Cargando…

Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography

BACKGROUND The cause of common bile duct (CBD) dilatation cannot be determined by imaging modalities in many patients. The aim of this study was to assess the value of endoscopic ultrasonography (EUS) in detecting the cause of CBD dilatation in patients in whom ultrasonography could not demonstrate...

Descripción completa

Detalles Bibliográficos
Autores principales: Sotoudehmanesh, Rasoul, Nejati, Naimeh, Farsinejad, Maryam, Kolahdoozan, Shadi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iranian Association of Gastroerterology and Hepatology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5145293/
https://www.ncbi.nlm.nih.gov/pubmed/27957289
http://dx.doi.org/10.15171/mejdd.2016.35
_version_ 1782473268209385472
author Sotoudehmanesh, Rasoul
Nejati, Naimeh
Farsinejad, Maryam
Kolahdoozan, Shadi
author_facet Sotoudehmanesh, Rasoul
Nejati, Naimeh
Farsinejad, Maryam
Kolahdoozan, Shadi
author_sort Sotoudehmanesh, Rasoul
collection PubMed
description BACKGROUND The cause of common bile duct (CBD) dilatation cannot be determined by imaging modalities in many patients. The aim of this study was to assess the value of endoscopic ultrasonography (EUS) in detecting the cause of CBD dilatation in patients in whom ultrasonography could not demonstrate the cause of dilation. METHODS Prospectively, 152 consecutive patients who were referred for evaluation of dilated CBD (diameter ≥7 mm) of undetermined origin by ultrasonography were included in this study. All the patients underwent EUS. Final diagnoses were determined by using endoscopic retrograde cholangiopancreatography (ERCP), EUS-guided fine needle aspiration (FNA), surgical exploration, or follow-up for at least 10 months. Patients with choledocholithiasis were referred for ERCP and sphincterotomy, and patients with operable tumors were referred for surgery.Patients with inoperable tumors underwent biliary stenting with or without tchemoradiotherapy. RESULTS 152 patients (54% female) with dilated CBD were included. Mean (±SD) age of the patients was 60.4 (±17.3) years. The mean CBD diameter for all study group in transabdominal ultrasonography and EUS were 11.7 millimeter and 10.1 millimeter, respectively. Most of the patients with dilated CBD and abnormal liver function test (LFT) had an important finding in EUS and follow-up diagnosis including peri-ampullary tumors. Mean diameter of CBD in patients with and without abnormal LFT were 10.5 IU/L and 12.1 IU/L, respectively. Final diagnoses included choledocholithiasis in 32 (21.1%),passed CBD stone in 35 (23%), opium-induced CBD dilation in 14 (9.2%), post-cholecystectomy states in 20 (13.1%), ampullary adenoma/carcinoma in 15 (15.8%), cholangiocarcinoma in 14 (9.2%), and pancreatic head cancer in9 (5.9%) patients. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of EUS for patients with abnormal EUS were 89.5%, 100.0%, 100.0%, 91.2%, and 90.9%, respectively. CONCLUSION After diagnosis of CBD dilation by transabdominal ultrasonography, EUS may be a reasonable choice for determining the etiology of dilated CBD and tumor staging.
format Online
Article
Text
id pubmed-5145293
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Iranian Association of Gastroerterology and Hepatology
record_format MEDLINE/PubMed
spelling pubmed-51452932016-12-12 Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography Sotoudehmanesh, Rasoul Nejati, Naimeh Farsinejad, Maryam Kolahdoozan, Shadi Middle East J Dig Dis Original Article BACKGROUND The cause of common bile duct (CBD) dilatation cannot be determined by imaging modalities in many patients. The aim of this study was to assess the value of endoscopic ultrasonography (EUS) in detecting the cause of CBD dilatation in patients in whom ultrasonography could not demonstrate the cause of dilation. METHODS Prospectively, 152 consecutive patients who were referred for evaluation of dilated CBD (diameter ≥7 mm) of undetermined origin by ultrasonography were included in this study. All the patients underwent EUS. Final diagnoses were determined by using endoscopic retrograde cholangiopancreatography (ERCP), EUS-guided fine needle aspiration (FNA), surgical exploration, or follow-up for at least 10 months. Patients with choledocholithiasis were referred for ERCP and sphincterotomy, and patients with operable tumors were referred for surgery.Patients with inoperable tumors underwent biliary stenting with or without tchemoradiotherapy. RESULTS 152 patients (54% female) with dilated CBD were included. Mean (±SD) age of the patients was 60.4 (±17.3) years. The mean CBD diameter for all study group in transabdominal ultrasonography and EUS were 11.7 millimeter and 10.1 millimeter, respectively. Most of the patients with dilated CBD and abnormal liver function test (LFT) had an important finding in EUS and follow-up diagnosis including peri-ampullary tumors. Mean diameter of CBD in patients with and without abnormal LFT were 10.5 IU/L and 12.1 IU/L, respectively. Final diagnoses included choledocholithiasis in 32 (21.1%),passed CBD stone in 35 (23%), opium-induced CBD dilation in 14 (9.2%), post-cholecystectomy states in 20 (13.1%), ampullary adenoma/carcinoma in 15 (15.8%), cholangiocarcinoma in 14 (9.2%), and pancreatic head cancer in9 (5.9%) patients. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of EUS for patients with abnormal EUS were 89.5%, 100.0%, 100.0%, 91.2%, and 90.9%, respectively. CONCLUSION After diagnosis of CBD dilation by transabdominal ultrasonography, EUS may be a reasonable choice for determining the etiology of dilated CBD and tumor staging. Iranian Association of Gastroerterology and Hepatology 2016-10 /pmc/articles/PMC5145293/ /pubmed/27957289 http://dx.doi.org/10.15171/mejdd.2016.35 Text en © 2016 by Middle East Journal of Digestive Diseases This work is published by Middle East Journal of Digestive Diseases as an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc-sa/4.0/). Non-commercial uses of the work are permitted, provided the original work is properly cited.
spellingShingle Original Article
Sotoudehmanesh, Rasoul
Nejati, Naimeh
Farsinejad, Maryam
Kolahdoozan, Shadi
Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography
title Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography
title_full Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography
title_fullStr Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography
title_full_unstemmed Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography
title_short Efficacy of Endoscopic Ultrasonography in Evaluation of Undetermined Etiology of Common Bile Duct Dilatation on Abdominal Ultrasonography
title_sort efficacy of endoscopic ultrasonography in evaluation of undetermined etiology of common bile duct dilatation on abdominal ultrasonography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5145293/
https://www.ncbi.nlm.nih.gov/pubmed/27957289
http://dx.doi.org/10.15171/mejdd.2016.35
work_keys_str_mv AT sotoudehmaneshrasoul efficacyofendoscopicultrasonographyinevaluationofundeterminedetiologyofcommonbileductdilatationonabdominalultrasonography
AT nejatinaimeh efficacyofendoscopicultrasonographyinevaluationofundeterminedetiologyofcommonbileductdilatationonabdominalultrasonography
AT farsinejadmaryam efficacyofendoscopicultrasonographyinevaluationofundeterminedetiologyofcommonbileductdilatationonabdominalultrasonography
AT kolahdoozanshadi efficacyofendoscopicultrasonographyinevaluationofundeterminedetiologyofcommonbileductdilatationonabdominalultrasonography