BACKGROUND: The purpose of this study is to find the optimal planning settings for prostate SABR-VMAT for high-risk prostate cancer patients irradiated to prostate only (PO) or prostate and pelvic lymph nodes (PPLN). METHODS: For 10 patients, plans using 6MV flattened, flattening-filter-free (FFF) 6...

Descripción completa

Detalles Bibliográficos
Autores principales: Osman, Sarah O. S., Jeevanandam, Prakash, Kanakavelu, Nithya, Irvine, Denise M., Lyons, Ciara A., Jain, Suneil, Hounsell, Alan R., McGarry, Conor K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5121961/
https://www.ncbi.nlm.nih.gov/pubmed/27881187
http://dx.doi.org/10.1186/s13014-016-0730-7
_version_ 1782469478914719744
author Osman, Sarah O. S.
Jeevanandam, Prakash
Kanakavelu, Nithya
Irvine, Denise M.
Lyons, Ciara A.
Jain, Suneil
Hounsell, Alan R.
McGarry, Conor K.
author_facet Osman, Sarah O. S.
Jeevanandam, Prakash
Kanakavelu, Nithya
Irvine, Denise M.
Lyons, Ciara A.
Jain, Suneil
Hounsell, Alan R.
McGarry, Conor K.
author_sort Osman, Sarah O. S.
collection PubMed
description BACKGROUND: The purpose of this study is to find the optimal planning settings for prostate SABR-VMAT for high-risk prostate cancer patients irradiated to prostate only (PO) or prostate and pelvic lymph nodes (PPLN). METHODS: For 10 patients, plans using 6MV flattened, flattening-filter-free (FFF) 6MV (6 F) and FFF 10MV (10 F) photon beams with full and partial arc arrangements were generated and compared. The prescribed dose was 40Gy to the prostate with 25Gy to the PLN in 5 fractions. Plans were then evaluated for PTV coverage, dose fall-off, and OAR doses. The number of monitor units and the treatment delivery times were also compared. Statistical differences were evaluated using a paired sample Wilcoxon signed rank test with a significance level of 0.05%. RESULTS: A total of 150 plans were generated for this study. Acceptable PO plans were obtained using single arcs, while two arcs were necessary for PPLN. All plans were highly conformal (CI ≥1.3 and CN ≥0.90) with no significant differences in the PTV dose coverage. 6MV plans required significantly longer treatment time and had higher dose spillage compared to FFF plans. Superior plans were obtained using 10 F 300° partial arcs for PO with the lowest rectal dose, dose spillage and the shortest treatment times. For PPLN, 6 F and 10 F plans were equivalent. CONCLUSIONS: SABR-VMAT with FFF photon beams offers a clear benefit with respect to shorter treatment delivery times and reduced dose spillage. Class solutions using a single 10 F 300° arc for PO and two 10 F or 6 F partial 300° arcs for PPLN are proposed. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-016-0730-7) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5121961
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-51219612016-11-30 Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation Osman, Sarah O. S. Jeevanandam, Prakash Kanakavelu, Nithya Irvine, Denise M. Lyons, Ciara A. Jain, Suneil Hounsell, Alan R. McGarry, Conor K. Radiat Oncol Research BACKGROUND: The purpose of this study is to find the optimal planning settings for prostate SABR-VMAT for high-risk prostate cancer patients irradiated to prostate only (PO) or prostate and pelvic lymph nodes (PPLN). METHODS: For 10 patients, plans using 6MV flattened, flattening-filter-free (FFF) 6MV (6 F) and FFF 10MV (10 F) photon beams with full and partial arc arrangements were generated and compared. The prescribed dose was 40Gy to the prostate with 25Gy to the PLN in 5 fractions. Plans were then evaluated for PTV coverage, dose fall-off, and OAR doses. The number of monitor units and the treatment delivery times were also compared. Statistical differences were evaluated using a paired sample Wilcoxon signed rank test with a significance level of 0.05%. RESULTS: A total of 150 plans were generated for this study. Acceptable PO plans were obtained using single arcs, while two arcs were necessary for PPLN. All plans were highly conformal (CI ≥1.3 and CN ≥0.90) with no significant differences in the PTV dose coverage. 6MV plans required significantly longer treatment time and had higher dose spillage compared to FFF plans. Superior plans were obtained using 10 F 300° partial arcs for PO with the lowest rectal dose, dose spillage and the shortest treatment times. For PPLN, 6 F and 10 F plans were equivalent. CONCLUSIONS: SABR-VMAT with FFF photon beams offers a clear benefit with respect to shorter treatment delivery times and reduced dose spillage. Class solutions using a single 10 F 300° arc for PO and two 10 F or 6 F partial 300° arcs for PPLN are proposed. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-016-0730-7) contains supplementary material, which is available to authorized users. BioMed Central 2016-11-24 /pmc/articles/PMC5121961/ /pubmed/27881187 http://dx.doi.org/10.1186/s13014-016-0730-7 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Osman, Sarah O. S.
Jeevanandam, Prakash
Kanakavelu, Nithya
Irvine, Denise M.
Lyons, Ciara A.
Jain, Suneil
Hounsell, Alan R.
McGarry, Conor K.
Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation
title Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation
title_full Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation
title_fullStr Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation
title_full_unstemmed Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation
title_short Class solutions for SABR-VMAT for high-risk prostate cancer with and without elective nodal irradiation
title_sort class solutions for sabr-vmat for high-risk prostate cancer with and without elective nodal irradiation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5121961/
https://www.ncbi.nlm.nih.gov/pubmed/27881187
http://dx.doi.org/10.1186/s13014-016-0730-7
work_keys_str_mv AT osmansarahos classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation
AT jeevanandamprakash classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation
AT kanakavelunithya classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation
AT irvinedenisem classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation
AT lyonsciaraa classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation
AT jainsuneil classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation
AT hounsellalanr classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation
AT mcgarryconork classsolutionsforsabrvmatforhighriskprostatecancerwithandwithoutelectivenodalirradiation