Cargando…

Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?

Although intracranial pressure (ICP) is essential to guide management of patients suffering from acute brain diseases, this signal is often neglected outside the neurocritical care environment. This is mainly attributed to the intrinsic risks of the available invasive techniques, which have prevente...

Descripción completa

Detalles Bibliográficos
Autores principales: Cardim, Danilo, Robba, C., Bohdanowicz, M., Donnelly, J., Cabella, B., Liu, X., Cabeleira, M., Smielewski, P., Schmidt, B., Czosnyka, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5138275/
https://www.ncbi.nlm.nih.gov/pubmed/26940914
http://dx.doi.org/10.1007/s12028-016-0258-6
_version_ 1782472037860638720
author Cardim, Danilo
Robba, C.
Bohdanowicz, M.
Donnelly, J.
Cabella, B.
Liu, X.
Cabeleira, M.
Smielewski, P.
Schmidt, B.
Czosnyka, M.
author_facet Cardim, Danilo
Robba, C.
Bohdanowicz, M.
Donnelly, J.
Cabella, B.
Liu, X.
Cabeleira, M.
Smielewski, P.
Schmidt, B.
Czosnyka, M.
author_sort Cardim, Danilo
collection PubMed
description Although intracranial pressure (ICP) is essential to guide management of patients suffering from acute brain diseases, this signal is often neglected outside the neurocritical care environment. This is mainly attributed to the intrinsic risks of the available invasive techniques, which have prevented ICP monitoring in many conditions affecting the intracranial homeostasis, from mild traumatic brain injury to liver encephalopathy. In such scenario, methods for non-invasive monitoring of ICP (nICP) could improve clinical management of these conditions. A review of the literature was performed on PUBMED using the search keywords ‘Transcranial Doppler non-invasive intracranial pressure.’ Transcranial Doppler (TCD) is a technique primarily aimed at assessing the cerebrovascular dynamics through the cerebral blood flow velocity (FV). Its applicability for nICP assessment emerged from observation that some TCD-derived parameters change during increase of ICP, such as the shape of FV pulse waveform or pulsatility index. Methods were grouped as: based on TCD pulsatility index; aimed at non-invasive estimation of cerebral perfusion pressure and model-based methods. Published studies present with different accuracies, with prediction abilities (AUCs) for detection of ICP ≥20 mmHg ranging from 0.62 to 0.92. This discrepancy could result from inconsistent assessment measures and application in different conditions, from traumatic brain injury to hydrocephalus and stroke. Most of the reports stress a potential advantage of TCD as it provides the possibility to monitor changes of ICP in time. Overall accuracy for TCD-based methods ranges around ±12 mmHg, with a great potential of tracing dynamical changes of ICP in time, particularly those of vasogenic nature.
format Online
Article
Text
id pubmed-5138275
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-51382752016-12-21 Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible? Cardim, Danilo Robba, C. Bohdanowicz, M. Donnelly, J. Cabella, B. Liu, X. Cabeleira, M. Smielewski, P. Schmidt, B. Czosnyka, M. Neurocrit Care Review Article Although intracranial pressure (ICP) is essential to guide management of patients suffering from acute brain diseases, this signal is often neglected outside the neurocritical care environment. This is mainly attributed to the intrinsic risks of the available invasive techniques, which have prevented ICP monitoring in many conditions affecting the intracranial homeostasis, from mild traumatic brain injury to liver encephalopathy. In such scenario, methods for non-invasive monitoring of ICP (nICP) could improve clinical management of these conditions. A review of the literature was performed on PUBMED using the search keywords ‘Transcranial Doppler non-invasive intracranial pressure.’ Transcranial Doppler (TCD) is a technique primarily aimed at assessing the cerebrovascular dynamics through the cerebral blood flow velocity (FV). Its applicability for nICP assessment emerged from observation that some TCD-derived parameters change during increase of ICP, such as the shape of FV pulse waveform or pulsatility index. Methods were grouped as: based on TCD pulsatility index; aimed at non-invasive estimation of cerebral perfusion pressure and model-based methods. Published studies present with different accuracies, with prediction abilities (AUCs) for detection of ICP ≥20 mmHg ranging from 0.62 to 0.92. This discrepancy could result from inconsistent assessment measures and application in different conditions, from traumatic brain injury to hydrocephalus and stroke. Most of the reports stress a potential advantage of TCD as it provides the possibility to monitor changes of ICP in time. Overall accuracy for TCD-based methods ranges around ±12 mmHg, with a great potential of tracing dynamical changes of ICP in time, particularly those of vasogenic nature. Springer US 2016-03-03 2016 /pmc/articles/PMC5138275/ /pubmed/26940914 http://dx.doi.org/10.1007/s12028-016-0258-6 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review Article
Cardim, Danilo
Robba, C.
Bohdanowicz, M.
Donnelly, J.
Cabella, B.
Liu, X.
Cabeleira, M.
Smielewski, P.
Schmidt, B.
Czosnyka, M.
Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
title Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
title_full Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
title_fullStr Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
title_full_unstemmed Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
title_short Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
title_sort non-invasive monitoring of intracranial pressure using transcranial doppler ultrasonography: is it possible?
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5138275/
https://www.ncbi.nlm.nih.gov/pubmed/26940914
http://dx.doi.org/10.1007/s12028-016-0258-6
work_keys_str_mv AT cardimdanilo noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT robbac noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT bohdanowiczm noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT donnellyj noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT cabellab noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT liux noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT cabeleiram noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT smielewskip noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT schmidtb noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible
AT czosnykam noninvasivemonitoringofintracranialpressureusingtranscranialdopplerultrasonographyisitpossible