Cargando…
The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols
The article presents the results of the detection of low-concentration C1–C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134540/ https://www.ncbi.nlm.nih.gov/pubmed/27834879 http://dx.doi.org/10.3390/s16111881 |
_version_ | 1782471476067172352 |
---|---|
author | Suchorska-Woźniak, Patrycja Rac, Olga Fiedot, Marta Teterycz, Helena |
author_facet | Suchorska-Woźniak, Patrycja Rac, Olga Fiedot, Marta Teterycz, Helena |
author_sort | Suchorska-Woźniak, Patrycja |
collection | PubMed |
description | The article presents the results of the detection of low-concentration C1–C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter of the single tube ranges from several to tens of nanometers. The sepiolite layer itself demonstrated no chemical activity in the presence of volatile organic compounds (VOC), and the passive filter made of this material did not modify the chemical composition of the gaseous atmosphere diffusing to the gas-sensitive layer. The test results revealed that the structural remodelling of the sepiolite that occurs under the influence of temperature, as well as the effect of the filter (a compound with ionic bonds) with molecules of water, has a significant impact on the improvement of the sensitivity of the sensor in relation to volatile organic compounds when compared to the sensor without a filter. |
format | Online Article Text |
id | pubmed-5134540 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-51345402017-01-03 The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols Suchorska-Woźniak, Patrycja Rac, Olga Fiedot, Marta Teterycz, Helena Sensors (Basel) Article The article presents the results of the detection of low-concentration C1–C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter of the single tube ranges from several to tens of nanometers. The sepiolite layer itself demonstrated no chemical activity in the presence of volatile organic compounds (VOC), and the passive filter made of this material did not modify the chemical composition of the gaseous atmosphere diffusing to the gas-sensitive layer. The test results revealed that the structural remodelling of the sepiolite that occurs under the influence of temperature, as well as the effect of the filter (a compound with ionic bonds) with molecules of water, has a significant impact on the improvement of the sensitivity of the sensor in relation to volatile organic compounds when compared to the sensor without a filter. MDPI 2016-11-09 /pmc/articles/PMC5134540/ /pubmed/27834879 http://dx.doi.org/10.3390/s16111881 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Suchorska-Woźniak, Patrycja Rac, Olga Fiedot, Marta Teterycz, Helena The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols |
title | The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols |
title_full | The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols |
title_fullStr | The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols |
title_full_unstemmed | The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols |
title_short | The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols |
title_sort | impact of sepiolite on sensor parameters during the detection of low concentrations of alcohols |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134540/ https://www.ncbi.nlm.nih.gov/pubmed/27834879 http://dx.doi.org/10.3390/s16111881 |
work_keys_str_mv | AT suchorskawozniakpatrycja theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols AT racolga theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols AT fiedotmarta theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols AT teteryczhelena theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols AT suchorskawozniakpatrycja impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols AT racolga impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols AT fiedotmarta impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols AT teteryczhelena impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols |