Cargando…

Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study

The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate t...

Descripción completa

Detalles Bibliográficos
Autores principales: Matys, Jacek, Flieger, Rafał, Dominiak, Marzena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5121450/
https://www.ncbi.nlm.nih.gov/pubmed/27957502
http://dx.doi.org/10.1155/2016/9654975
_version_ 1782469407656640512
author Matys, Jacek
Flieger, Rafał
Dominiak, Marzena
author_facet Matys, Jacek
Flieger, Rafał
Dominiak, Marzena
author_sort Matys, Jacek
collection PubMed
description The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate the bone carbonization occurrence. The research included 60 mandibles (n = 60) of adult pigs, divided into 4 groups (n = 15). Two vertical and one horizontal cut have been done in an alveolar ridge using Er:YAG laser with set power of 200 mJ (G1), 400 mJ (G2), piezosurgery unit (G3), and a saw (G4). The temperature was measured by K-type thermocouple. The highest temperature gradient was noted for piezosurgery on the buccal and lingual side of mandible. The temperature rises on the bone surface along with the increase of laser power. The lower time needed to perform ridge splitting was measured for a saw, piezosurgery, and Er:YAG laser with power of 400 mJ and 200 mJ, respectively. The temperature rise measured on the bone over 10°C and bone carbonization occurrence was not reported in all study groups. Piezosurgery, Er:YAG laser (200 mJ and 400 mJ), and surgical saw are useful and safe tools in ridge splitting surgery.
format Online
Article
Text
id pubmed-5121450
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-51214502016-12-12 Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study Matys, Jacek Flieger, Rafał Dominiak, Marzena Biomed Res Int Research Article The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate the bone carbonization occurrence. The research included 60 mandibles (n = 60) of adult pigs, divided into 4 groups (n = 15). Two vertical and one horizontal cut have been done in an alveolar ridge using Er:YAG laser with set power of 200 mJ (G1), 400 mJ (G2), piezosurgery unit (G3), and a saw (G4). The temperature was measured by K-type thermocouple. The highest temperature gradient was noted for piezosurgery on the buccal and lingual side of mandible. The temperature rises on the bone surface along with the increase of laser power. The lower time needed to perform ridge splitting was measured for a saw, piezosurgery, and Er:YAG laser with power of 400 mJ and 200 mJ, respectively. The temperature rise measured on the bone over 10°C and bone carbonization occurrence was not reported in all study groups. Piezosurgery, Er:YAG laser (200 mJ and 400 mJ), and surgical saw are useful and safe tools in ridge splitting surgery. Hindawi Publishing Corporation 2016 2016-11-10 /pmc/articles/PMC5121450/ /pubmed/27957502 http://dx.doi.org/10.1155/2016/9654975 Text en Copyright © 2016 Jacek Matys et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Matys, Jacek
Flieger, Rafał
Dominiak, Marzena
Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study
title Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study
title_full Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study
title_fullStr Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study
title_full_unstemmed Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study
title_short Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study
title_sort assessment of temperature rise and time of alveolar ridge splitting by means of er:yag laser, piezosurgery, and surgical saw: an ex vivo study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5121450/
https://www.ncbi.nlm.nih.gov/pubmed/27957502
http://dx.doi.org/10.1155/2016/9654975
work_keys_str_mv AT matysjacek assessmentoftemperatureriseandtimeofalveolarridgesplittingbymeansoferyaglaserpiezosurgeryandsurgicalsawanexvivostudy
AT fliegerrafał assessmentoftemperatureriseandtimeofalveolarridgesplittingbymeansoferyaglaserpiezosurgeryandsurgicalsawanexvivostudy
AT dominiakmarzena assessmentoftemperatureriseandtimeofalveolarridgesplittingbymeansoferyaglaserpiezosurgeryandsurgicalsawanexvivostudy