Cargando…
Catastrophic metallosis after tumoral knee prosthesis failure: A case report
INTRODUCTION: Metallosis is a condition characterized by an infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear or failure of joint arthroplasties. PRESENTATION OF CASE: Authors describe a case of a 45-year-old man treated for an osteosarcoma of the distal fem...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5129503/ https://www.ncbi.nlm.nih.gov/pubmed/27898357 http://dx.doi.org/10.1016/j.ijscr.2016.11.023 |
_version_ | 1782470598552715264 |
---|---|
author | La Verde, Luca Fenga, Domenico Spinelli, Maria Silvia Campo, Francesco Rosario Florio, Michela Rosa, Michele Attilio |
author_facet | La Verde, Luca Fenga, Domenico Spinelli, Maria Silvia Campo, Francesco Rosario Florio, Michela Rosa, Michele Attilio |
author_sort | La Verde, Luca |
collection | PubMed |
description | INTRODUCTION: Metallosis is a condition characterized by an infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear or failure of joint arthroplasties. PRESENTATION OF CASE: Authors describe a case of a 45-year-old man treated for an osteosarcoma of the distal femur with a modular prosthesis when he was 18 years old, he developed massive metallosis with skin dyspigmentation after 17 years. His medical\surgical history was remarkable for a left tumoral knee prosthesis implanted 21 years ago. Two years before revision, the patient had a car accident with a two-points prosthesis breakage and despite the surgeon’s advice, the patient refused surgery. In two years, prosthesis malfunction caused a progressive catastrophic soft tissues infiltration of metallic debris. DISCUSSION AND CONCLUSION: Authors suggest that if prosthesis fracture is detected, revision surgery should be attempted as earlier as possible. |
format | Online Article Text |
id | pubmed-5129503 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-51295032016-12-06 Catastrophic metallosis after tumoral knee prosthesis failure: A case report La Verde, Luca Fenga, Domenico Spinelli, Maria Silvia Campo, Francesco Rosario Florio, Michela Rosa, Michele Attilio Int J Surg Case Rep Case Report INTRODUCTION: Metallosis is a condition characterized by an infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear or failure of joint arthroplasties. PRESENTATION OF CASE: Authors describe a case of a 45-year-old man treated for an osteosarcoma of the distal femur with a modular prosthesis when he was 18 years old, he developed massive metallosis with skin dyspigmentation after 17 years. His medical\surgical history was remarkable for a left tumoral knee prosthesis implanted 21 years ago. Two years before revision, the patient had a car accident with a two-points prosthesis breakage and despite the surgeon’s advice, the patient refused surgery. In two years, prosthesis malfunction caused a progressive catastrophic soft tissues infiltration of metallic debris. DISCUSSION AND CONCLUSION: Authors suggest that if prosthesis fracture is detected, revision surgery should be attempted as earlier as possible. Elsevier 2016-11-18 /pmc/articles/PMC5129503/ /pubmed/27898357 http://dx.doi.org/10.1016/j.ijscr.2016.11.023 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report La Verde, Luca Fenga, Domenico Spinelli, Maria Silvia Campo, Francesco Rosario Florio, Michela Rosa, Michele Attilio Catastrophic metallosis after tumoral knee prosthesis failure: A case report |
title | Catastrophic metallosis after tumoral knee prosthesis failure: A case report |
title_full | Catastrophic metallosis after tumoral knee prosthesis failure: A case report |
title_fullStr | Catastrophic metallosis after tumoral knee prosthesis failure: A case report |
title_full_unstemmed | Catastrophic metallosis after tumoral knee prosthesis failure: A case report |
title_short | Catastrophic metallosis after tumoral knee prosthesis failure: A case report |
title_sort | catastrophic metallosis after tumoral knee prosthesis failure: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5129503/ https://www.ncbi.nlm.nih.gov/pubmed/27898357 http://dx.doi.org/10.1016/j.ijscr.2016.11.023 |
work_keys_str_mv | AT laverdeluca catastrophicmetallosisaftertumoralkneeprosthesisfailureacasereport AT fengadomenico catastrophicmetallosisaftertumoralkneeprosthesisfailureacasereport AT spinellimariasilvia catastrophicmetallosisaftertumoralkneeprosthesisfailureacasereport AT campofrancescorosario catastrophicmetallosisaftertumoralkneeprosthesisfailureacasereport AT floriomichela catastrophicmetallosisaftertumoralkneeprosthesisfailureacasereport AT rosamicheleattilio catastrophicmetallosisaftertumoralkneeprosthesisfailureacasereport |