Cargando…
The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus
The measurement of wellbore annulus gas–liquid two-phase flow in CBM (coalbed methane) wells is of great significance for reasonably developing gas drainage and extraction processes, estimating CBM output, judging the operating conditions of CBM wells and analyzing stratum conditions. Hence, a speci...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134602/ https://www.ncbi.nlm.nih.gov/pubmed/27869708 http://dx.doi.org/10.3390/s16111943 |
_version_ | 1782471490449440768 |
---|---|
author | Wu, Chuan Wen, Guojun Han, Lei Wu, Xiaoming |
author_facet | Wu, Chuan Wen, Guojun Han, Lei Wu, Xiaoming |
author_sort | Wu, Chuan |
collection | PubMed |
description | The measurement of wellbore annulus gas–liquid two-phase flow in CBM (coalbed methane) wells is of great significance for reasonably developing gas drainage and extraction processes, estimating CBM output, judging the operating conditions of CBM wells and analyzing stratum conditions. Hence, a specially designed sensor is urgently needed for real-time measurement of gas–liquid two-phase flow in CBM wellbore annulus. Existing flow sensors fail to meet the requirements of the operating conditions of CBM wellbore annulus due to such factors as an inapplicable measurement principle, larger size, poor sealability, high installation accuracy, and higher requirements for fluid media. Therefore, based on the principle of a target flowmeter, this paper designs a new two-phase flow sensor that can identify and automatically calibrate different flow patterns of two-phase flows. Upon the successful development of the new flow sensor, lab and field tests were carried out, and the results show that the newly designed sensor, with a measurement accuracy of ±2.5%, can adapt to the operating conditions of CBM wells and is reliable for long-term work. |
format | Online Article Text |
id | pubmed-5134602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-51346022017-01-03 The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus Wu, Chuan Wen, Guojun Han, Lei Wu, Xiaoming Sensors (Basel) Article The measurement of wellbore annulus gas–liquid two-phase flow in CBM (coalbed methane) wells is of great significance for reasonably developing gas drainage and extraction processes, estimating CBM output, judging the operating conditions of CBM wells and analyzing stratum conditions. Hence, a specially designed sensor is urgently needed for real-time measurement of gas–liquid two-phase flow in CBM wellbore annulus. Existing flow sensors fail to meet the requirements of the operating conditions of CBM wellbore annulus due to such factors as an inapplicable measurement principle, larger size, poor sealability, high installation accuracy, and higher requirements for fluid media. Therefore, based on the principle of a target flowmeter, this paper designs a new two-phase flow sensor that can identify and automatically calibrate different flow patterns of two-phase flows. Upon the successful development of the new flow sensor, lab and field tests were carried out, and the results show that the newly designed sensor, with a measurement accuracy of ±2.5%, can adapt to the operating conditions of CBM wells and is reliable for long-term work. MDPI 2016-11-18 /pmc/articles/PMC5134602/ /pubmed/27869708 http://dx.doi.org/10.3390/s16111943 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wu, Chuan Wen, Guojun Han, Lei Wu, Xiaoming The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus |
title | The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus |
title_full | The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus |
title_fullStr | The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus |
title_full_unstemmed | The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus |
title_short | The Development of a Gas–Liquid Two-Phase Flow Sensor Applicable to CBM Wellbore Annulus |
title_sort | development of a gas–liquid two-phase flow sensor applicable to cbm wellbore annulus |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134602/ https://www.ncbi.nlm.nih.gov/pubmed/27869708 http://dx.doi.org/10.3390/s16111943 |
work_keys_str_mv | AT wuchuan thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus AT wenguojun thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus AT hanlei thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus AT wuxiaoming thedevelopmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus AT wuchuan developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus AT wenguojun developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus AT hanlei developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus AT wuxiaoming developmentofagasliquidtwophaseflowsensorapplicabletocbmwellboreannulus |