Cargando…
A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5143701/ https://www.ncbi.nlm.nih.gov/pubmed/27999808 http://dx.doi.org/10.1155/2016/6596040 |
_version_ | 1782472980492713984 |
---|---|
author | Ruiz de Gauna, Sofía González-Otero, Digna M. Ruiz, Jesus Gutiérrez, J. J. Russell, James K. |
author_facet | Ruiz de Gauna, Sofía González-Otero, Digna M. Ruiz, Jesus Gutiérrez, J. J. Russell, James K. |
author_sort | Ruiz de Gauna, Sofía |
collection | PubMed |
description | Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin's back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%). Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p < 0.001). Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p < 0.001). Median error in rate was 0.9 cpm (1.0%), with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces. |
format | Online Article Text |
id | pubmed-5143701 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-51437012016-12-20 A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis Ruiz de Gauna, Sofía González-Otero, Digna M. Ruiz, Jesus Gutiérrez, J. J. Russell, James K. Biomed Res Int Research Article Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin's back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%). Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p < 0.001). Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p < 0.001). Median error in rate was 0.9 cpm (1.0%), with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces. Hindawi Publishing Corporation 2016 2016-11-24 /pmc/articles/PMC5143701/ /pubmed/27999808 http://dx.doi.org/10.1155/2016/6596040 Text en Copyright © 2016 Sofía Ruiz de Gauna et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ruiz de Gauna, Sofía González-Otero, Digna M. Ruiz, Jesus Gutiérrez, J. J. Russell, James K. A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis |
title | A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis |
title_full | A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis |
title_fullStr | A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis |
title_full_unstemmed | A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis |
title_short | A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis |
title_sort | feasibility study for measuring accurate chest compression depth and rate on soft surfaces using two accelerometers and spectral analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5143701/ https://www.ncbi.nlm.nih.gov/pubmed/27999808 http://dx.doi.org/10.1155/2016/6596040 |
work_keys_str_mv | AT ruizdegaunasofia afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT gonzalezoterodignam afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT ruizjesus afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT gutierrezjj afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT russelljamesk afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT ruizdegaunasofia feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT gonzalezoterodignam feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT ruizjesus feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT gutierrezjj feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis AT russelljamesk feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis |