Cargando…
A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers
A method is developed to accurately determine the spatial impulse response at the specifically discretized observation points in the radiated field of 1-D linear ultrasonic phased array transducers with great efficiency. In contrast, the previously adopted solutions only optimize the calculation pro...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134532/ https://www.ncbi.nlm.nih.gov/pubmed/27834799 http://dx.doi.org/10.3390/s16111873 |
_version_ | 1782471474216435712 |
---|---|
author | Zou, Cheng Sun, Zhenguo Cai, Dong Muhammad, Salman Zhang, Wenzeng Chen, Qiang |
author_facet | Zou, Cheng Sun, Zhenguo Cai, Dong Muhammad, Salman Zhang, Wenzeng Chen, Qiang |
author_sort | Zou, Cheng |
collection | PubMed |
description | A method is developed to accurately determine the spatial impulse response at the specifically discretized observation points in the radiated field of 1-D linear ultrasonic phased array transducers with great efficiency. In contrast, the previously adopted solutions only optimize the calculation procedure for a single rectangular transducer and required approximation considerations or nonlinear calculation. In this research, an algorithm that follows an alternative approach to expedite the calculation of the spatial impulse response of a rectangular linear array is presented. The key assumption for this algorithm is that the transducer apertures are identical and linearly distributed on an infinite rigid plane baffled with the same pitch. Two points in the observation field, which have the same position relative to two transducer apertures, share the same spatial impulse response that contributed from corresponding transducer, respectively. The observation field is discretized specifically to meet the relationship of equality. The analytical expressions of the proposed algorithm, based on the specific selection of the observation points, are derived to remove redundant calculations. In order to measure the proposed methodology, the simulation results obtained from the proposed method and the classical summation method are compared. The outcomes demonstrate that the proposed strategy can speed up the calculation procedure since it accelerates the speed-up ratio which relies upon the number of discrete points and the number of the array transducers. This development will be valuable in the development of advanced and faster linear ultrasonic phased array systems. |
format | Online Article Text |
id | pubmed-5134532 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-51345322017-01-03 A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers Zou, Cheng Sun, Zhenguo Cai, Dong Muhammad, Salman Zhang, Wenzeng Chen, Qiang Sensors (Basel) Article A method is developed to accurately determine the spatial impulse response at the specifically discretized observation points in the radiated field of 1-D linear ultrasonic phased array transducers with great efficiency. In contrast, the previously adopted solutions only optimize the calculation procedure for a single rectangular transducer and required approximation considerations or nonlinear calculation. In this research, an algorithm that follows an alternative approach to expedite the calculation of the spatial impulse response of a rectangular linear array is presented. The key assumption for this algorithm is that the transducer apertures are identical and linearly distributed on an infinite rigid plane baffled with the same pitch. Two points in the observation field, which have the same position relative to two transducer apertures, share the same spatial impulse response that contributed from corresponding transducer, respectively. The observation field is discretized specifically to meet the relationship of equality. The analytical expressions of the proposed algorithm, based on the specific selection of the observation points, are derived to remove redundant calculations. In order to measure the proposed methodology, the simulation results obtained from the proposed method and the classical summation method are compared. The outcomes demonstrate that the proposed strategy can speed up the calculation procedure since it accelerates the speed-up ratio which relies upon the number of discrete points and the number of the array transducers. This development will be valuable in the development of advanced and faster linear ultrasonic phased array systems. MDPI 2016-11-08 /pmc/articles/PMC5134532/ /pubmed/27834799 http://dx.doi.org/10.3390/s16111873 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zou, Cheng Sun, Zhenguo Cai, Dong Muhammad, Salman Zhang, Wenzeng Chen, Qiang A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers |
title | A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers |
title_full | A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers |
title_fullStr | A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers |
title_full_unstemmed | A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers |
title_short | A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers |
title_sort | fast method to calculate the spatial impulse response for 1-d linear ultrasonic phased array transducers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134532/ https://www.ncbi.nlm.nih.gov/pubmed/27834799 http://dx.doi.org/10.3390/s16111873 |
work_keys_str_mv | AT zoucheng afastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT sunzhenguo afastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT caidong afastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT muhammadsalman afastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT zhangwenzeng afastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT chenqiang afastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT zoucheng fastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT sunzhenguo fastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT caidong fastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT muhammadsalman fastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT zhangwenzeng fastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers AT chenqiang fastmethodtocalculatethespatialimpulseresponsefor1dlinearultrasonicphasedarraytransducers |