Cargando…
Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings
BACKGROUND: Although premature beats are a matter of concern in horses, the interpretation of equine ECG recordings is complicated by a lack of standardized analysis criteria and a limited knowledge of the normal beat-to-beat variation of equine cardiac rhythm. The purpose of this study was to deter...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5126988/ https://www.ncbi.nlm.nih.gov/pubmed/27894294 http://dx.doi.org/10.1186/s12917-016-0894-2 |
_version_ | 1782470189545160704 |
---|---|
author | Flethøj, Mette Kanters, Jørgen K. Pedersen, Philip J. Haugaard, Maria M. Carstensen, Helena Olsen, Lisbeth H. Buhl, Rikke |
author_facet | Flethøj, Mette Kanters, Jørgen K. Pedersen, Philip J. Haugaard, Maria M. Carstensen, Helena Olsen, Lisbeth H. Buhl, Rikke |
author_sort | Flethøj, Mette |
collection | PubMed |
description | BACKGROUND: Although premature beats are a matter of concern in horses, the interpretation of equine ECG recordings is complicated by a lack of standardized analysis criteria and a limited knowledge of the normal beat-to-beat variation of equine cardiac rhythm. The purpose of this study was to determine the appropriate threshold levels of maximum acceptable deviation of RR intervals in equine ECG analysis, and to evaluate a novel two-step timing algorithm by quantifying the frequency of arrhythmias in a cohort of healthy adult endurance horses. RESULTS: Beat-to-beat variation differed considerably with heart rate (HR), and an adaptable model consisting of three different HR ranges with separate threshold levels of maximum acceptable RR deviation was consequently defined. For resting HRs <60 beats/min (bpm) the threshold level of RR deviation was set at 20%, for HRs in the intermediate range between 60 and 100 bpm the threshold was 10%, and for exercising HRs >100 bpm, the threshold level was 4%. Supraventricular premature beats represented the most prevalent arrhythmia category with varying frequencies in seven horses at rest (median 7, range 2–86) and six horses during exercise (median 2, range 1–24). CONCLUSIONS: Beat-to-beat variation of equine cardiac rhythm varies according to HR, and threshold levels in equine ECG analysis should be adjusted accordingly. Standardization of the analysis criteria will enable comparisons of studies and follow-up examinations of patients. A small number of supraventricular premature beats appears to be a normal finding in endurance horses. Further studies are required to validate the findings and determine the clinical significance of premature beats in horses. |
format | Online Article Text |
id | pubmed-5126988 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-51269882016-12-08 Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings Flethøj, Mette Kanters, Jørgen K. Pedersen, Philip J. Haugaard, Maria M. Carstensen, Helena Olsen, Lisbeth H. Buhl, Rikke BMC Vet Res Research Article BACKGROUND: Although premature beats are a matter of concern in horses, the interpretation of equine ECG recordings is complicated by a lack of standardized analysis criteria and a limited knowledge of the normal beat-to-beat variation of equine cardiac rhythm. The purpose of this study was to determine the appropriate threshold levels of maximum acceptable deviation of RR intervals in equine ECG analysis, and to evaluate a novel two-step timing algorithm by quantifying the frequency of arrhythmias in a cohort of healthy adult endurance horses. RESULTS: Beat-to-beat variation differed considerably with heart rate (HR), and an adaptable model consisting of three different HR ranges with separate threshold levels of maximum acceptable RR deviation was consequently defined. For resting HRs <60 beats/min (bpm) the threshold level of RR deviation was set at 20%, for HRs in the intermediate range between 60 and 100 bpm the threshold was 10%, and for exercising HRs >100 bpm, the threshold level was 4%. Supraventricular premature beats represented the most prevalent arrhythmia category with varying frequencies in seven horses at rest (median 7, range 2–86) and six horses during exercise (median 2, range 1–24). CONCLUSIONS: Beat-to-beat variation of equine cardiac rhythm varies according to HR, and threshold levels in equine ECG analysis should be adjusted accordingly. Standardization of the analysis criteria will enable comparisons of studies and follow-up examinations of patients. A small number of supraventricular premature beats appears to be a normal finding in endurance horses. Further studies are required to validate the findings and determine the clinical significance of premature beats in horses. BioMed Central 2016-11-28 /pmc/articles/PMC5126988/ /pubmed/27894294 http://dx.doi.org/10.1186/s12917-016-0894-2 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Flethøj, Mette Kanters, Jørgen K. Pedersen, Philip J. Haugaard, Maria M. Carstensen, Helena Olsen, Lisbeth H. Buhl, Rikke Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings |
title | Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings |
title_full | Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings |
title_fullStr | Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings |
title_full_unstemmed | Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings |
title_short | Appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ECG recordings |
title_sort | appropriate threshold levels of cardiac beat-to-beat variation in semi-automatic analysis of equine ecg recordings |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5126988/ https://www.ncbi.nlm.nih.gov/pubmed/27894294 http://dx.doi.org/10.1186/s12917-016-0894-2 |
work_keys_str_mv | AT flethøjmette appropriatethresholdlevelsofcardiacbeattobeatvariationinsemiautomaticanalysisofequineecgrecordings AT kantersjørgenk appropriatethresholdlevelsofcardiacbeattobeatvariationinsemiautomaticanalysisofequineecgrecordings AT pedersenphilipj appropriatethresholdlevelsofcardiacbeattobeatvariationinsemiautomaticanalysisofequineecgrecordings AT haugaardmariam appropriatethresholdlevelsofcardiacbeattobeatvariationinsemiautomaticanalysisofequineecgrecordings AT carstensenhelena appropriatethresholdlevelsofcardiacbeattobeatvariationinsemiautomaticanalysisofequineecgrecordings AT olsenlisbethh appropriatethresholdlevelsofcardiacbeattobeatvariationinsemiautomaticanalysisofequineecgrecordings AT buhlrikke appropriatethresholdlevelsofcardiacbeattobeatvariationinsemiautomaticanalysisofequineecgrecordings |