Cargando…

Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study

BACKGROUND: Fluid in the subcutaneous fat is a common finding anterior to the knee on MRI. This may be caused by chronic low-grade shearing injuries in patients who are overweight. The purpose of this study was to determine if there is a difference in the amount of subcutaneous fat around the knee b...

Descripción completa

Detalles Bibliográficos
Autores principales: Trevor, Gaunt, Carey, Frank, Cahir, John, Toms, Andoni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5121968/
https://www.ncbi.nlm.nih.gov/pubmed/27881111
http://dx.doi.org/10.1186/s12891-016-1345-8
_version_ 1782469480579858432
author Trevor, Gaunt
Carey, Frank
Cahir, John
Toms, Andoni
author_facet Trevor, Gaunt
Carey, Frank
Cahir, John
Toms, Andoni
author_sort Trevor, Gaunt
collection PubMed
description BACKGROUND: Fluid in the subcutaneous fat is a common finding anterior to the knee on MRI. This may be caused by chronic low-grade shearing injuries in patients who are overweight. The purpose of this study was to determine if there is a difference in the amount of subcutaneous fat around the knee between patients with these appearances and controls. METHODS: This was a retrospective case-control study. Following a sample size calculation on pilot data, eighteen sequential patients demonstrating hyper-intense subcutaneous signal changes around the knee on fat-saturated T2-weighted MRI were identified from PACS (18 females, mean age 45, range 31–62). Age and gender-matched patients without abnormal T2 MR signal changes were selected. Two observers independently drew regions of interest representing cross-sectional areas of bone and fat. The location of T2 signal hyper-intense lesions was characterized by consensus. RESULTS: Inter and intra-rater intraclass reproducibility was “excellent” (ICC > 0.8). The mean cross-sectional area of bone for patients with T2 hyper-intense lesions was 31.79cm(2) (SD 2.57) and for controls 30.11cm(2) (SD 3.20) which was not significantly different (p = 0.09). The median cross-sectional area of fat for the study group was 62.29cm(2) (IQR 57.1–66.5) and for controls was 32.77cm(2) (IQR 24.8–32.3) which was significantly different (p < 0.0001). Consensus agreement demonstrated all T2 hyper-intense lesions were anterior to the knee extensor mechanism. CONCLUSION: Subcutaneous fluid around the knee is associated with an increased amount of subcutaneous fat, anterior to the knee extensor mechanism. This may be caused by shearing injuries in fat with reduced elasticity associated with metabolic syndrome.
format Online
Article
Text
id pubmed-5121968
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-51219682016-11-30 Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study Trevor, Gaunt Carey, Frank Cahir, John Toms, Andoni BMC Musculoskelet Disord Research Article BACKGROUND: Fluid in the subcutaneous fat is a common finding anterior to the knee on MRI. This may be caused by chronic low-grade shearing injuries in patients who are overweight. The purpose of this study was to determine if there is a difference in the amount of subcutaneous fat around the knee between patients with these appearances and controls. METHODS: This was a retrospective case-control study. Following a sample size calculation on pilot data, eighteen sequential patients demonstrating hyper-intense subcutaneous signal changes around the knee on fat-saturated T2-weighted MRI were identified from PACS (18 females, mean age 45, range 31–62). Age and gender-matched patients without abnormal T2 MR signal changes were selected. Two observers independently drew regions of interest representing cross-sectional areas of bone and fat. The location of T2 signal hyper-intense lesions was characterized by consensus. RESULTS: Inter and intra-rater intraclass reproducibility was “excellent” (ICC > 0.8). The mean cross-sectional area of bone for patients with T2 hyper-intense lesions was 31.79cm(2) (SD 2.57) and for controls 30.11cm(2) (SD 3.20) which was not significantly different (p = 0.09). The median cross-sectional area of fat for the study group was 62.29cm(2) (IQR 57.1–66.5) and for controls was 32.77cm(2) (IQR 24.8–32.3) which was significantly different (p < 0.0001). Consensus agreement demonstrated all T2 hyper-intense lesions were anterior to the knee extensor mechanism. CONCLUSION: Subcutaneous fluid around the knee is associated with an increased amount of subcutaneous fat, anterior to the knee extensor mechanism. This may be caused by shearing injuries in fat with reduced elasticity associated with metabolic syndrome. BioMed Central 2016-11-24 /pmc/articles/PMC5121968/ /pubmed/27881111 http://dx.doi.org/10.1186/s12891-016-1345-8 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Trevor, Gaunt
Carey, Frank
Cahir, John
Toms, Andoni
Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study
title Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study
title_full Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study
title_fullStr Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study
title_full_unstemmed Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study
title_short Fluid signal changes around the knee on MRI are associated with increased volumes of subcutaneous fat: a case-control study
title_sort fluid signal changes around the knee on mri are associated with increased volumes of subcutaneous fat: a case-control study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5121968/
https://www.ncbi.nlm.nih.gov/pubmed/27881111
http://dx.doi.org/10.1186/s12891-016-1345-8
work_keys_str_mv AT trevorgaunt fluidsignalchangesaroundthekneeonmriareassociatedwithincreasedvolumesofsubcutaneousfatacasecontrolstudy
AT careyfrank fluidsignalchangesaroundthekneeonmriareassociatedwithincreasedvolumesofsubcutaneousfatacasecontrolstudy
AT cahirjohn fluidsignalchangesaroundthekneeonmriareassociatedwithincreasedvolumesofsubcutaneousfatacasecontrolstudy
AT tomsandoni fluidsignalchangesaroundthekneeonmriareassociatedwithincreasedvolumesofsubcutaneousfatacasecontrolstudy