Cargando…

A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis

Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruiz de Gauna, Sofía, González-Otero, Digna M., Ruiz, Jesus, Gutiérrez, J. J., Russell, James K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5143701/
https://www.ncbi.nlm.nih.gov/pubmed/27999808
http://dx.doi.org/10.1155/2016/6596040
_version_ 1782472980492713984
author Ruiz de Gauna, Sofía
González-Otero, Digna M.
Ruiz, Jesus
Gutiérrez, J. J.
Russell, James K.
author_facet Ruiz de Gauna, Sofía
González-Otero, Digna M.
Ruiz, Jesus
Gutiérrez, J. J.
Russell, James K.
author_sort Ruiz de Gauna, Sofía
collection PubMed
description Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin's back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%). Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p < 0.001). Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p < 0.001). Median error in rate was 0.9 cpm (1.0%), with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces.
format Online
Article
Text
id pubmed-5143701
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-51437012016-12-20 A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis Ruiz de Gauna, Sofía González-Otero, Digna M. Ruiz, Jesus Gutiérrez, J. J. Russell, James K. Biomed Res Int Research Article Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin's back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%). Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p < 0.001). Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p < 0.001). Median error in rate was 0.9 cpm (1.0%), with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces. Hindawi Publishing Corporation 2016 2016-11-24 /pmc/articles/PMC5143701/ /pubmed/27999808 http://dx.doi.org/10.1155/2016/6596040 Text en Copyright © 2016 Sofía Ruiz de Gauna et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ruiz de Gauna, Sofía
González-Otero, Digna M.
Ruiz, Jesus
Gutiérrez, J. J.
Russell, James K.
A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
title A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
title_full A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
title_fullStr A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
title_full_unstemmed A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
title_short A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
title_sort feasibility study for measuring accurate chest compression depth and rate on soft surfaces using two accelerometers and spectral analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5143701/
https://www.ncbi.nlm.nih.gov/pubmed/27999808
http://dx.doi.org/10.1155/2016/6596040
work_keys_str_mv AT ruizdegaunasofia afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT gonzalezoterodignam afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT ruizjesus afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT gutierrezjj afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT russelljamesk afeasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT ruizdegaunasofia feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT gonzalezoterodignam feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT ruizjesus feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT gutierrezjj feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis
AT russelljamesk feasibilitystudyformeasuringaccuratechestcompressiondepthandrateonsoftsurfacesusingtwoaccelerometersandspectralanalysis