Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation
CONTEXT: Respiratory complications, attributed to the build-up of secretions in the airway, are a leading cause of rehospitalisation for the tetraplegic population. Previously, we observed that the application of Abdominal Functional Electrical Stimulation (AFES) improved cough function and increase...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137572/ https://www.ncbi.nlm.nih.gov/pubmed/26689243 http://dx.doi.org/10.1080/10790268.2015.1114226 |
_version_ | 1782471939582853120 |
---|---|
author | McCaughey, Euan J. McLean, Alan N. Allan, David B. Gollee, Henrik |
author_facet | McCaughey, Euan J. McLean, Alan N. Allan, David B. Gollee, Henrik |
author_sort | McCaughey, Euan J. |
collection | PubMed |
description | CONTEXT: Respiratory complications, attributed to the build-up of secretions in the airway, are a leading cause of rehospitalisation for the tetraplegic population. Previously, we observed that the application of Abdominal Functional Electrical Stimulation (AFES) improved cough function and increased demand for secretion removal, suggesting AFES may aid secretion clearance. Clinically, secretion clearance is commonly achieved by using Mechanical insufflation-exsufflation (MI-E) to simulate a cough. In this study the feasibility of combining AFES with MI-E is evaluated. FINDINGS: AFES was successfully combined with MI-E at eight fortnightly assessment sessions conducted with one sub-acute participant with tetraplegia. By using the signal from a pressure sensor, integrated with the MI-E device, AFES was correctly applied in synchrony with MI-E with an accuracy of 96.7%. Acute increases in exhaled volume and peak flow were observed during AFES assisted MI-E, compared to MI-E alone, at six of eight assessment sessions. CONCLUSION: The successful integration of AFES with MI-E at eight assessment sessions demonstrates the feasibility of this technique. The acute increases in respiratory function observed at the majority of assessment sessions generate the hypothesis that AFES assisted MI-E may be more effective for secretion clearance than MI-E alone. |
format | Online Article Text |
id | pubmed-5137572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-51375722017-11-01 Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation McCaughey, Euan J. McLean, Alan N. Allan, David B. Gollee, Henrik J Spinal Cord Med Case Reports CONTEXT: Respiratory complications, attributed to the build-up of secretions in the airway, are a leading cause of rehospitalisation for the tetraplegic population. Previously, we observed that the application of Abdominal Functional Electrical Stimulation (AFES) improved cough function and increased demand for secretion removal, suggesting AFES may aid secretion clearance. Clinically, secretion clearance is commonly achieved by using Mechanical insufflation-exsufflation (MI-E) to simulate a cough. In this study the feasibility of combining AFES with MI-E is evaluated. FINDINGS: AFES was successfully combined with MI-E at eight fortnightly assessment sessions conducted with one sub-acute participant with tetraplegia. By using the signal from a pressure sensor, integrated with the MI-E device, AFES was correctly applied in synchrony with MI-E with an accuracy of 96.7%. Acute increases in exhaled volume and peak flow were observed during AFES assisted MI-E, compared to MI-E alone, at six of eight assessment sessions. CONCLUSION: The successful integration of AFES with MI-E at eight assessment sessions demonstrates the feasibility of this technique. The acute increases in respiratory function observed at the majority of assessment sessions generate the hypothesis that AFES assisted MI-E may be more effective for secretion clearance than MI-E alone. Taylor & Francis 2016-11 /pmc/articles/PMC5137572/ /pubmed/26689243 http://dx.doi.org/10.1080/10790268.2015.1114226 Text en © The Author(s). Published by Taylor & Francis. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Reports McCaughey, Euan J. McLean, Alan N. Allan, David B. Gollee, Henrik Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation |
title | Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation |
title_full | Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation |
title_fullStr | Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation |
title_full_unstemmed | Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation |
title_short | Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation |
title_sort | abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5137572/ https://www.ncbi.nlm.nih.gov/pubmed/26689243 http://dx.doi.org/10.1080/10790268.2015.1114226 |
work_keys_str_mv | AT mccaugheyeuanj abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation AT mcleanalann abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation AT allandavidb abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation AT golleehenrik abdominalfunctionalelectricalstimulationtoenhancemechanicalinsufflationexsufflation |