Cargando…
Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital
PURPOSE: The purpose of this study is to evaluate the causes of phakic implantable collamer lens (ICL) explantation/exchange at an eye hospital in Saudi Arabia. MATERIALS AND METHODS: A retrospective chart review was performed for patients who underwent ICL implantation from 2007 to March 2014 and d...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5141621/ https://www.ncbi.nlm.nih.gov/pubmed/27994391 http://dx.doi.org/10.4103/0974-9233.194076 |
_version_ | 1782472647305592832 |
---|---|
author | AlSabaani, Nasser A. Behrens, Ashley Jastanieah, Sabah Al Malki, Salem Al Jindan, Mohanna Al Motowa, Saeed |
author_facet | AlSabaani, Nasser A. Behrens, Ashley Jastanieah, Sabah Al Malki, Salem Al Jindan, Mohanna Al Motowa, Saeed |
author_sort | AlSabaani, Nasser A. |
collection | PubMed |
description | PURPOSE: The purpose of this study is to evaluate the causes of phakic implantable collamer lens (ICL) explantation/exchange at an eye hospital in Saudi Arabia. MATERIALS AND METHODS: A retrospective chart review was performed for patients who underwent ICL implantation from 2007 to March 2014 and data were collected on cases that underwent ICL explantation. RESULTS: Of the 787 ICL implants, 30 implants (3.8% [95% confidence interval 2.6%; 5.3%]) were explanted. The causes of explantation included incorrect lens size (22), cataract (4), high residual astigmatism (2), rhegmatogenous retinal detachment (1), and intolerable glare (1). Corrective measures mainly included an exchange with an appropriately sized lens (9), ICL explantation (11), with phacoemulsification and posterior chamber intraocular lens implantation (6), or replacement with an ICL of correct power (2). CONCLUSION: Incorrect ICL size was the most common cause of ICL explantation. More accurate sizing methods for ICL are required to reduce the explantation/exchange rate. |
format | Online Article Text |
id | pubmed-5141621 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-51416212016-12-19 Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital AlSabaani, Nasser A. Behrens, Ashley Jastanieah, Sabah Al Malki, Salem Al Jindan, Mohanna Al Motowa, Saeed Middle East Afr J Ophthalmol Original Article PURPOSE: The purpose of this study is to evaluate the causes of phakic implantable collamer lens (ICL) explantation/exchange at an eye hospital in Saudi Arabia. MATERIALS AND METHODS: A retrospective chart review was performed for patients who underwent ICL implantation from 2007 to March 2014 and data were collected on cases that underwent ICL explantation. RESULTS: Of the 787 ICL implants, 30 implants (3.8% [95% confidence interval 2.6%; 5.3%]) were explanted. The causes of explantation included incorrect lens size (22), cataract (4), high residual astigmatism (2), rhegmatogenous retinal detachment (1), and intolerable glare (1). Corrective measures mainly included an exchange with an appropriately sized lens (9), ICL explantation (11), with phacoemulsification and posterior chamber intraocular lens implantation (6), or replacement with an ICL of correct power (2). CONCLUSION: Incorrect ICL size was the most common cause of ICL explantation. More accurate sizing methods for ICL are required to reduce the explantation/exchange rate. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5141621/ /pubmed/27994391 http://dx.doi.org/10.4103/0974-9233.194076 Text en Copyright: © Middle East African Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article AlSabaani, Nasser A. Behrens, Ashley Jastanieah, Sabah Al Malki, Salem Al Jindan, Mohanna Al Motowa, Saeed Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital |
title | Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital |
title_full | Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital |
title_fullStr | Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital |
title_full_unstemmed | Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital |
title_short | Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital |
title_sort | causes of phakic implantable collamer lens explantation/exchange at king khaled eye specialist hospital |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5141621/ https://www.ncbi.nlm.nih.gov/pubmed/27994391 http://dx.doi.org/10.4103/0974-9233.194076 |
work_keys_str_mv | AT alsabaaninassera causesofphakicimplantablecollamerlensexplantationexchangeatkingkhaledeyespecialisthospital AT behrensashley causesofphakicimplantablecollamerlensexplantationexchangeatkingkhaledeyespecialisthospital AT jastanieahsabah causesofphakicimplantablecollamerlensexplantationexchangeatkingkhaledeyespecialisthospital AT almalkisalem causesofphakicimplantablecollamerlensexplantationexchangeatkingkhaledeyespecialisthospital AT aljindanmohanna causesofphakicimplantablecollamerlensexplantationexchangeatkingkhaledeyespecialisthospital AT almotowasaeed causesofphakicimplantablecollamerlensexplantationexchangeatkingkhaledeyespecialisthospital |