: AP displacement) per one percent increase in weight loss normalized to PTV. CONCLUSIONS: Patients with weight loss > 5% and smaller PTVs, possibly because of small body frame or neck girth, were more likely to have increased setup errors in the AP direction. De Gruyter 2016-09-08 /pmc/articles/PMC5120582/ /pubmed/27904451 http://dx.doi.org/10.1515/raon-2016-0047 Text en © 2016 Radiol Oncol |
spellingShingle | Research Article Hou, Wei-Hsien Wang, Chun-Wei Tsai, Chiao-Ling Hsu, Feng-Ming Cheng, Jason Chia-Hsien The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography |
title | The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography |
title_full | The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography |
title_fullStr | The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography |
title_full_unstemmed | The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography |
title_short | The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography |
title_sort | ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5120582/ https://www.ncbi.nlm.nih.gov/pubmed/27904451 http://dx.doi.org/10.1515/raon-2016-0047 |
work_keys_str_mv | AT houweihsien theratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT wangchunwei theratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT tsaichiaoling theratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT hsufengming theratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT chengjasonchiahsien theratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT houweihsien ratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT wangchunwei ratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT tsaichiaoling ratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT hsufengming ratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography AT chengjasonchiahsien ratioofweightlosstoplanningtargetvolumesignificantlyimpactssetuperrorsinnasopharyngealcancerpatientsundergoinghelicaltomotherapywithdailymegavoltagecomputedtomography |