Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation

CONTEXT: Respiratory complications, attributed to the build-up of secretions in the airway, are a leading cause of rehospitalisation for the tetraplegic population. Previously, we observed that the application of Abdominal Functional Electrical Stimulation (AFES) improved cough function and increase...

Descripción completa

Detalles Bibliográficos
Autores principales: McCaughey, Euan J., McLean, Alan N., Allan, David B., Gollee, Henrik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137572/
https://www.ncbi.nlm.nih.gov/pubmed/26689243
http://dx.doi.org/10.1080/10790268.2015.1114226
_version_ 1782471939582853120
author McCaughey, Euan J.
McLean, Alan N.
Allan, David B.
Gollee, Henrik
author_facet McCaughey, Euan J.
McLean, Alan N.
Allan, David B.
Gollee, Henrik
author_sort McCaughey, Euan J.
collection PubMed
description CONTEXT: Respiratory complications, attributed to the build-up of secretions in the airway, are a leading cause of rehospitalisation for the tetraplegic population. Previously, we observed that the application of Abdominal Functional Electrical Stimulation (AFES) improved cough function and increased demand for secretion removal, suggesting AFES may aid secretion clearance. Clinically, secretion clearance is commonly achieved by using Mechanical insufflation-exsufflation (MI-E) to simulate a cough. In this study the feasibility of combining AFES with MI-E is evaluated. FINDINGS: AFES was successfully combined with MI-E at eight fortnightly assessment sessions conducted with one sub-acute participant with tetraplegia. By using the signal from a pressure sensor, integrated with the MI-E device, AFES was correctly applied in synchrony with MI-E with an accuracy of 96.7%. Acute increases in exhaled volume and peak flow were observed during AFES assisted MI-E, compared to MI-E alone, at six of eight assessment sessions. CONCLUSION: The successful integration of AFES with MI-E at eight assessment sessions demonstrates the feasibility of this technique. The acute increases in respiratory function observed at the majority of assessment sessions generate the hypothesis that AFES assisted MI-E may be more effective for secretion clearance than MI-E alone.
format Online
Article
Text
id pubmed-5137572
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-51375722017-11-01 Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation McCaughey, Euan J. McLean, Alan N. Allan, David B. Gollee, Henrik J Spinal Cord Med Case Reports CONTEXT: Respiratory complications, attributed to the build-up of secretions in the airway, are a leading cause of rehospitalisation for the tetraplegic population. Previously, we observed that the application of Abdominal Functional Electrical Stimulation (AFES) improved cough function and increased demand for secretion removal, suggesting AFES may aid secretion clearance. Clinically, secretion clearance is commonly achieved by using Mechanical insufflation-exsufflation (MI-E) to simulate a cough. In this study the feasibility of combining AFES with MI-E is evaluated. FINDINGS: AFES was successfully combined with MI-E at eight fortnightly assessment sessions conducted with one sub-acute participant with tetraplegia. By using the signal from a pressure sensor, integrated with the MI-E device, AFES was correctly applied in synchrony with MI-E with an accuracy of 96.7%. Acute increases in exhaled volume and peak flow were observed during AFES assisted MI-E, compared to MI-E alone, at six of eight assessment sessions. CONCLUSION: The successful integration of AFES with MI-E at eight assessment sessions demonstrates the feasibility of this technique. The acute increases in respiratory function observed at the majority of assessment sessions generate the hypothesis that AFES assisted MI-E may be more effective for secretion clearance than MI-E alone. Taylor & Francis 2016-11 /pmc/articles/PMC5137572/ /pubmed/26689243 http://dx.doi.org/10.1080/10790268.2015.1114226 Text en © The Author(s). Published by Taylor & Francis. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Reports
McCaughey, Euan J.
McLean, Alan N.
Allan, David B.
Gollee, Henrik
Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
title Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
title_full Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
title_fullStr Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
title_full_unstemmed Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
title_short Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
title_sort abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137572/
https://www.ncbi.nlm.nih.gov/pubmed/26689243
http://dx.doi.org/10.1080/10790268.2015.1114226
work_keys_str_mv AT mccaugheyeuanj abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation
AT mcleanalann abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation
AT allandavidb abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation
AT golleehenrik abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation