Cargando…
Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype
Satisfactory functional outcomes following bronchoscopic lung volume reduction (BLVR) using endobronchial valves (EBVs) depend on the absence of collateral ventilation (CV) between the target and adjunct lobes. The Chartis system has proven to be useful for determining whether CV is present or absen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5125985/ https://www.ncbi.nlm.nih.gov/pubmed/27920518 http://dx.doi.org/10.2147/COPD.S118919 |
_version_ | 1782470036962672640 |
---|---|
author | Yin, Yan Hou, Gang Herth, Felix J Wang, Xiao-bo Wang, Qiu-yue Kang, Jian |
author_facet | Yin, Yan Hou, Gang Herth, Felix J Wang, Xiao-bo Wang, Qiu-yue Kang, Jian |
author_sort | Yin, Yan |
collection | PubMed |
description | Satisfactory functional outcomes following bronchoscopic lung volume reduction (BLVR) using endobronchial valves (EBVs) depend on the absence of collateral ventilation (CV) between the target and adjunct lobes. The Chartis system has proven to be useful for determining whether CV is present or absent, but this system can also erroneously indicate the absence of CV, which can lead to BLVR failure. Here, we describe low-flow Chartis phenotype in the target lobe resulted in difficult judgment of existence of CV. Consequently, BLVR with EBVs implanted into the right upper bronchus failed to reduce lung volume or induce atelectasis. Inserting another EBV into the right middle bronchus blocked the latent CV, which led to significant lung volume reduction in the right upper lobe (RUL) and right middle lobe (RML) and to improve the pulmonary function, 6-min walking distance, and St George respiratory questionnaire scores over a 2-week follow-up period. Low flow in the target lobe is a unique Chartis phenotype and represents the uncertainty of CV, which is a risk factor for the failure of BLVR using EBVs. Clinicians should be aware of this possibility and might be able to resolve the problem by blocking the RUL and RML between which the CV occurs. |
format | Online Article Text |
id | pubmed-5125985 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-51259852016-12-05 Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype Yin, Yan Hou, Gang Herth, Felix J Wang, Xiao-bo Wang, Qiu-yue Kang, Jian Int J Chron Obstruct Pulmon Dis Case Report Satisfactory functional outcomes following bronchoscopic lung volume reduction (BLVR) using endobronchial valves (EBVs) depend on the absence of collateral ventilation (CV) between the target and adjunct lobes. The Chartis system has proven to be useful for determining whether CV is present or absent, but this system can also erroneously indicate the absence of CV, which can lead to BLVR failure. Here, we describe low-flow Chartis phenotype in the target lobe resulted in difficult judgment of existence of CV. Consequently, BLVR with EBVs implanted into the right upper bronchus failed to reduce lung volume or induce atelectasis. Inserting another EBV into the right middle bronchus blocked the latent CV, which led to significant lung volume reduction in the right upper lobe (RUL) and right middle lobe (RML) and to improve the pulmonary function, 6-min walking distance, and St George respiratory questionnaire scores over a 2-week follow-up period. Low flow in the target lobe is a unique Chartis phenotype and represents the uncertainty of CV, which is a risk factor for the failure of BLVR using EBVs. Clinicians should be aware of this possibility and might be able to resolve the problem by blocking the RUL and RML between which the CV occurs. Dove Medical Press 2016-11-24 /pmc/articles/PMC5125985/ /pubmed/27920518 http://dx.doi.org/10.2147/COPD.S118919 Text en © 2016 Yin et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Case Report Yin, Yan Hou, Gang Herth, Felix J Wang, Xiao-bo Wang, Qiu-yue Kang, Jian Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype |
title | Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype |
title_full | Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype |
title_fullStr | Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype |
title_full_unstemmed | Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype |
title_short | Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype |
title_sort | significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow chartis phenotype |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5125985/ https://www.ncbi.nlm.nih.gov/pubmed/27920518 http://dx.doi.org/10.2147/COPD.S118919 |
work_keys_str_mv | AT yinyan significantlungvolumereductionwithendobronchialvalvesinapatientdespitethepresenceofmicrocollateralsmaskedbylowflowchartisphenotype AT hougang significantlungvolumereductionwithendobronchialvalvesinapatientdespitethepresenceofmicrocollateralsmaskedbylowflowchartisphenotype AT herthfelixj significantlungvolumereductionwithendobronchialvalvesinapatientdespitethepresenceofmicrocollateralsmaskedbylowflowchartisphenotype AT wangxiaobo significantlungvolumereductionwithendobronchialvalvesinapatientdespitethepresenceofmicrocollateralsmaskedbylowflowchartisphenotype AT wangqiuyue significantlungvolumereductionwithendobronchialvalvesinapatientdespitethepresenceofmicrocollateralsmaskedbylowflowchartisphenotype AT kangjian significantlungvolumereductionwithendobronchialvalvesinapatientdespitethepresenceofmicrocollateralsmaskedbylowflowchartisphenotype |