Tissue Doppler echocardiography – A case of right tool, wrong use

BACKGROUND: The developments in echocardiography or ultrasound cardiography (UCG) have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE) is one such example?...

Descripción completa

Detalles Bibliográficos
Autor principal: Thomas, George
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC514568/
https://www.ncbi.nlm.nih.gov/pubmed/15307890
http://dx.doi.org/10.1186/1476-7120-2-12
_version_ 1782121729944977408
author Thomas, George
author_facet Thomas, George
author_sort Thomas, George
collection PubMed
description BACKGROUND: The developments in echocardiography or ultrasound cardiography (UCG) have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE) is one such example? PRESENTATION OF THE HYPOTHESIS: TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. TESTING THE HYPOTHESIS: To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. IMPLICATIONS OF THE HYPOTHESIS: As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.
format Text
id pubmed-514568
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-5145682004-08-27 Tissue Doppler echocardiography – A case of right tool, wrong use Thomas, George Cardiovasc Ultrasound Hypothesis BACKGROUND: The developments in echocardiography or ultrasound cardiography (UCG) have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE) is one such example? PRESENTATION OF THE HYPOTHESIS: TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. TESTING THE HYPOTHESIS: To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. IMPLICATIONS OF THE HYPOTHESIS: As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist. BioMed Central 2004-08-12 /pmc/articles/PMC514568/ /pubmed/15307890 http://dx.doi.org/10.1186/1476-7120-2-12 Text en Copyright © 2004 Thomas; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Hypothesis
Thomas, George
Tissue Doppler echocardiography – A case of right tool, wrong use
title Tissue Doppler echocardiography – A case of right tool, wrong use
title_full Tissue Doppler echocardiography – A case of right tool, wrong use
title_fullStr Tissue Doppler echocardiography – A case of right tool, wrong use
title_full_unstemmed Tissue Doppler echocardiography – A case of right tool, wrong use
title_short Tissue Doppler echocardiography – A case of right tool, wrong use
title_sort tissue doppler echocardiography – a case of right tool, wrong use
topic Hypothesis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC514568/
https://www.ncbi.nlm.nih.gov/pubmed/15307890
http://dx.doi.org/10.1186/1476-7120-2-12
work_keys_str_mv AT thomasgeorge tissuedopplerechocardiographyacaseofrighttoolwronguse