Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy

BACKGROUND AND AIMS: There have been variable results on the practice of tight glycemic control, and studies have demonstrated that point-of-care (POC) glucometers have variable accuracy. Glucometers must be accurate, and many variables can affect blood glucose levels. The purpose of this study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahmoodpoor, Ata, Hamishehkar, Hadi, Shadvar, Kamran, Sanaie, Sarvin, Iranpour, Afshin, Fattahi, Vahid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5144527/
https://www.ncbi.nlm.nih.gov/pubmed/27994380
http://dx.doi.org/10.4103/0972-5229.194009
_version_ 1782473142880436224
author Mahmoodpoor, Ata
Hamishehkar, Hadi
Shadvar, Kamran
Sanaie, Sarvin
Iranpour, Afshin
Fattahi, Vahid
author_facet Mahmoodpoor, Ata
Hamishehkar, Hadi
Shadvar, Kamran
Sanaie, Sarvin
Iranpour, Afshin
Fattahi, Vahid
author_sort Mahmoodpoor, Ata
collection PubMed
description BACKGROUND AND AIMS: There have been variable results on the practice of tight glycemic control, and studies have demonstrated that point-of-care (POC) glucometers have variable accuracy. Glucometers must be accurate, and many variables can affect blood glucose levels. The purpose of this study was to determine the difference between blood glucose concentrations obtained from POC glucometers and laboratory results in critically ill patients with intensive insulin therapy. MATERIALS AND METHODS: This was a descriptive study which enrolled 300 critically ill patients. Four samples of arterial blood were collected and analyzed at the bedside with the POC glucometer and also in the central laboratory to obtain the blood glucose level. To define the effect of various factors on this relation, we noted the levels of hemoglobin (Hb), PaO(2), body temperature, bilirubin, history of drug usage, and sepsis. RESULTS: There were not any significant differences between blood sugar levels using laboratory and glucometer methods of measurements. There was a good and significant correlation between glucose levels between two methods (r = 0.81, P < 0.001). Among evaluated factors (body temperature, bilirubin level, blood pressure, Hb level, PaO(2), sepsis, and drugs) which added one by one in model, just drugs decreased the correlation more than others (r = 0.78). CONCLUSIONS: The results of POC glucometer differ from laboratory glucose concentrations, especially in critically ill patients with unstable hemodynamic status while receiving several drugs. This may raise the concern about using POC devices for tight glycemic control in critically ill patients. These results should be interpreted with caution because of the large variation of accuracy among different glucometer devices.
format Online
Article
Text
id pubmed-5144527
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-51445272016-12-19 Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy Mahmoodpoor, Ata Hamishehkar, Hadi Shadvar, Kamran Sanaie, Sarvin Iranpour, Afshin Fattahi, Vahid Indian J Crit Care Med Research Article BACKGROUND AND AIMS: There have been variable results on the practice of tight glycemic control, and studies have demonstrated that point-of-care (POC) glucometers have variable accuracy. Glucometers must be accurate, and many variables can affect blood glucose levels. The purpose of this study was to determine the difference between blood glucose concentrations obtained from POC glucometers and laboratory results in critically ill patients with intensive insulin therapy. MATERIALS AND METHODS: This was a descriptive study which enrolled 300 critically ill patients. Four samples of arterial blood were collected and analyzed at the bedside with the POC glucometer and also in the central laboratory to obtain the blood glucose level. To define the effect of various factors on this relation, we noted the levels of hemoglobin (Hb), PaO(2), body temperature, bilirubin, history of drug usage, and sepsis. RESULTS: There were not any significant differences between blood sugar levels using laboratory and glucometer methods of measurements. There was a good and significant correlation between glucose levels between two methods (r = 0.81, P < 0.001). Among evaluated factors (body temperature, bilirubin level, blood pressure, Hb level, PaO(2), sepsis, and drugs) which added one by one in model, just drugs decreased the correlation more than others (r = 0.78). CONCLUSIONS: The results of POC glucometer differ from laboratory glucose concentrations, especially in critically ill patients with unstable hemodynamic status while receiving several drugs. This may raise the concern about using POC devices for tight glycemic control in critically ill patients. These results should be interpreted with caution because of the large variation of accuracy among different glucometer devices. Medknow Publications & Media Pvt Ltd 2016-11 /pmc/articles/PMC5144527/ /pubmed/27994380 http://dx.doi.org/10.4103/0972-5229.194009 Text en Copyright: © Indian Journal of Critical Care Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Research Article
Mahmoodpoor, Ata
Hamishehkar, Hadi
Shadvar, Kamran
Sanaie, Sarvin
Iranpour, Afshin
Fattahi, Vahid
Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy
title Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy
title_full Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy
title_fullStr Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy
title_full_unstemmed Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy
title_short Validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy
title_sort validity of bedside blood glucose measurement in critically ill patients with intensive insulin therapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5144527/
https://www.ncbi.nlm.nih.gov/pubmed/27994380
http://dx.doi.org/10.4103/0972-5229.194009
work_keys_str_mv AT mahmoodpoorata validityofbedsidebloodglucosemeasurementincriticallyillpatientswithintensiveinsulintherapy
AT hamishehkarhadi validityofbedsidebloodglucosemeasurementincriticallyillpatientswithintensiveinsulintherapy
AT shadvarkamran validityofbedsidebloodglucosemeasurementincriticallyillpatientswithintensiveinsulintherapy
AT sanaiesarvin validityofbedsidebloodglucosemeasurementincriticallyillpatientswithintensiveinsulintherapy
AT iranpourafshin validityofbedsidebloodglucosemeasurementincriticallyillpatientswithintensiveinsulintherapy
AT fattahivahid validityofbedsidebloodglucosemeasurementincriticallyillpatientswithintensiveinsulintherapy