Cargando…
Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients
BACKGROUND: Agreement between spot and 24-hour urine protein measurements is poor in kidney transplant recipients. We investigated whether using formulae to estimate creatinine excretion rate (eCER), rather than assuming a standard creatinine excretion rate, would improve the estimation of proteinur...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5135043/ https://www.ncbi.nlm.nih.gov/pubmed/27911917 http://dx.doi.org/10.1371/journal.pone.0166547 |
_version_ | 1782471559672233984 |
---|---|
author | Wang, Michael Ke White, Christine Akbari, Ayub Brown, Pierre Hussain, Naser Hiremath, Swapnil Knoll, Greg |
author_facet | Wang, Michael Ke White, Christine Akbari, Ayub Brown, Pierre Hussain, Naser Hiremath, Swapnil Knoll, Greg |
author_sort | Wang, Michael Ke |
collection | PubMed |
description | BACKGROUND: Agreement between spot and 24-hour urine protein measurements is poor in kidney transplant recipients. We investigated whether using formulae to estimate creatinine excretion rate (eCER), rather than assuming a standard creatinine excretion rate, would improve the estimation of proteinuria from spot urine samples in kidney transplant recipients. METHODS: We measured 24 hour urine protein and albumin and spot albumin:creatinine (ACR) and spot protein:creatinine (PCR) in 181 Kidney transplant recipients.” We utilized 6 different published formulae (Fotheringham, CKD-EPI, Cockcroft-Gault, Walser, Goldwasser and Rule) to estimate eCER and from it calculated estimated albumin and protein excretion rate (eAER and ePER). Bias, precision and accuracy (within 15%, 30% and 50%) of ACR, PCR, eAER, ePER were compared to 24-hour urine protein and albumin. RESULTS: ACR and PCR significantly underestimated 24-hour albumin and protein excretion (ACR Bias (IQR), -5.9 mg/day; p< 0.01; PCR Bias, (IQR), -35.2 mg/day; p<0.01). None of the formulae used to calculate eAER or ePER had a bias that was significantly different from the 24-hour collection (eAER and ePER bias: Fotheringham -0.3 and 7.2, CKD-EPI 0.3 and 13.5, Cockcroft-Gault -3.2 and -13.9, Walser -1.7 and 3.1, Goldwasser -1.3 and -0.5, Rule -0.6 and 4.2 mg/day respectively. The accuracy for ACR and PCR were lower (within 30% being 38% and 43% respectively) than the corresponding values estimated by utilizing eCER (for eAER 46% to 49% and ePER 46–54%). CONCLUSION: Utilizing estimated creatinine excretion to calculate eAER and ePER improves the estimation of 24-hour albuminuria/proteinuria with spot urine samples in kidney transplant recipients. |
format | Online Article Text |
id | pubmed-5135043 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-51350432016-12-21 Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients Wang, Michael Ke White, Christine Akbari, Ayub Brown, Pierre Hussain, Naser Hiremath, Swapnil Knoll, Greg PLoS One Research Article BACKGROUND: Agreement between spot and 24-hour urine protein measurements is poor in kidney transplant recipients. We investigated whether using formulae to estimate creatinine excretion rate (eCER), rather than assuming a standard creatinine excretion rate, would improve the estimation of proteinuria from spot urine samples in kidney transplant recipients. METHODS: We measured 24 hour urine protein and albumin and spot albumin:creatinine (ACR) and spot protein:creatinine (PCR) in 181 Kidney transplant recipients.” We utilized 6 different published formulae (Fotheringham, CKD-EPI, Cockcroft-Gault, Walser, Goldwasser and Rule) to estimate eCER and from it calculated estimated albumin and protein excretion rate (eAER and ePER). Bias, precision and accuracy (within 15%, 30% and 50%) of ACR, PCR, eAER, ePER were compared to 24-hour urine protein and albumin. RESULTS: ACR and PCR significantly underestimated 24-hour albumin and protein excretion (ACR Bias (IQR), -5.9 mg/day; p< 0.01; PCR Bias, (IQR), -35.2 mg/day; p<0.01). None of the formulae used to calculate eAER or ePER had a bias that was significantly different from the 24-hour collection (eAER and ePER bias: Fotheringham -0.3 and 7.2, CKD-EPI 0.3 and 13.5, Cockcroft-Gault -3.2 and -13.9, Walser -1.7 and 3.1, Goldwasser -1.3 and -0.5, Rule -0.6 and 4.2 mg/day respectively. The accuracy for ACR and PCR were lower (within 30% being 38% and 43% respectively) than the corresponding values estimated by utilizing eCER (for eAER 46% to 49% and ePER 46–54%). CONCLUSION: Utilizing estimated creatinine excretion to calculate eAER and ePER improves the estimation of 24-hour albuminuria/proteinuria with spot urine samples in kidney transplant recipients. Public Library of Science 2016-12-02 /pmc/articles/PMC5135043/ /pubmed/27911917 http://dx.doi.org/10.1371/journal.pone.0166547 Text en © 2016 Wang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Wang, Michael Ke White, Christine Akbari, Ayub Brown, Pierre Hussain, Naser Hiremath, Swapnil Knoll, Greg Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients |
title | Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients |
title_full | Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients |
title_fullStr | Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients |
title_full_unstemmed | Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients |
title_short | Utilizing Estimated Creatinine Excretion to Improve the Performance of Spot Urine Samples for the Determination of Proteinuria in Kidney Transplant Recipients |
title_sort | utilizing estimated creatinine excretion to improve the performance of spot urine samples for the determination of proteinuria in kidney transplant recipients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5135043/ https://www.ncbi.nlm.nih.gov/pubmed/27911917 http://dx.doi.org/10.1371/journal.pone.0166547 |
work_keys_str_mv | AT wangmichaelke utilizingestimatedcreatinineexcretiontoimprovetheperformanceofspoturinesamplesforthedeterminationofproteinuriainkidneytransplantrecipients AT whitechristine utilizingestimatedcreatinineexcretiontoimprovetheperformanceofspoturinesamplesforthedeterminationofproteinuriainkidneytransplantrecipients AT akbariayub utilizingestimatedcreatinineexcretiontoimprovetheperformanceofspoturinesamplesforthedeterminationofproteinuriainkidneytransplantrecipients AT brownpierre utilizingestimatedcreatinineexcretiontoimprovetheperformanceofspoturinesamplesforthedeterminationofproteinuriainkidneytransplantrecipients AT hussainnaser utilizingestimatedcreatinineexcretiontoimprovetheperformanceofspoturinesamplesforthedeterminationofproteinuriainkidneytransplantrecipients AT hiremathswapnil utilizingestimatedcreatinineexcretiontoimprovetheperformanceofspoturinesamplesforthedeterminationofproteinuriainkidneytransplantrecipients AT knollgreg utilizingestimatedcreatinineexcretiontoimprovetheperformanceofspoturinesamplesforthedeterminationofproteinuriainkidneytransplantrecipients |