Cargando…

Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection

OBJECTIVE: The hybrid gamma camera (HGC) has been developed to enhance the localization of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. To assess the capability of the HGC, a lymph node contrast (LNC) phantom was constructed to s...

Descripción completa

Detalles Bibliográficos
Autores principales: Alqahtani, Mohammed S, Lees, John E, Bugby, Sarah L, Jambi, Layal K, Perkins, Alan C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Institute of Radiology. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5124810/
https://www.ncbi.nlm.nih.gov/pubmed/27537079
http://dx.doi.org/10.1259/bjr.20160435
_version_ 1782469897713876992
author Alqahtani, Mohammed S
Lees, John E
Bugby, Sarah L
Jambi, Layal K
Perkins, Alan C
author_facet Alqahtani, Mohammed S
Lees, John E
Bugby, Sarah L
Jambi, Layal K
Perkins, Alan C
author_sort Alqahtani, Mohammed S
collection PubMed
description OBJECTIVE: The hybrid gamma camera (HGC) has been developed to enhance the localization of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. To assess the capability of the HGC, a lymph node contrast (LNC) phantom was constructed to simulate medical scenarios of varying radioactivity concentrations and SLN size. METHODS: The phantom was constructed using two clear acrylic glass plates. The SLNs were simulated by circular wells of diameters ranging from 10 to 2.5 mm (16 wells in total) in 1 plate. The second plate contains four larger rectangular wells to simulate tissue background activity surrounding the SLNs. The activity used to simulate each SLN ranged between 4 and 0.025 MBq. The activity concentration ratio between the background and the activity injected in the SLNs was 1 : 10. The LNC phantom was placed at different depths of scattering material ranging between 5 and 40 mm. The collimator-to-source distance was 120 mm. Image acquisition times ranged from 60 to 240 s. RESULTS: Contrast-to-noise ratio analysis and full-width-at-half-maximum (FWHM) measurements of the simulated SLNs were carried out for the images obtained. Over the range of activities used, the HGC detected between 87.5 and 100% of the SLNs through 20 mm of scattering material and 75–93.75% of the SLNs through 40 mm of scattering material. The FWHM of the detected SLNs ranged between 11.93 and 14.70 mm. CONCLUSION: The HGC is capable of detecting low accumulation of activity in small SLNs, indicating its usefulness as an intraoperative imaging system during surgical SLN procedures. ADVANCES IN KNOWLEDGE: This study investigates the capability of a novel small-field-of-view (SFOV) HGC to detect low activity uptake in small SLNs. The phantom and procedure described are inexpensive and could be easily replicated and applied to any SFOV camera, to provide a comparison between systems with clinically relevant results.
format Online
Article
Text
id pubmed-5124810
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The British Institute of Radiology.
record_format MEDLINE/PubMed
spelling pubmed-51248102016-12-15 Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection Alqahtani, Mohammed S Lees, John E Bugby, Sarah L Jambi, Layal K Perkins, Alan C Br J Radiol Full Paper OBJECTIVE: The hybrid gamma camera (HGC) has been developed to enhance the localization of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. To assess the capability of the HGC, a lymph node contrast (LNC) phantom was constructed to simulate medical scenarios of varying radioactivity concentrations and SLN size. METHODS: The phantom was constructed using two clear acrylic glass plates. The SLNs were simulated by circular wells of diameters ranging from 10 to 2.5 mm (16 wells in total) in 1 plate. The second plate contains four larger rectangular wells to simulate tissue background activity surrounding the SLNs. The activity used to simulate each SLN ranged between 4 and 0.025 MBq. The activity concentration ratio between the background and the activity injected in the SLNs was 1 : 10. The LNC phantom was placed at different depths of scattering material ranging between 5 and 40 mm. The collimator-to-source distance was 120 mm. Image acquisition times ranged from 60 to 240 s. RESULTS: Contrast-to-noise ratio analysis and full-width-at-half-maximum (FWHM) measurements of the simulated SLNs were carried out for the images obtained. Over the range of activities used, the HGC detected between 87.5 and 100% of the SLNs through 20 mm of scattering material and 75–93.75% of the SLNs through 40 mm of scattering material. The FWHM of the detected SLNs ranged between 11.93 and 14.70 mm. CONCLUSION: The HGC is capable of detecting low accumulation of activity in small SLNs, indicating its usefulness as an intraoperative imaging system during surgical SLN procedures. ADVANCES IN KNOWLEDGE: This study investigates the capability of a novel small-field-of-view (SFOV) HGC to detect low activity uptake in small SLNs. The phantom and procedure described are inexpensive and could be easily replicated and applied to any SFOV camera, to provide a comparison between systems with clinically relevant results. The British Institute of Radiology. 2016-10 2016-09-09 /pmc/articles/PMC5124810/ /pubmed/27537079 http://dx.doi.org/10.1259/bjr.20160435 Text en © 2016 The Authors. Published by the British Institute of Radiology This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 Unported License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.
spellingShingle Full Paper
Alqahtani, Mohammed S
Lees, John E
Bugby, Sarah L
Jambi, Layal K
Perkins, Alan C
Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection
title Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection
title_full Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection
title_fullStr Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection
title_full_unstemmed Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection
title_short Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection
title_sort quantitative investigation of a novel small field of view hybrid gamma camera (hgc) capability for sentinel lymph node detection
topic Full Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5124810/
https://www.ncbi.nlm.nih.gov/pubmed/27537079
http://dx.doi.org/10.1259/bjr.20160435
work_keys_str_mv AT alqahtanimohammeds quantitativeinvestigationofanovelsmallfieldofviewhybridgammacamerahgccapabilityforsentinellymphnodedetection
AT leesjohne quantitativeinvestigationofanovelsmallfieldofviewhybridgammacamerahgccapabilityforsentinellymphnodedetection
AT bugbysarahl quantitativeinvestigationofanovelsmallfieldofviewhybridgammacamerahgccapabilityforsentinellymphnodedetection
AT jambilayalk quantitativeinvestigationofanovelsmallfieldofviewhybridgammacamerahgccapabilityforsentinellymphnodedetection
AT perkinsalanc quantitativeinvestigationofanovelsmallfieldofviewhybridgammacamerahgccapabilityforsentinellymphnodedetection