Cargando…
What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner
BACKGROUND: Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limit...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5122261/ https://www.ncbi.nlm.nih.gov/pubmed/27904221 http://dx.doi.org/10.4103/0019-5413.193488 |
_version_ | 1782469543026753536 |
---|---|
author | Vaidya, Shrinand V Virani, Siddharth Phunde, Rajendra Mahajan, Abhishek |
author_facet | Vaidya, Shrinand V Virani, Siddharth Phunde, Rajendra Mahajan, Abhishek |
author_sort | Vaidya, Shrinand V |
collection | PubMed |
description | BACKGROUND: Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limited data. This is the first study by a non-designer on the press fit condylar rotating platform posterior stabilized (PFC-RP-PS) design with 100’ success. This has a relevance, vis-á -vis bias that one may have in terms of reproducibility of technique and funding from the manufacturer. We associate our excellent mid-term results to intra operative technical aspects and stringent intra operative exclusion criteria. MATERIALS AND METHODS: Our study includes a cohort of 121 selected knees operated between January 2003 and October 2010. We used cemented, posterior stabilized (PS), mobile bearing (MB), and RP prosthesis from the same manufacturer in all these 121 knees. The patients were evaluated bi-annually with the calculation of their Knee Society Scores (KSS) and a radiological assessment for loosening/osteolysis. RESULTS: 120 knees were available for followup. The average Knee Society clinical and functional scores, respectively, were 27 points and 40 points preoperatively and 93 points and 95 points postoperatively. This indicates a mean increase of about 71’ in the clinical score and about 58’ in the functional score, which is statistically significant. The mean postoperative flexion was 124°, a mean increase of 23° from the preoperative flexion of 101°. There were no revisions (Kaplan-–Meier survivorship of 100’). CONCLUSIONS: We feel durable and reproducible results of PFC-RP-PS design knees are very technique sensitive. The way ahead with the PFC-RP-PS knees looks promising when the exclusion criteria for this design are strictly met. Coming from a non-designer, this study acquires a higher degree of relevance without any designer's or manufacturer's bias. |
format | Online Article Text |
id | pubmed-5122261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-51222612016-11-30 What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner Vaidya, Shrinand V Virani, Siddharth Phunde, Rajendra Mahajan, Abhishek Indian J Orthop Original Article BACKGROUND: Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limited data. This is the first study by a non-designer on the press fit condylar rotating platform posterior stabilized (PFC-RP-PS) design with 100’ success. This has a relevance, vis-á -vis bias that one may have in terms of reproducibility of technique and funding from the manufacturer. We associate our excellent mid-term results to intra operative technical aspects and stringent intra operative exclusion criteria. MATERIALS AND METHODS: Our study includes a cohort of 121 selected knees operated between January 2003 and October 2010. We used cemented, posterior stabilized (PS), mobile bearing (MB), and RP prosthesis from the same manufacturer in all these 121 knees. The patients were evaluated bi-annually with the calculation of their Knee Society Scores (KSS) and a radiological assessment for loosening/osteolysis. RESULTS: 120 knees were available for followup. The average Knee Society clinical and functional scores, respectively, were 27 points and 40 points preoperatively and 93 points and 95 points postoperatively. This indicates a mean increase of about 71’ in the clinical score and about 58’ in the functional score, which is statistically significant. The mean postoperative flexion was 124°, a mean increase of 23° from the preoperative flexion of 101°. There were no revisions (Kaplan-–Meier survivorship of 100’). CONCLUSIONS: We feel durable and reproducible results of PFC-RP-PS design knees are very technique sensitive. The way ahead with the PFC-RP-PS knees looks promising when the exclusion criteria for this design are strictly met. Coming from a non-designer, this study acquires a higher degree of relevance without any designer's or manufacturer's bias. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5122261/ /pubmed/27904221 http://dx.doi.org/10.4103/0019-5413.193488 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Vaidya, Shrinand V Virani, Siddharth Phunde, Rajendra Mahajan, Abhishek What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner |
title | What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner |
title_full | What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner |
title_fullStr | What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner |
title_full_unstemmed | What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner |
title_short | What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner |
title_sort | what have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: a 5-10 years followup by a nondesigner |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5122261/ https://www.ncbi.nlm.nih.gov/pubmed/27904221 http://dx.doi.org/10.4103/0019-5413.193488 |
work_keys_str_mv | AT vaidyashrinandv whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner AT viranisiddharth whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner AT phunderajendra whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner AT mahajanabhishek whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner |