Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization
To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol. We prospectively enrolled 100 patients with tac...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5120957/ https://www.ncbi.nlm.nih.gov/pubmed/27861400 http://dx.doi.org/10.1097/MD.0000000000005459 |
_version_ | 1782469333084012544 |
---|---|
author | Iyama, Yuji Nakaura, Takeshi Yokoyama, Koichi Kidoh, Masafumi Yamashita, Yasuyuki |
author_facet | Iyama, Yuji Nakaura, Takeshi Yokoyama, Koichi Kidoh, Masafumi Yamashita, Yasuyuki |
author_sort | Iyama, Yuji |
collection | PubMed |
description | To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol. We prospectively enrolled 100 patients with tachycardia or atrial fibrillation scanned retrospective ECG-gated cardiac CT. We randomly assigned 50 patients to the 120-kVp protocol and 50 patients to the 100-kVp protocol. We compared effective doses (EDs) between the two protocols. The 120-kVp images were post-processed using filtered back projection (FBP). The 100-kVp images were post-processed using FBP (100-kVp protocol) and HIR (i-100-kVp protocol). We compared attenuation of the ascending aorta, signal-to-noise ratio (SNR), and image noise between the 120-kVp, 100-kVp, and i-100-kVp protocols. We performed qualitative image analysis for the 120-kVp and i-100-kVp protocols. ED of the 100-kVp protocol (4.4 ± 0.4 mSv) was 76% lower than that of the 120-kVp protocol (18.4 ± 0.6 mSv). Attenuations of the 100-kVp (549.1 ± 73.8 HU) and i-100-kVp (550.5 ± 73.7 HU) protocols were higher than that of the120-kVp protocol (437.3 ± 55.7 HU). Image noise of the 100-kVp (53.6 ± 18.5 HU) and i-100-kVp (30.9 ± 8.6 HU) protocols were higher than that of the120-kVp protocol (23.8 ± 5.7 HU). There was no significant difference in SNR and the result of qualitative image analysis between the 120-kVp and i-100-kVp protocols. The 100-kVp protocol with HIR reduced the 76% radiation dose while preserving the image quality compared with the conventional 120-kVp protocol on retrospective ECG-gated cardiac CT. |
format | Online Article Text |
id | pubmed-5120957 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-51209572016-11-28 Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization Iyama, Yuji Nakaura, Takeshi Yokoyama, Koichi Kidoh, Masafumi Yamashita, Yasuyuki Medicine (Baltimore) 6800 To compare the radiation dose and image quality of retrospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) between a 100-kVp protocol, hybrid iterative reconstruction (HIR), and display preset optimization and the 120-kVp protocol. We prospectively enrolled 100 patients with tachycardia or atrial fibrillation scanned retrospective ECG-gated cardiac CT. We randomly assigned 50 patients to the 120-kVp protocol and 50 patients to the 100-kVp protocol. We compared effective doses (EDs) between the two protocols. The 120-kVp images were post-processed using filtered back projection (FBP). The 100-kVp images were post-processed using FBP (100-kVp protocol) and HIR (i-100-kVp protocol). We compared attenuation of the ascending aorta, signal-to-noise ratio (SNR), and image noise between the 120-kVp, 100-kVp, and i-100-kVp protocols. We performed qualitative image analysis for the 120-kVp and i-100-kVp protocols. ED of the 100-kVp protocol (4.4 ± 0.4 mSv) was 76% lower than that of the 120-kVp protocol (18.4 ± 0.6 mSv). Attenuations of the 100-kVp (549.1 ± 73.8 HU) and i-100-kVp (550.5 ± 73.7 HU) protocols were higher than that of the120-kVp protocol (437.3 ± 55.7 HU). Image noise of the 100-kVp (53.6 ± 18.5 HU) and i-100-kVp (30.9 ± 8.6 HU) protocols were higher than that of the120-kVp protocol (23.8 ± 5.7 HU). There was no significant difference in SNR and the result of qualitative image analysis between the 120-kVp and i-100-kVp protocols. The 100-kVp protocol with HIR reduced the 76% radiation dose while preserving the image quality compared with the conventional 120-kVp protocol on retrospective ECG-gated cardiac CT. Wolters Kluwer Health 2016-11-18 /pmc/articles/PMC5120957/ /pubmed/27861400 http://dx.doi.org/10.1097/MD.0000000000005459 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 |
spellingShingle | 6800 Iyama, Yuji Nakaura, Takeshi Yokoyama, Koichi Kidoh, Masafumi Yamashita, Yasuyuki Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization |
title | Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization |
title_full | Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization |
title_fullStr | Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization |
title_full_unstemmed | Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization |
title_short | Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization |
title_sort | cardiac helical ct involving a low-radiation-dose protocol with a 100-kvp setting: usefulness of hybrid iterative reconstruction and display preset optimization |
topic | 6800 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5120957/ https://www.ncbi.nlm.nih.gov/pubmed/27861400 http://dx.doi.org/10.1097/MD.0000000000005459 |
work_keys_str_mv | AT iyamayuji cardiachelicalctinvolvingalowradiationdoseprotocolwitha100kvpsettingusefulnessofhybriditerativereconstructionanddisplaypresetoptimization AT nakauratakeshi cardiachelicalctinvolvingalowradiationdoseprotocolwitha100kvpsettingusefulnessofhybriditerativereconstructionanddisplaypresetoptimization AT yokoyamakoichi cardiachelicalctinvolvingalowradiationdoseprotocolwitha100kvpsettingusefulnessofhybriditerativereconstructionanddisplaypresetoptimization AT kidohmasafumi cardiachelicalctinvolvingalowradiationdoseprotocolwitha100kvpsettingusefulnessofhybriditerativereconstructionanddisplaypresetoptimization AT yamashitayasuyuki cardiachelicalctinvolvingalowradiationdoseprotocolwitha100kvpsettingusefulnessofhybriditerativereconstructionanddisplaypresetoptimization |