Cargando…

What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner

BACKGROUND: Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limit...

Descripción completa

Detalles Bibliográficos
Autores principales: Vaidya, Shrinand V, Virani, Siddharth, Phunde, Rajendra, Mahajan, Abhishek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5122261/
https://www.ncbi.nlm.nih.gov/pubmed/27904221
http://dx.doi.org/10.4103/0019-5413.193488
_version_ 1782469543026753536
author Vaidya, Shrinand V
Virani, Siddharth
Phunde, Rajendra
Mahajan, Abhishek
author_facet Vaidya, Shrinand V
Virani, Siddharth
Phunde, Rajendra
Mahajan, Abhishek
author_sort Vaidya, Shrinand V
collection PubMed
description BACKGROUND: Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limited data. This is the first study by a non-designer on the press fit condylar rotating platform posterior stabilized (PFC-RP-PS) design with 100’ success. This has a relevance, vis-á -vis bias that one may have in terms of reproducibility of technique and funding from the manufacturer. We associate our excellent mid-term results to intra operative technical aspects and stringent intra operative exclusion criteria. MATERIALS AND METHODS: Our study includes a cohort of 121 selected knees operated between January 2003 and October 2010. We used cemented, posterior stabilized (PS), mobile bearing (MB), and RP prosthesis from the same manufacturer in all these 121 knees. The patients were evaluated bi-annually with the calculation of their Knee Society Scores (KSS) and a radiological assessment for loosening/osteolysis. RESULTS: 120 knees were available for followup. The average Knee Society clinical and functional scores, respectively, were 27 points and 40 points preoperatively and 93 points and 95 points postoperatively. This indicates a mean increase of about 71’ in the clinical score and about 58’ in the functional score, which is statistically significant. The mean postoperative flexion was 124°, a mean increase of 23° from the preoperative flexion of 101°. There were no revisions (Kaplan-–Meier survivorship of 100’). CONCLUSIONS: We feel durable and reproducible results of PFC-RP-PS design knees are very technique sensitive. The way ahead with the PFC-RP-PS knees looks promising when the exclusion criteria for this design are strictly met. Coming from a non-designer, this study acquires a higher degree of relevance without any designer's or manufacturer's bias.
format Online
Article
Text
id pubmed-5122261
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-51222612016-11-30 What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner Vaidya, Shrinand V Virani, Siddharth Phunde, Rajendra Mahajan, Abhishek Indian J Orthop Original Article BACKGROUND: Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limited data. This is the first study by a non-designer on the press fit condylar rotating platform posterior stabilized (PFC-RP-PS) design with 100’ success. This has a relevance, vis-á -vis bias that one may have in terms of reproducibility of technique and funding from the manufacturer. We associate our excellent mid-term results to intra operative technical aspects and stringent intra operative exclusion criteria. MATERIALS AND METHODS: Our study includes a cohort of 121 selected knees operated between January 2003 and October 2010. We used cemented, posterior stabilized (PS), mobile bearing (MB), and RP prosthesis from the same manufacturer in all these 121 knees. The patients were evaluated bi-annually with the calculation of their Knee Society Scores (KSS) and a radiological assessment for loosening/osteolysis. RESULTS: 120 knees were available for followup. The average Knee Society clinical and functional scores, respectively, were 27 points and 40 points preoperatively and 93 points and 95 points postoperatively. This indicates a mean increase of about 71’ in the clinical score and about 58’ in the functional score, which is statistically significant. The mean postoperative flexion was 124°, a mean increase of 23° from the preoperative flexion of 101°. There were no revisions (Kaplan-–Meier survivorship of 100’). CONCLUSIONS: We feel durable and reproducible results of PFC-RP-PS design knees are very technique sensitive. The way ahead with the PFC-RP-PS knees looks promising when the exclusion criteria for this design are strictly met. Coming from a non-designer, this study acquires a higher degree of relevance without any designer's or manufacturer's bias. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5122261/ /pubmed/27904221 http://dx.doi.org/10.4103/0019-5413.193488 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Vaidya, Shrinand V
Virani, Siddharth
Phunde, Rajendra
Mahajan, Abhishek
What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner
title What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner
title_full What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner
title_fullStr What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner
title_full_unstemmed What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner
title_short What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner
title_sort what have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: a 5-10 years followup by a nondesigner
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5122261/
https://www.ncbi.nlm.nih.gov/pubmed/27904221
http://dx.doi.org/10.4103/0019-5413.193488
work_keys_str_mv AT vaidyashrinandv whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner
AT viranisiddharth whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner
AT phunderajendra whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner
AT mahajanabhishek whathavewelearnedfrom100successofpressfitcondylarrotatingplatformposteriorstabilizedkneesa510yearsfollowupbyanondesigner