Esophageal perforation after perioperative transesophageal echocardiography: a case report
BACKGROUND: Transesophageal echocardiography is widely used in cardiac surgery. Transesophageal echocardiography probe insertion and manipulation can injure the esophagus. CASE PRESENTATION: A 76-year-old Asian man was admitted to our hospital for coronary artery bypass graft revascularization surge...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134105/ https://www.ncbi.nlm.nih.gov/pubmed/27906089 http://dx.doi.org/10.1186/s13256-016-1131-0 |
_version_ | 1782471403160731648 |
---|---|
author | Kim, Hyun-Chang Oh, Jung-Hyou Lee, Yong-Cheol |
author_facet | Kim, Hyun-Chang Oh, Jung-Hyou Lee, Yong-Cheol |
author_sort | Kim, Hyun-Chang |
collection | PubMed |
description | BACKGROUND: Transesophageal echocardiography is widely used in cardiac surgery. Transesophageal echocardiography probe insertion and manipulation can injure the esophagus. CASE PRESENTATION: A 76-year-old Asian man was admitted to our hospital for coronary artery bypass graft revascularization surgery. A right carotid endarterectomy was successfully performed 2 days before coronary artery bypass graft revascularization surgery. After the coronary artery bypass graft revascularization surgery was done successfully, postoperative computed tomography and esophagography revealed perforation of the middle esophagus. The patient was managed with fasting, parenteral nutrition, and intravenous antibiotics. CONCLUSIONS: Esophageal perforation can occur with transesophageal echocardiography probe insertion, even without difficulty or resistance, in patients with atherosclerotic disease. Appropriate imaging and vigilance for esophageal injury after a transesophageal echocardiography examination in patients with cardiovascular disease are necessary for appropriate diagnosis and treatment. |
format | Online Article Text |
id | pubmed-5134105 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-51341052016-12-15 Esophageal perforation after perioperative transesophageal echocardiography: a case report Kim, Hyun-Chang Oh, Jung-Hyou Lee, Yong-Cheol J Med Case Rep Case Report BACKGROUND: Transesophageal echocardiography is widely used in cardiac surgery. Transesophageal echocardiography probe insertion and manipulation can injure the esophagus. CASE PRESENTATION: A 76-year-old Asian man was admitted to our hospital for coronary artery bypass graft revascularization surgery. A right carotid endarterectomy was successfully performed 2 days before coronary artery bypass graft revascularization surgery. After the coronary artery bypass graft revascularization surgery was done successfully, postoperative computed tomography and esophagography revealed perforation of the middle esophagus. The patient was managed with fasting, parenteral nutrition, and intravenous antibiotics. CONCLUSIONS: Esophageal perforation can occur with transesophageal echocardiography probe insertion, even without difficulty or resistance, in patients with atherosclerotic disease. Appropriate imaging and vigilance for esophageal injury after a transesophageal echocardiography examination in patients with cardiovascular disease are necessary for appropriate diagnosis and treatment. BioMed Central 2016-12-01 /pmc/articles/PMC5134105/ /pubmed/27906089 http://dx.doi.org/10.1186/s13256-016-1131-0 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Kim, Hyun-Chang Oh, Jung-Hyou Lee, Yong-Cheol Esophageal perforation after perioperative transesophageal echocardiography: a case report |
title | Esophageal perforation after perioperative transesophageal echocardiography: a case report |
title_full | Esophageal perforation after perioperative transesophageal echocardiography: a case report |
title_fullStr | Esophageal perforation after perioperative transesophageal echocardiography: a case report |
title_full_unstemmed | Esophageal perforation after perioperative transesophageal echocardiography: a case report |
title_short | Esophageal perforation after perioperative transesophageal echocardiography: a case report |
title_sort | esophageal perforation after perioperative transesophageal echocardiography: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134105/ https://www.ncbi.nlm.nih.gov/pubmed/27906089 http://dx.doi.org/10.1186/s13256-016-1131-0 |
work_keys_str_mv | AT kimhyunchang esophagealperforationafterperioperativetransesophagealechocardiographyacasereport AT ohjunghyou esophagealperforationafterperioperativetransesophagealechocardiographyacasereport AT leeyongcheol esophagealperforationafterperioperativetransesophagealechocardiographyacasereport |