Cargando…

The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols

The article presents the results of the detection of low-concentration C1–C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter...

Descripción completa

Detalles Bibliográficos
Autores principales: Suchorska-Woźniak, Patrycja, Rac, Olga, Fiedot, Marta, Teterycz, Helena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134540/
https://www.ncbi.nlm.nih.gov/pubmed/27834879
http://dx.doi.org/10.3390/s16111881
_version_ 1782471476067172352
author Suchorska-Woźniak, Patrycja
Rac, Olga
Fiedot, Marta
Teterycz, Helena
author_facet Suchorska-Woźniak, Patrycja
Rac, Olga
Fiedot, Marta
Teterycz, Helena
author_sort Suchorska-Woźniak, Patrycja
collection PubMed
description The article presents the results of the detection of low-concentration C1–C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter of the single tube ranges from several to tens of nanometers. The sepiolite layer itself demonstrated no chemical activity in the presence of volatile organic compounds (VOC), and the passive filter made of this material did not modify the chemical composition of the gaseous atmosphere diffusing to the gas-sensitive layer. The test results revealed that the structural remodelling of the sepiolite that occurs under the influence of temperature, as well as the effect of the filter (a compound with ionic bonds) with molecules of water, has a significant impact on the improvement of the sensitivity of the sensor in relation to volatile organic compounds when compared to the sensor without a filter.
format Online
Article
Text
id pubmed-5134540
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-51345402017-01-03 The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols Suchorska-Woźniak, Patrycja Rac, Olga Fiedot, Marta Teterycz, Helena Sensors (Basel) Article The article presents the results of the detection of low-concentration C1–C4 alcohols using a planar sensor, in which a sepiolite filter was applied next to the gas-sensitive layer based on tin dioxide. The sepiolite layer is composed of tubes that have a length of several microns, and the diameter of the single tube ranges from several to tens of nanometers. The sepiolite layer itself demonstrated no chemical activity in the presence of volatile organic compounds (VOC), and the passive filter made of this material did not modify the chemical composition of the gaseous atmosphere diffusing to the gas-sensitive layer. The test results revealed that the structural remodelling of the sepiolite that occurs under the influence of temperature, as well as the effect of the filter (a compound with ionic bonds) with molecules of water, has a significant impact on the improvement of the sensitivity of the sensor in relation to volatile organic compounds when compared to the sensor without a filter. MDPI 2016-11-09 /pmc/articles/PMC5134540/ /pubmed/27834879 http://dx.doi.org/10.3390/s16111881 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Suchorska-Woźniak, Patrycja
Rac, Olga
Fiedot, Marta
Teterycz, Helena
The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols
title The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols
title_full The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols
title_fullStr The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols
title_full_unstemmed The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols
title_short The Impact of Sepiolite on Sensor Parameters during the Detection of Low Concentrations of Alcohols
title_sort impact of sepiolite on sensor parameters during the detection of low concentrations of alcohols
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134540/
https://www.ncbi.nlm.nih.gov/pubmed/27834879
http://dx.doi.org/10.3390/s16111881
work_keys_str_mv AT suchorskawozniakpatrycja theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols
AT racolga theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols
AT fiedotmarta theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols
AT teteryczhelena theimpactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols
AT suchorskawozniakpatrycja impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols
AT racolga impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols
AT fiedotmarta impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols
AT teteryczhelena impactofsepioliteonsensorparametersduringthedetectionoflowconcentrationsofalcohols