Development and Experimental Comparison of Low-Cost, Reliable Capacitive Touch Sensing Boards
In this study, two types of direct interface capacitive sensors, self- and mutual-capacitance, were developed and compared experimentally. Electromagnetic Compatibility (EMC) tests—International Electrotechnical Commission (IEC) 61000-4-3, IEC 61000-4-4, IEC 61000-4-6—were applied in an accredited l...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134445/ https://www.ncbi.nlm.nih.gov/pubmed/27792202 http://dx.doi.org/10.3390/s16111786 |
Sumario: | In this study, two types of direct interface capacitive sensors, self- and mutual-capacitance, were developed and compared experimentally. Electromagnetic Compatibility (EMC) tests—International Electrotechnical Commission (IEC) 61000-4-3, IEC 61000-4-4, IEC 61000-4-6—were applied in an accredited laboratory to measure the immunity of the sensors against radiated and conducted interference. The frequency hopping algorithm could be implemented for the mutual-capacitance sensor without using any particular circuit. The effects of EMC disturbance were detected by means of a new noise detection algorithm and when the signal-to-noise ratio (SNR) became lower, the operation frequency of the sensors switched to an undisturbed frequency to ensure safe operation. For this purpose, a new noise detection algorithm was developed and frequency hopping was performed with a standard controller. Both cards were tested under several conditions and their performances compared. |
---|