Cargando…

Whispering Gallery Mode Thermometry

This paper presents a state-of-the-art whispering gallery mode (WGM) thermometer system, which could replace platinum resistance thermometers currently used in many industrial applications, thus overcoming some of their well-known limitations and their potential for providing lower measurement uncer...

Descripción completa

Detalles Bibliográficos
Autores principales: Corbellini, Simone, Ramella, Chiara, Yu, Lili, Pirola, Marco, Fernicola, Vito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134473/
https://www.ncbi.nlm.nih.gov/pubmed/27801868
http://dx.doi.org/10.3390/s16111814
_version_ 1782471460431855616
author Corbellini, Simone
Ramella, Chiara
Yu, Lili
Pirola, Marco
Fernicola, Vito
author_facet Corbellini, Simone
Ramella, Chiara
Yu, Lili
Pirola, Marco
Fernicola, Vito
author_sort Corbellini, Simone
collection PubMed
description This paper presents a state-of-the-art whispering gallery mode (WGM) thermometer system, which could replace platinum resistance thermometers currently used in many industrial applications, thus overcoming some of their well-known limitations and their potential for providing lower measurement uncertainty. The temperature-sensing element is a sapphire-crystal-based whispering gallery mode resonator with the main resonant modes between 10 GHz and 20 GHz. In particular, it was found that the WGM around 13.6 GHz maximizes measurement performance, affording sub-millikelvin resolution and temperature stability of better than 1 mK at 0 °C. The thermometer system was made portable and low-cost by developing an ad hoc interrogation system (hardware and software) able to achieve an accuracy in the order of a few parts in 10(9) in the determination of resonance frequencies. Herein we report the experimental assessment of the measurement stability, repeatability and resolution, and the calibration of the thermometer in the temperature range from −74 °C to 85 °C. The combined standard uncertainty for a single temperature calibration point is found to be within 5 mK (i.e., comparable with state-of-the-art for industrial thermometry), and is mainly due to the employed calibration setup. The uncertainty contribution of the WGM thermometer alone is within a millikelvin.
format Online
Article
Text
id pubmed-5134473
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-51344732017-01-03 Whispering Gallery Mode Thermometry Corbellini, Simone Ramella, Chiara Yu, Lili Pirola, Marco Fernicola, Vito Sensors (Basel) Article This paper presents a state-of-the-art whispering gallery mode (WGM) thermometer system, which could replace platinum resistance thermometers currently used in many industrial applications, thus overcoming some of their well-known limitations and their potential for providing lower measurement uncertainty. The temperature-sensing element is a sapphire-crystal-based whispering gallery mode resonator with the main resonant modes between 10 GHz and 20 GHz. In particular, it was found that the WGM around 13.6 GHz maximizes measurement performance, affording sub-millikelvin resolution and temperature stability of better than 1 mK at 0 °C. The thermometer system was made portable and low-cost by developing an ad hoc interrogation system (hardware and software) able to achieve an accuracy in the order of a few parts in 10(9) in the determination of resonance frequencies. Herein we report the experimental assessment of the measurement stability, repeatability and resolution, and the calibration of the thermometer in the temperature range from −74 °C to 85 °C. The combined standard uncertainty for a single temperature calibration point is found to be within 5 mK (i.e., comparable with state-of-the-art for industrial thermometry), and is mainly due to the employed calibration setup. The uncertainty contribution of the WGM thermometer alone is within a millikelvin. MDPI 2016-10-29 /pmc/articles/PMC5134473/ /pubmed/27801868 http://dx.doi.org/10.3390/s16111814 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Corbellini, Simone
Ramella, Chiara
Yu, Lili
Pirola, Marco
Fernicola, Vito
Whispering Gallery Mode Thermometry
title Whispering Gallery Mode Thermometry
title_full Whispering Gallery Mode Thermometry
title_fullStr Whispering Gallery Mode Thermometry
title_full_unstemmed Whispering Gallery Mode Thermometry
title_short Whispering Gallery Mode Thermometry
title_sort whispering gallery mode thermometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134473/
https://www.ncbi.nlm.nih.gov/pubmed/27801868
http://dx.doi.org/10.3390/s16111814
work_keys_str_mv AT corbellinisimone whisperinggallerymodethermometry
AT ramellachiara whisperinggallerymodethermometry
AT yulili whisperinggallerymodethermometry
AT pirolamarco whisperinggallerymodethermometry
AT fernicolavito whisperinggallerymodethermometry