Cargando…
Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
AIM: The aim of this study is to assess the accuracy of images acquired with cone-beam computed tomography (CBCT) in the identification of three different root alterations. MATERIALS AND METHODS: Forty human premolars were allocated to four experimental groups (n = 10): sound teeth (control), vertic...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146776/ https://www.ncbi.nlm.nih.gov/pubmed/27994322 http://dx.doi.org/10.4103/0972-0707.194029 |
_version_ | 1782473547753455616 |
---|---|
author | Bragatto, Fernanda Paula Iwaki Filho, Liogi Kasuya, Amanda Vessoni Barbosa Chicarelli, Mariliani Queiroz, Alfredo Franco Takeshita, Wilton Mitsunari Iwaki, Lilian Cristina Vessoni |
author_facet | Bragatto, Fernanda Paula Iwaki Filho, Liogi Kasuya, Amanda Vessoni Barbosa Chicarelli, Mariliani Queiroz, Alfredo Franco Takeshita, Wilton Mitsunari Iwaki, Lilian Cristina Vessoni |
author_sort | Bragatto, Fernanda Paula |
collection | PubMed |
description | AIM: The aim of this study is to assess the accuracy of images acquired with cone-beam computed tomography (CBCT) in the identification of three different root alterations. MATERIALS AND METHODS: Forty human premolars were allocated to four experimental groups (n = 10): sound teeth (control), vertical root fracture (VRF), external root resorption (ERR), and root perforation (RP). After the root alterations had been produced, four teeth were randomly assembled into 10 macerated mandibles and submitted to CBCT. Images were acquired with five voxel sizes (0.125, 0.200, 0.250, 0.300, and 0.400 mm) and assessed by three experienced dental radiologists. Sensitivity, specificity, positive and negative predictive values, and the areas under the receiver operating characteristic curve (accuracy) were calculated. The accuracy of imaging in different voxel sizes was compared with Tukey exact binomial test (α=5%). RESULTS: Accuracy with voxel sizes 0.125, 0.200, and 0.250 mm was significantly higher in the detection of ERRs and VRFs than voxel sizes 0.300 and 0.400 mm. No statistical difference was found in terms of accuracy among any of the studied voxel sizes in the identification of RPs. CONCLUSIONS: Voxel size 0.125 mm produced images with the best resolution without increasing radiation levels to the patient when compared to voxel sizes 0.200 and 0.250 mm. Voxel sizes 0.300 and 0.400 mm should be avoided in the identification of root alterations. |
format | Online Article Text |
id | pubmed-5146776 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-51467762016-12-19 Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition Bragatto, Fernanda Paula Iwaki Filho, Liogi Kasuya, Amanda Vessoni Barbosa Chicarelli, Mariliani Queiroz, Alfredo Franco Takeshita, Wilton Mitsunari Iwaki, Lilian Cristina Vessoni J Conserv Dent Original Research Article AIM: The aim of this study is to assess the accuracy of images acquired with cone-beam computed tomography (CBCT) in the identification of three different root alterations. MATERIALS AND METHODS: Forty human premolars were allocated to four experimental groups (n = 10): sound teeth (control), vertical root fracture (VRF), external root resorption (ERR), and root perforation (RP). After the root alterations had been produced, four teeth were randomly assembled into 10 macerated mandibles and submitted to CBCT. Images were acquired with five voxel sizes (0.125, 0.200, 0.250, 0.300, and 0.400 mm) and assessed by three experienced dental radiologists. Sensitivity, specificity, positive and negative predictive values, and the areas under the receiver operating characteristic curve (accuracy) were calculated. The accuracy of imaging in different voxel sizes was compared with Tukey exact binomial test (α=5%). RESULTS: Accuracy with voxel sizes 0.125, 0.200, and 0.250 mm was significantly higher in the detection of ERRs and VRFs than voxel sizes 0.300 and 0.400 mm. No statistical difference was found in terms of accuracy among any of the studied voxel sizes in the identification of RPs. CONCLUSIONS: Voxel size 0.125 mm produced images with the best resolution without increasing radiation levels to the patient when compared to voxel sizes 0.200 and 0.250 mm. Voxel sizes 0.300 and 0.400 mm should be avoided in the identification of root alterations. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5146776/ /pubmed/27994322 http://dx.doi.org/10.4103/0972-0707.194029 Text en Copyright: © Journal of Conservative Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Research Article Bragatto, Fernanda Paula Iwaki Filho, Liogi Kasuya, Amanda Vessoni Barbosa Chicarelli, Mariliani Queiroz, Alfredo Franco Takeshita, Wilton Mitsunari Iwaki, Lilian Cristina Vessoni Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition |
title | Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition |
title_full | Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition |
title_fullStr | Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition |
title_full_unstemmed | Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition |
title_short | Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition |
title_sort | accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146776/ https://www.ncbi.nlm.nih.gov/pubmed/27994322 http://dx.doi.org/10.4103/0972-0707.194029 |
work_keys_str_mv | AT bragattofernandapaula accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition AT iwakifilholiogi accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition AT kasuyaamandavessonibarbosa accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition AT chicarellimariliani accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition AT queirozalfredofranco accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition AT takeshitawiltonmitsunari accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition AT iwakililiancristinavessoni accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition |