Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy

BACKGROUND: Standard applicators for cervical cancer Brachytherapy (BT) do not always achieve acceptable balance between target volume and normal tissue irradiation. We aimed to develop an innovative method of Target-volume Density Mapping (TDM) for modelling of novel applicator prototypes with opti...

Descripción completa

Detalles Bibliográficos
Autores principales: Petric, Primoz, Hudej, Robert, Al-Hammadi, Noora, Segedin, Barbara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: De Gruyter 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5120583/
https://www.ncbi.nlm.nih.gov/pubmed/27904452
http://dx.doi.org/10.1515/raon-2016-0048
_version_ 1782469269842296832
author Petric, Primoz
Hudej, Robert
Al-Hammadi, Noora
Segedin, Barbara
author_facet Petric, Primoz
Hudej, Robert
Al-Hammadi, Noora
Segedin, Barbara
author_sort Petric, Primoz
collection PubMed
description BACKGROUND: Standard applicators for cervical cancer Brachytherapy (BT) do not always achieve acceptable balance between target volume and normal tissue irradiation. We aimed to develop an innovative method of Target-volume Density Mapping (TDM) for modelling of novel applicator prototypes with optimal coverage characteristics. Patients and methods. Development of Contour-Analysis Tool 2 (CAT-2) software for TDM generation was the core priority of our task group. Main requests regarding software functionalities were formulated and guided the coding process. Software validation and accuracy check was performed using phantom objects. Concepts and terms for standardized workflow of TDM post-processing and applicator development were introduced. RESULTS: CAT-2 enables applicator-based co-registration of Digital Imaging and Communications in Medicine (DICOM) structures from a sample of cases, generating a TDM with pooled contours in applicator-eye-view. Each TDM voxel is assigned a value, corresponding to the number of target contours encompassing that voxel. Values are converted to grey levels and transformed to DICOM image, which is transported to the treatment planning system. Iso-density contours (IDC) are generated as lines, connecting voxels with same grey levels. Residual Volume at Risk (RVR) is created for each IDC as potential volume that could contain organs at risk. Finally, standard and prototype applicators are applied on the TDM and virtual dose planning is performed. Dose volume histogram (DVH) parameters are recorded for individual IDC and RVR delineations and characteristic curves generated. Optimal applicator configuration is determined in an iterative manner based on comparison of characteristic curves, virtual implant complexities and isodose distributions. CONCLUSIONS: Using the TDM approach, virtual applicator prototypes capable of conformal coverage of any target volume, can be modelled. Further systematic assessment, including studies on clinical feasibility, safety and effectiveness are needed before routine use of novel prototypes can be considered.
format Online
Article
Text
id pubmed-5120583
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher De Gruyter
record_format MEDLINE/PubMed
spelling pubmed-51205832016-12-01 Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy Petric, Primoz Hudej, Robert Al-Hammadi, Noora Segedin, Barbara Radiol Oncol Research Article BACKGROUND: Standard applicators for cervical cancer Brachytherapy (BT) do not always achieve acceptable balance between target volume and normal tissue irradiation. We aimed to develop an innovative method of Target-volume Density Mapping (TDM) for modelling of novel applicator prototypes with optimal coverage characteristics. Patients and methods. Development of Contour-Analysis Tool 2 (CAT-2) software for TDM generation was the core priority of our task group. Main requests regarding software functionalities were formulated and guided the coding process. Software validation and accuracy check was performed using phantom objects. Concepts and terms for standardized workflow of TDM post-processing and applicator development were introduced. RESULTS: CAT-2 enables applicator-based co-registration of Digital Imaging and Communications in Medicine (DICOM) structures from a sample of cases, generating a TDM with pooled contours in applicator-eye-view. Each TDM voxel is assigned a value, corresponding to the number of target contours encompassing that voxel. Values are converted to grey levels and transformed to DICOM image, which is transported to the treatment planning system. Iso-density contours (IDC) are generated as lines, connecting voxels with same grey levels. Residual Volume at Risk (RVR) is created for each IDC as potential volume that could contain organs at risk. Finally, standard and prototype applicators are applied on the TDM and virtual dose planning is performed. Dose volume histogram (DVH) parameters are recorded for individual IDC and RVR delineations and characteristic curves generated. Optimal applicator configuration is determined in an iterative manner based on comparison of characteristic curves, virtual implant complexities and isodose distributions. CONCLUSIONS: Using the TDM approach, virtual applicator prototypes capable of conformal coverage of any target volume, can be modelled. Further systematic assessment, including studies on clinical feasibility, safety and effectiveness are needed before routine use of novel prototypes can be considered. De Gruyter 2016-11-09 /pmc/articles/PMC5120583/ /pubmed/27904452 http://dx.doi.org/10.1515/raon-2016-0048 Text en © 2016 Radiol Oncol
spellingShingle Research Article
Petric, Primoz
Hudej, Robert
Al-Hammadi, Noora
Segedin, Barbara
Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
title Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
title_full Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
title_fullStr Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
title_full_unstemmed Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
title_short Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
title_sort virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5120583/
https://www.ncbi.nlm.nih.gov/pubmed/27904452
http://dx.doi.org/10.1515/raon-2016-0048
work_keys_str_mv AT petricprimoz virtualmodellingofnovelapplicatorprototypesforcervicalcancerbrachytherapy
AT hudejrobert virtualmodellingofnovelapplicatorprototypesforcervicalcancerbrachytherapy
AT alhammadinoora virtualmodellingofnovelapplicatorprototypesforcervicalcancerbrachytherapy
AT segedinbarbara virtualmodellingofnovelapplicatorprototypesforcervicalcancerbrachytherapy