Cargando…

The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus

The measurement of wellbore annulus gas–liquid two-phase flow in CBM (coalbed methane) wells is of great significance for reasonably developing gas drainage and extraction processes, estimating CBM output, judging the operating conditions of CBM wells and analyzing stratum conditions. Hence, a speci...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Chuan, Wen, Guojun, Han, Lei, Wu, Xiaoming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134602/
https://www.ncbi.nlm.nih.gov/pubmed/27869708
http://dx.doi.org/10.3390/s16111943
_version_ 1782471490449440768
author Wu, Chuan
Wen, Guojun
Han, Lei
Wu, Xiaoming
author_facet Wu, Chuan
Wen, Guojun
Han, Lei
Wu, Xiaoming
author_sort Wu, Chuan
collection PubMed
description The measurement of wellbore annulus gas–liquid two-phase flow in CBM (coalbed methane) wells is of great significance for reasonably developing gas drainage and extraction processes, estimating CBM output, judging the operating conditions of CBM wells and analyzing stratum conditions. Hence, a specially designed sensor is urgently needed for real-time measurement of gas–liquid two-phase flow in CBM wellbore annulus. Existing flow sensors fail to meet the requirements of the operating conditions of CBM wellbore annulus due to such factors as an inapplicable measurement principle, larger size, poor sealability, high installation accuracy, and higher requirements for fluid media. Therefore, based on the principle of a target flowmeter, this paper designs a new two-phase flow sensor that can identify and automatically calibrate different flow patterns of two-phase flows. Upon the successful development of the new flow sensor, lab and field tests were carried out, and the results show that the newly designed sensor, with a measurement accuracy of ±2.5%, can adapt to the operating conditions of CBM wells and is reliable for long-term work.
format Online
Article
Text
id pubmed-5134602
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-51346022017-01-03 The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus Wu, Chuan Wen, Guojun Han, Lei Wu, Xiaoming Sensors (Basel) Article The measurement of wellbore annulus gas–liquid two-phase flow in CBM (coalbed methane) wells is of great significance for reasonably developing gas drainage and extraction processes, estimating CBM output, judging the operating conditions of CBM wells and analyzing stratum conditions. Hence, a specially designed sensor is urgently needed for real-time measurement of gas–liquid two-phase flow in CBM wellbore annulus. Existing flow sensors fail to meet the requirements of the operating conditions of CBM wellbore annulus due to such factors as an inapplicable measurement principle, larger size, poor sealability, high installation accuracy, and higher requirements for fluid media. Therefore, based on the principle of a target flowmeter, this paper designs a new two-phase flow sensor that can identify and automatically calibrate different flow patterns of two-phase flows. Upon the successful development of the new flow sensor, lab and field tests were carried out, and the results show that the newly designed sensor, with a measurement accuracy of ±2.5%, can adapt to the operating conditions of CBM wells and is reliable for long-term work. MDPI 2016-11-18 /pmc/articles/PMC5134602/ /pubmed/27869708 http://dx.doi.org/10.3390/s16111943 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wu, Chuan
Wen, Guojun
Han, Lei
Wu, Xiaoming
The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus
title The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus
title_full The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus
title_fullStr The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus
title_full_unstemmed The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus
title_short The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus
title_sort development of a gas–liquid two-phase flow sensor applicable to cbm wellbore annulus
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134602/
https://www.ncbi.nlm.nih.gov/pubmed/27869708
http://dx.doi.org/10.3390/s16111943
work_keys_str_mv AT wuchuan thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus
AT wenguojun thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus
AT hanlei thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus
AT wuxiaoming thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus
AT wuchuan developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus
AT wenguojun developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus
AT hanlei developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus
AT wuxiaoming developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus