Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays

The use of dried blood spots (DBS) instead of plasma as a specimen type for HIV-1 viral load (VL) testing facilitates the decentralization of specimen collection and can increase access to VL testing in resource-limited settings. The performance of DBS for VL testing is lower, however, when compared...

Descripción completa

Detalles Bibliográficos
Autores principales: Pannus, Pieter, Claus, Maarten, Gonzalez, Maria Mercedes Perez, Ford, Nathan, Fransen, Katrien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134769/
https://www.ncbi.nlm.nih.gov/pubmed/27902602
http://dx.doi.org/10.1097/MD.0000000000005475
_version_ 1782471517855023104
author Pannus, Pieter
Claus, Maarten
Gonzalez, Maria Mercedes Perez
Ford, Nathan
Fransen, Katrien
author_facet Pannus, Pieter
Claus, Maarten
Gonzalez, Maria Mercedes Perez
Ford, Nathan
Fransen, Katrien
author_sort Pannus, Pieter
collection PubMed
description The use of dried blood spots (DBS) instead of plasma as a specimen type for HIV-1 viral load (VL) testing facilitates the decentralization of specimen collection and can increase access to VL testing in resource-limited settings. The performance of DBS for VL testing is lower, however, when compared to the gold standard sample type plasma. In this diagnostic accuracy study, we evaluated 3 VL assays with DBS. Participants were recruited between August 2012 and April 2015. Both plasma and DBS specimens were prepared and tested for HIV-1 VL with the Roche CAP/CTM HIV-1 test v2.0, the Abbott RealTime HIV-1, and the bioMérieux NucliSENS EasyQ HIV-1 v2.0. Sensitivity and specificity to detect treatment failure at a threshold of 1000 cps/mL with DBS were determined. A total of 272 HIV-positive patients and 51 HIV-negative people were recruited in the study. The mean difference or bias between plasma and DBS VL was <0.5 log cps/mL with all 3 assays but >25% of the specimens differed by >0.5 log cps/mL. All 3 assays had comparable sensitivities around 80% and specificities around 90%. Upward misclassification rates were around 10%, but downward misclassification rates ranged from 20.3% to 23.6%. Differences in between assays were not statistically significant (P > 0.1). The 3 VL assays evaluated had suboptimal performance with DBS but still performed better than immunological or clinical monitoring. Even after the introduction of the much-anticipated point-of-care VL devices, it is expected that DBS will remain important as a complementary option for supporting access to VL monitoring, particularly in rural, resource-limited settings. Manufacturers should accelerate efforts to develop more reliable, sensitive and specific methods to test VL on DBS specimens.
format Online
Article
Text
id pubmed-5134769
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-51347692016-12-22 Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays Pannus, Pieter Claus, Maarten Gonzalez, Maria Mercedes Perez Ford, Nathan Fransen, Katrien Medicine (Baltimore) 4850 The use of dried blood spots (DBS) instead of plasma as a specimen type for HIV-1 viral load (VL) testing facilitates the decentralization of specimen collection and can increase access to VL testing in resource-limited settings. The performance of DBS for VL testing is lower, however, when compared to the gold standard sample type plasma. In this diagnostic accuracy study, we evaluated 3 VL assays with DBS. Participants were recruited between August 2012 and April 2015. Both plasma and DBS specimens were prepared and tested for HIV-1 VL with the Roche CAP/CTM HIV-1 test v2.0, the Abbott RealTime HIV-1, and the bioMérieux NucliSENS EasyQ HIV-1 v2.0. Sensitivity and specificity to detect treatment failure at a threshold of 1000 cps/mL with DBS were determined. A total of 272 HIV-positive patients and 51 HIV-negative people were recruited in the study. The mean difference or bias between plasma and DBS VL was <0.5 log cps/mL with all 3 assays but >25% of the specimens differed by >0.5 log cps/mL. All 3 assays had comparable sensitivities around 80% and specificities around 90%. Upward misclassification rates were around 10%, but downward misclassification rates ranged from 20.3% to 23.6%. Differences in between assays were not statistically significant (P > 0.1). The 3 VL assays evaluated had suboptimal performance with DBS but still performed better than immunological or clinical monitoring. Even after the introduction of the much-anticipated point-of-care VL devices, it is expected that DBS will remain important as a complementary option for supporting access to VL monitoring, particularly in rural, resource-limited settings. Manufacturers should accelerate efforts to develop more reliable, sensitive and specific methods to test VL on DBS specimens. Wolters Kluwer Health 2016-12-02 /pmc/articles/PMC5134769/ /pubmed/27902602 http://dx.doi.org/10.1097/MD.0000000000005475 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-No Derivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 4850
Pannus, Pieter
Claus, Maarten
Gonzalez, Maria Mercedes Perez
Ford, Nathan
Fransen, Katrien
Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays
title Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays
title_full Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays
title_fullStr Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays
title_full_unstemmed Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays
title_short Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification: A laboratory assessment of 3 commercial assays
title_sort sensitivity and specificity of dried blood spots for hiv-1 viral load quantification: a laboratory assessment of 3 commercial assays
topic 4850
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5134769/
https://www.ncbi.nlm.nih.gov/pubmed/27902602
http://dx.doi.org/10.1097/MD.0000000000005475
work_keys_str_mv AT pannuspieter sensitivityandspecificityofdriedbloodspotsforhiv1viralloadquantificationalaboratoryassessmentof3commercialassays
AT clausmaarten sensitivityandspecificityofdriedbloodspotsforhiv1viralloadquantificationalaboratoryassessmentof3commercialassays
AT gonzalezmariamercedesperez sensitivityandspecificityofdriedbloodspotsforhiv1viralloadquantificationalaboratoryassessmentof3commercialassays
AT fordnathan sensitivityandspecificityofdriedbloodspotsforhiv1viralloadquantificationalaboratoryassessmentof3commercialassays
AT fransenkatrien sensitivityandspecificityofdriedbloodspotsforhiv1viralloadquantificationalaboratoryassessmentof3commercialassays