Cargando…
Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI
BACKGROUND: Accurate synchronization between magnetic resonance imaging data acquisition and a subject’s cardiac activity (“triggering”) is essential for reducing image artifacts but conventional, contact-based methods for this task are limited by several factors, including preparation time, patient...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5122166/ https://www.ncbi.nlm.nih.gov/pubmed/27881126 http://dx.doi.org/10.1186/s12938-016-0245-3 |
_version_ | 1782469521738563584 |
---|---|
author | Spicher, Nicolai Kukuk, Markus Maderwald, Stefan Ladd, Mark E. |
author_facet | Spicher, Nicolai Kukuk, Markus Maderwald, Stefan Ladd, Mark E. |
author_sort | Spicher, Nicolai |
collection | PubMed |
description | BACKGROUND: Accurate synchronization between magnetic resonance imaging data acquisition and a subject’s cardiac activity (“triggering”) is essential for reducing image artifacts but conventional, contact-based methods for this task are limited by several factors, including preparation time, patient inconvenience, and susceptibility to signal degradation. The purpose of this work is to evaluate the performance of a new contact-free triggering method developed with the aim to eventually replace conventional methods in non-cardiac imaging applications. In this study, the method’s performance is evaluated in the context of 7 Tesla non-enhanced angiography of the lower extremities. METHODS: Our main contribution is a basic algorithm capable of estimating in real-time the phase of the cardiac cycle from reflection photoplethysmography signals obtained from skin color variations of the forehead recorded with a video camera. Instead of finding the algorithm’s parameters heuristically, they were optimized using videos of the forehead as well as electrocardiography and pulse oximetry signals that were recorded from eight healthy volunteers in and outside the scanner, with and without active radio frequency and gradient coils. Based on the video characteristics, synthetic signals were generated and the “best available” values of an objective function were determined using mathematical optimization. The performance of the proposed method with optimized algorithm parameters was evaluated by applying it to the recorded videos and comparing the computed triggers to those of contact-based methods. Additionally, the method was evaluated by using its triggers for acquiring images from a healthy volunteer and comparing the result to images obtained using pulse oximetry triggering. RESULTS: During evaluation of the videos recorded inside the bore with active radio frequency and gradient coils, the pulse oximeter triggers were labeled in 62.5% as “potentially usable” for cardiac triggering, the electrocardiography triggers in 12.5%, and the proposed method’s triggers in 62.5%. Evaluation of the angiography images demonstrated that under appropriate conditions the method is feasible to produce an image quality comparable to pulse oximetry. CONCLUSION: We conclude that cardiac triggering using the proposed method is technically feasible. However, for improved reliability the signal-to-noise ratio of the videos will have to be addressed by either replacing the camera sensor, improving the illumination, or by use of additional signal filtering techniques. |
format | Online Article Text |
id | pubmed-5122166 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-51221662016-11-30 Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI Spicher, Nicolai Kukuk, Markus Maderwald, Stefan Ladd, Mark E. Biomed Eng Online Research BACKGROUND: Accurate synchronization between magnetic resonance imaging data acquisition and a subject’s cardiac activity (“triggering”) is essential for reducing image artifacts but conventional, contact-based methods for this task are limited by several factors, including preparation time, patient inconvenience, and susceptibility to signal degradation. The purpose of this work is to evaluate the performance of a new contact-free triggering method developed with the aim to eventually replace conventional methods in non-cardiac imaging applications. In this study, the method’s performance is evaluated in the context of 7 Tesla non-enhanced angiography of the lower extremities. METHODS: Our main contribution is a basic algorithm capable of estimating in real-time the phase of the cardiac cycle from reflection photoplethysmography signals obtained from skin color variations of the forehead recorded with a video camera. Instead of finding the algorithm’s parameters heuristically, they were optimized using videos of the forehead as well as electrocardiography and pulse oximetry signals that were recorded from eight healthy volunteers in and outside the scanner, with and without active radio frequency and gradient coils. Based on the video characteristics, synthetic signals were generated and the “best available” values of an objective function were determined using mathematical optimization. The performance of the proposed method with optimized algorithm parameters was evaluated by applying it to the recorded videos and comparing the computed triggers to those of contact-based methods. Additionally, the method was evaluated by using its triggers for acquiring images from a healthy volunteer and comparing the result to images obtained using pulse oximetry triggering. RESULTS: During evaluation of the videos recorded inside the bore with active radio frequency and gradient coils, the pulse oximeter triggers were labeled in 62.5% as “potentially usable” for cardiac triggering, the electrocardiography triggers in 12.5%, and the proposed method’s triggers in 62.5%. Evaluation of the angiography images demonstrated that under appropriate conditions the method is feasible to produce an image quality comparable to pulse oximetry. CONCLUSION: We conclude that cardiac triggering using the proposed method is technically feasible. However, for improved reliability the signal-to-noise ratio of the videos will have to be addressed by either replacing the camera sensor, improving the illumination, or by use of additional signal filtering techniques. BioMed Central 2016-11-24 /pmc/articles/PMC5122166/ /pubmed/27881126 http://dx.doi.org/10.1186/s12938-016-0245-3 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Spicher, Nicolai Kukuk, Markus Maderwald, Stefan Ladd, Mark E. Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI |
title | Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI |
title_full | Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI |
title_fullStr | Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI |
title_full_unstemmed | Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI |
title_short | Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI |
title_sort | initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7t mri |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5122166/ https://www.ncbi.nlm.nih.gov/pubmed/27881126 http://dx.doi.org/10.1186/s12938-016-0245-3 |
work_keys_str_mv | AT spichernicolai initialevaluationofprospectivecardiactriggeringusingphotoplethysmographysignalsrecordedwithavideocameracomparedtopulseoximetryandelectrocardiographyat7tmri AT kukukmarkus initialevaluationofprospectivecardiactriggeringusingphotoplethysmographysignalsrecordedwithavideocameracomparedtopulseoximetryandelectrocardiographyat7tmri AT maderwaldstefan initialevaluationofprospectivecardiactriggeringusingphotoplethysmographysignalsrecordedwithavideocameracomparedtopulseoximetryandelectrocardiographyat7tmri AT laddmarke initialevaluationofprospectivecardiactriggeringusingphotoplethysmographysignalsrecordedwithavideocameracomparedtopulseoximetryandelectrocardiographyat7tmri |