Cargando…
A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin
The objective of this randomized controlled manikin trial was to examine tidal volume (V(T)) delivery and ventilation rate during mask positive pressure ventilation (PPV) with five different devices, including a volume-controlled prototype Next Step™ device for neonatal resuscitation. We hypothesize...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5124572/ https://www.ncbi.nlm.nih.gov/pubmed/27965949 http://dx.doi.org/10.3389/fped.2016.00129 |
_version_ | 1782469867966824448 |
---|---|
author | Solevåg, Anne Lee Haemmerle, Enrico van Os, Sylvia Bach, Katinka P. Cheung, Po-Yin Schmölzer, Georg M. |
author_facet | Solevåg, Anne Lee Haemmerle, Enrico van Os, Sylvia Bach, Katinka P. Cheung, Po-Yin Schmölzer, Georg M. |
author_sort | Solevåg, Anne Lee |
collection | PubMed |
description | The objective of this randomized controlled manikin trial was to examine tidal volume (V(T)) delivery and ventilation rate during mask positive pressure ventilation (PPV) with five different devices, including a volume-controlled prototype Next Step™ device for neonatal resuscitation. We hypothesized that V(T) and rate would be closest to target with the Next Step™. Twenty-five Neonatal Resuscitation Program providers provided mask PPV to a newborn manikin (simulated weight 1 kg) in a randomized order with a self-inflating bag (SIB), a disposable T-piece, a non-disposable T-piece, a stand-alone resuscitation system T-piece, and the Next Step™. All T-pieces used a peak inflation pressure of 20 cmH(2)O and a positive end-expiratory pressure of 5 cmH(2)O. The participants were instructed to deliver a 5 mL/kg V(T) (rate 40–60/min) for 1 min with each device and each of three test lungs with increasing compliance of 0.5, 1.0, and 2.0 mL/cmH(2)O. V(T) and ventilation rate were compared between devices and compliance levels (linear mixed model). All devices, except the Next Step™ delivered a too high V(T), up to sixfold the target at the 2.0-mL/cmH(2)O compliance. The Next Step™ V(T) was 26% lower than the target in the low compliance. The ventilation rate was within target with the Next Step™ and SIB, and slightly lower with the T-pieces. In conclusion, routinely used newborn resuscitators over delivered V(T), whereas the Next Step™ under delivered in the low compliant test lung. The SIB had higher V(T) and rate than the T-pieces. More research is needed on volume-controlled delivery room ventilation. |
format | Online Article Text |
id | pubmed-5124572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-51245722016-12-13 A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin Solevåg, Anne Lee Haemmerle, Enrico van Os, Sylvia Bach, Katinka P. Cheung, Po-Yin Schmölzer, Georg M. Front Pediatr Pediatrics The objective of this randomized controlled manikin trial was to examine tidal volume (V(T)) delivery and ventilation rate during mask positive pressure ventilation (PPV) with five different devices, including a volume-controlled prototype Next Step™ device for neonatal resuscitation. We hypothesized that V(T) and rate would be closest to target with the Next Step™. Twenty-five Neonatal Resuscitation Program providers provided mask PPV to a newborn manikin (simulated weight 1 kg) in a randomized order with a self-inflating bag (SIB), a disposable T-piece, a non-disposable T-piece, a stand-alone resuscitation system T-piece, and the Next Step™. All T-pieces used a peak inflation pressure of 20 cmH(2)O and a positive end-expiratory pressure of 5 cmH(2)O. The participants were instructed to deliver a 5 mL/kg V(T) (rate 40–60/min) for 1 min with each device and each of three test lungs with increasing compliance of 0.5, 1.0, and 2.0 mL/cmH(2)O. V(T) and ventilation rate were compared between devices and compliance levels (linear mixed model). All devices, except the Next Step™ delivered a too high V(T), up to sixfold the target at the 2.0-mL/cmH(2)O compliance. The Next Step™ V(T) was 26% lower than the target in the low compliance. The ventilation rate was within target with the Next Step™ and SIB, and slightly lower with the T-pieces. In conclusion, routinely used newborn resuscitators over delivered V(T), whereas the Next Step™ under delivered in the low compliant test lung. The SIB had higher V(T) and rate than the T-pieces. More research is needed on volume-controlled delivery room ventilation. Frontiers Media S.A. 2016-11-28 /pmc/articles/PMC5124572/ /pubmed/27965949 http://dx.doi.org/10.3389/fped.2016.00129 Text en Copyright © 2016 Solevåg, Haemmerle, van Os, Bach, Cheung and Schmölzer. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Pediatrics Solevåg, Anne Lee Haemmerle, Enrico van Os, Sylvia Bach, Katinka P. Cheung, Po-Yin Schmölzer, Georg M. A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin |
title | A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin |
title_full | A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin |
title_fullStr | A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin |
title_full_unstemmed | A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin |
title_short | A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin |
title_sort | novel prototype neonatal resuscitator that controls tidal volume and ventilation rate: a comparative study of mask ventilation in a newborn manikin |
topic | Pediatrics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5124572/ https://www.ncbi.nlm.nih.gov/pubmed/27965949 http://dx.doi.org/10.3389/fped.2016.00129 |
work_keys_str_mv | AT solevagannelee anovelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT haemmerleenrico anovelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT vanossylvia anovelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT bachkatinkap anovelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT cheungpoyin anovelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT schmolzergeorgm anovelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT solevagannelee novelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT haemmerleenrico novelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT vanossylvia novelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT bachkatinkap novelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT cheungpoyin novelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin AT schmolzergeorgm novelprototypeneonatalresuscitatorthatcontrolstidalvolumeandventilationrateacomparativestudyofmaskventilationinanewbornmanikin |