Cargando…

Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition

AIM: The aim of this study is to assess the accuracy of images acquired with cone-beam computed tomography (CBCT) in the identification of three different root alterations. MATERIALS AND METHODS: Forty human premolars were allocated to four experimental groups (n = 10): sound teeth (control), vertic...

Descripción completa

Detalles Bibliográficos
Autores principales: Bragatto, Fernanda Paula, Iwaki Filho, Liogi, Kasuya, Amanda Vessoni Barbosa, Chicarelli, Mariliani, Queiroz, Alfredo Franco, Takeshita, Wilton Mitsunari, Iwaki, Lilian Cristina Vessoni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146776/
https://www.ncbi.nlm.nih.gov/pubmed/27994322
http://dx.doi.org/10.4103/0972-0707.194029
_version_ 1782473547753455616
author Bragatto, Fernanda Paula
Iwaki Filho, Liogi
Kasuya, Amanda Vessoni Barbosa
Chicarelli, Mariliani
Queiroz, Alfredo Franco
Takeshita, Wilton Mitsunari
Iwaki, Lilian Cristina Vessoni
author_facet Bragatto, Fernanda Paula
Iwaki Filho, Liogi
Kasuya, Amanda Vessoni Barbosa
Chicarelli, Mariliani
Queiroz, Alfredo Franco
Takeshita, Wilton Mitsunari
Iwaki, Lilian Cristina Vessoni
author_sort Bragatto, Fernanda Paula
collection PubMed
description AIM: The aim of this study is to assess the accuracy of images acquired with cone-beam computed tomography (CBCT) in the identification of three different root alterations. MATERIALS AND METHODS: Forty human premolars were allocated to four experimental groups (n = 10): sound teeth (control), vertical root fracture (VRF), external root resorption (ERR), and root perforation (RP). After the root alterations had been produced, four teeth were randomly assembled into 10 macerated mandibles and submitted to CBCT. Images were acquired with five voxel sizes (0.125, 0.200, 0.250, 0.300, and 0.400 mm) and assessed by three experienced dental radiologists. Sensitivity, specificity, positive and negative predictive values, and the areas under the receiver operating characteristic curve (accuracy) were calculated. The accuracy of imaging in different voxel sizes was compared with Tukey exact binomial test (α=5%). RESULTS: Accuracy with voxel sizes 0.125, 0.200, and 0.250 mm was significantly higher in the detection of ERRs and VRFs than voxel sizes 0.300 and 0.400 mm. No statistical difference was found in terms of accuracy among any of the studied voxel sizes in the identification of RPs. CONCLUSIONS: Voxel size 0.125 mm produced images with the best resolution without increasing radiation levels to the patient when compared to voxel sizes 0.200 and 0.250 mm. Voxel sizes 0.300 and 0.400 mm should be avoided in the identification of root alterations.
format Online
Article
Text
id pubmed-5146776
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-51467762016-12-19 Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition Bragatto, Fernanda Paula Iwaki Filho, Liogi Kasuya, Amanda Vessoni Barbosa Chicarelli, Mariliani Queiroz, Alfredo Franco Takeshita, Wilton Mitsunari Iwaki, Lilian Cristina Vessoni J Conserv Dent Original Research Article AIM: The aim of this study is to assess the accuracy of images acquired with cone-beam computed tomography (CBCT) in the identification of three different root alterations. MATERIALS AND METHODS: Forty human premolars were allocated to four experimental groups (n = 10): sound teeth (control), vertical root fracture (VRF), external root resorption (ERR), and root perforation (RP). After the root alterations had been produced, four teeth were randomly assembled into 10 macerated mandibles and submitted to CBCT. Images were acquired with five voxel sizes (0.125, 0.200, 0.250, 0.300, and 0.400 mm) and assessed by three experienced dental radiologists. Sensitivity, specificity, positive and negative predictive values, and the areas under the receiver operating characteristic curve (accuracy) were calculated. The accuracy of imaging in different voxel sizes was compared with Tukey exact binomial test (α=5%). RESULTS: Accuracy with voxel sizes 0.125, 0.200, and 0.250 mm was significantly higher in the detection of ERRs and VRFs than voxel sizes 0.300 and 0.400 mm. No statistical difference was found in terms of accuracy among any of the studied voxel sizes in the identification of RPs. CONCLUSIONS: Voxel size 0.125 mm produced images with the best resolution without increasing radiation levels to the patient when compared to voxel sizes 0.200 and 0.250 mm. Voxel sizes 0.300 and 0.400 mm should be avoided in the identification of root alterations. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5146776/ /pubmed/27994322 http://dx.doi.org/10.4103/0972-0707.194029 Text en Copyright: © Journal of Conservative Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Research Article
Bragatto, Fernanda Paula
Iwaki Filho, Liogi
Kasuya, Amanda Vessoni Barbosa
Chicarelli, Mariliani
Queiroz, Alfredo Franco
Takeshita, Wilton Mitsunari
Iwaki, Lilian Cristina Vessoni
Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
title Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
title_full Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
title_fullStr Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
title_full_unstemmed Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
title_short Accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
title_sort accuracy in the diagnosis of vertical root fractures, external root resorptions, and root perforations using cone-beam computed tomography with different voxel sizes of acquisition
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146776/
https://www.ncbi.nlm.nih.gov/pubmed/27994322
http://dx.doi.org/10.4103/0972-0707.194029
work_keys_str_mv AT bragattofernandapaula accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition
AT iwakifilholiogi accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition
AT kasuyaamandavessonibarbosa accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition
AT chicarellimariliani accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition
AT queirozalfredofranco accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition
AT takeshitawiltonmitsunari accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition
AT iwakililiancristinavessoni accuracyinthediagnosisofverticalrootfracturesexternalrootresorptionsandrootperforationsusingconebeamcomputedtomographywithdifferentvoxelsizesofacquisition