Cargando…

A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations

BACKGROUND: A very simple, sensitive, and accurate high-performance liquid chromatography (HPLC) method with ultraviolet detector was developed and applied to determine ciprofloxacin in human plasma following administration of a gastroretentive formulation developed in our laboratory. MATERIALS AND...

Descripción completa

Detalles Bibliográficos
Autores principales: Emami, Jaber, Rezazadeh, Mahboubeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137234/
https://www.ncbi.nlm.nih.gov/pubmed/27995102
http://dx.doi.org/10.4103/2277-9175.190995
_version_ 1782471877443190784
author Emami, Jaber
Rezazadeh, Mahboubeh
author_facet Emami, Jaber
Rezazadeh, Mahboubeh
author_sort Emami, Jaber
collection PubMed
description BACKGROUND: A very simple, sensitive, and accurate high-performance liquid chromatography (HPLC) method with ultraviolet detector was developed and applied to determine ciprofloxacin in human plasma following administration of a gastroretentive formulation developed in our laboratory. MATERIALS AND METHODS: HPLC analysis was performed on a C(18) μ-Bondapack column (250 mm × 3.9 mm) using acetonitrile: potassium dihydrogen phosphate solution 0.1 M (20:80, v/v, pH 3) at a flow rate of 1.5 ml/min and eluate was monitored at 276 nm. After addition of phenacetin as internal standard, plasma samples were treated with 0.1 M phosphate buffer (pH: 7) and followed by extraction with dichloromethane. The method was validated for linearity, precision, accuracy, limit of quantitation (LOQ), robustness, stability, and applied in bioavailability studies of our developed gastroretentive formulation in healthy volunteers. RESULTS: The calibration curves were linear over the concentration range 0.025–4 μg/ml with the detection limit of 15 ng/ml. Accuracy % were within 93–115 and the coefficient of variance % ranged from 0.20 to 12.8. The very low LOQ (25 ng/ml) allowed avoiding fluorometric detection which is more expensive and is not available in all laboratories. Ciprofloxacin was stable in samples with no evidence of degradation during 3 freeze-thaw cycles and 3 months storage at –70°C. CONCLUSION: This validated HPLC method was successfully used for the determination of ciprofloxacin in human plasma following oral administration of controlled release formulation, conventional immediate-release tablets and when administered concomitantly with divalent and trivalent cations such as aluminum-, magnesium-, or calcium-containing products under which the bioavailability of ciprofloxacin is significantly reduced.
format Online
Article
Text
id pubmed-5137234
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-51372342016-12-19 A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations Emami, Jaber Rezazadeh, Mahboubeh Adv Biomed Res Original Article BACKGROUND: A very simple, sensitive, and accurate high-performance liquid chromatography (HPLC) method with ultraviolet detector was developed and applied to determine ciprofloxacin in human plasma following administration of a gastroretentive formulation developed in our laboratory. MATERIALS AND METHODS: HPLC analysis was performed on a C(18) μ-Bondapack column (250 mm × 3.9 mm) using acetonitrile: potassium dihydrogen phosphate solution 0.1 M (20:80, v/v, pH 3) at a flow rate of 1.5 ml/min and eluate was monitored at 276 nm. After addition of phenacetin as internal standard, plasma samples were treated with 0.1 M phosphate buffer (pH: 7) and followed by extraction with dichloromethane. The method was validated for linearity, precision, accuracy, limit of quantitation (LOQ), robustness, stability, and applied in bioavailability studies of our developed gastroretentive formulation in healthy volunteers. RESULTS: The calibration curves were linear over the concentration range 0.025–4 μg/ml with the detection limit of 15 ng/ml. Accuracy % were within 93–115 and the coefficient of variance % ranged from 0.20 to 12.8. The very low LOQ (25 ng/ml) allowed avoiding fluorometric detection which is more expensive and is not available in all laboratories. Ciprofloxacin was stable in samples with no evidence of degradation during 3 freeze-thaw cycles and 3 months storage at –70°C. CONCLUSION: This validated HPLC method was successfully used for the determination of ciprofloxacin in human plasma following oral administration of controlled release formulation, conventional immediate-release tablets and when administered concomitantly with divalent and trivalent cations such as aluminum-, magnesium-, or calcium-containing products under which the bioavailability of ciprofloxacin is significantly reduced. Medknow Publications & Media Pvt Ltd 2016-10-26 /pmc/articles/PMC5137234/ /pubmed/27995102 http://dx.doi.org/10.4103/2277-9175.190995 Text en Copyright: © 2016 Advanced Biomedical Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Emami, Jaber
Rezazadeh, Mahboubeh
A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations
title A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations
title_full A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations
title_fullStr A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations
title_full_unstemmed A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations
title_short A simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations
title_sort simple and sensitive high-performance liquid chromatography method for determination of ciprofloxacin in bioavailability studies of conventional and gastroretentive prolonged-release formulations
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137234/
https://www.ncbi.nlm.nih.gov/pubmed/27995102
http://dx.doi.org/10.4103/2277-9175.190995
work_keys_str_mv AT emamijaber asimpleandsensitivehighperformanceliquidchromatographymethodfordeterminationofciprofloxacininbioavailabilitystudiesofconventionalandgastroretentiveprolongedreleaseformulations
AT rezazadehmahboubeh asimpleandsensitivehighperformanceliquidchromatographymethodfordeterminationofciprofloxacininbioavailabilitystudiesofconventionalandgastroretentiveprolongedreleaseformulations
AT emamijaber simpleandsensitivehighperformanceliquidchromatographymethodfordeterminationofciprofloxacininbioavailabilitystudiesofconventionalandgastroretentiveprolongedreleaseformulations
AT rezazadehmahboubeh simpleandsensitivehighperformanceliquidchromatographymethodfordeterminationofciprofloxacininbioavailabilitystudiesofconventionalandgastroretentiveprolongedreleaseformulations