Cargando…

Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients

BACKGROUND: To evaluate the safety and effectiveness of the Supracor excimer laser algorithm to treat hyperopic presbyopic patients using laser in-situ keratomileusis (LASIK). METHODS: This is a retrospective case review of patients diagnosed with hyperopia (Sphere ≥ +0.0 D and presbyopia reading ad...

Descripción completa

Detalles Bibliográficos
Autores principales: Ang, Robert Edward T., Cruz, Emerson M., Pisig, Alex U., Solis, Maria Luisa Patricia C., Reyes, Rosalie Mae M., Youssefi, Gerhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146828/
https://www.ncbi.nlm.nih.gov/pubmed/27981059
http://dx.doi.org/10.1186/s40662-016-0062-6
_version_ 1782473560030183424
author Ang, Robert Edward T.
Cruz, Emerson M.
Pisig, Alex U.
Solis, Maria Luisa Patricia C.
Reyes, Rosalie Mae M.
Youssefi, Gerhard
author_facet Ang, Robert Edward T.
Cruz, Emerson M.
Pisig, Alex U.
Solis, Maria Luisa Patricia C.
Reyes, Rosalie Mae M.
Youssefi, Gerhard
author_sort Ang, Robert Edward T.
collection PubMed
description BACKGROUND: To evaluate the safety and effectiveness of the Supracor excimer laser algorithm to treat hyperopic presbyopic patients using laser in-situ keratomileusis (LASIK). METHODS: This is a retrospective case review of patients diagnosed with hyperopia (Sphere ≥ +0.0 D and presbyopia reading add ≥ 1.0 D) who underwent Supracor excimer laser treatment on at least one eye for presbyopia correction from year May 2011 to May 2013. Binocular vision was further analyzed after patients were subdivided into three groups: Group A (n = 22 eyes, 11 patients) had Supracor on both eyes; Group B (n = 18 eyes, 18 patients) had Supracor in one eye and hyperopic LASIK on fellow eye; and Group C (n = 29 eyes, 29 patients) had Supracor in one eye and no treatment on the fellow eye. RESULTS: This study evaluated 58 patients wherein 69 eyes underwent Supracor presbyopic LASIK. Preoperatively, mean manifest refraction spherical equivalent (MRSE) of all eyes that underwent Supracor was +1.37 ± 0.72 D with mean uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA) of 20/50 (0.35 logMAR), 20/50 (0.35 logMAR), and J9 (0.61 logMAR), respectively. At 6 months postoperatively, mean MRSE was −0.43 ± 0.59 D with mean UDVA, UIVA and UNVA of 20/25 (0.13 logMAR), 20/20 (0.01 logMAR), and J1 (0.05 logMAR), respectively. Loss of two lines of best-corrected distance visual acuity (BCDVA) was seen in 6% of eyes. Mean corneal steepening of 1.0 D at the 3 mm zone and 0.7 D in the 5 mm zone was observed. Mean vertical coma increased from −0.02 to +0.10 while mean 4th order spherical aberration became more negative from 0.20 to −0.14. Mean binocular UDVA, UIVA, and UNVA are 20/20, 20/20 and J1, respectively, in all treatment groups at the 6 month postoperative follow-up. No significant differences in binocular UDVA (p ≥ 0.36), UIVA (p ≥ 0.19) and UNVA (p ≥ 0.56) among groups were seen. CONCLUSIONS: Supracor excimer laser algorithm is safe and effective for the treatment of presbyopia in hyperopes. Monolateral and bilateral Supracor treatments yielded similarly good binocular vision outcomes.
format Online
Article
Text
id pubmed-5146828
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-51468282016-12-15 Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients Ang, Robert Edward T. Cruz, Emerson M. Pisig, Alex U. Solis, Maria Luisa Patricia C. Reyes, Rosalie Mae M. Youssefi, Gerhard Eye Vis (Lond) Research BACKGROUND: To evaluate the safety and effectiveness of the Supracor excimer laser algorithm to treat hyperopic presbyopic patients using laser in-situ keratomileusis (LASIK). METHODS: This is a retrospective case review of patients diagnosed with hyperopia (Sphere ≥ +0.0 D and presbyopia reading add ≥ 1.0 D) who underwent Supracor excimer laser treatment on at least one eye for presbyopia correction from year May 2011 to May 2013. Binocular vision was further analyzed after patients were subdivided into three groups: Group A (n = 22 eyes, 11 patients) had Supracor on both eyes; Group B (n = 18 eyes, 18 patients) had Supracor in one eye and hyperopic LASIK on fellow eye; and Group C (n = 29 eyes, 29 patients) had Supracor in one eye and no treatment on the fellow eye. RESULTS: This study evaluated 58 patients wherein 69 eyes underwent Supracor presbyopic LASIK. Preoperatively, mean manifest refraction spherical equivalent (MRSE) of all eyes that underwent Supracor was +1.37 ± 0.72 D with mean uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA) of 20/50 (0.35 logMAR), 20/50 (0.35 logMAR), and J9 (0.61 logMAR), respectively. At 6 months postoperatively, mean MRSE was −0.43 ± 0.59 D with mean UDVA, UIVA and UNVA of 20/25 (0.13 logMAR), 20/20 (0.01 logMAR), and J1 (0.05 logMAR), respectively. Loss of two lines of best-corrected distance visual acuity (BCDVA) was seen in 6% of eyes. Mean corneal steepening of 1.0 D at the 3 mm zone and 0.7 D in the 5 mm zone was observed. Mean vertical coma increased from −0.02 to +0.10 while mean 4th order spherical aberration became more negative from 0.20 to −0.14. Mean binocular UDVA, UIVA, and UNVA are 20/20, 20/20 and J1, respectively, in all treatment groups at the 6 month postoperative follow-up. No significant differences in binocular UDVA (p ≥ 0.36), UIVA (p ≥ 0.19) and UNVA (p ≥ 0.56) among groups were seen. CONCLUSIONS: Supracor excimer laser algorithm is safe and effective for the treatment of presbyopia in hyperopes. Monolateral and bilateral Supracor treatments yielded similarly good binocular vision outcomes. BioMed Central 2016-12-08 /pmc/articles/PMC5146828/ /pubmed/27981059 http://dx.doi.org/10.1186/s40662-016-0062-6 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ang, Robert Edward T.
Cruz, Emerson M.
Pisig, Alex U.
Solis, Maria Luisa Patricia C.
Reyes, Rosalie Mae M.
Youssefi, Gerhard
Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients
title Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients
title_full Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients
title_fullStr Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients
title_full_unstemmed Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients
title_short Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patients
title_sort safety and effectiveness of the supracor presbyopic lasik algorithm on hyperopic patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146828/
https://www.ncbi.nlm.nih.gov/pubmed/27981059
http://dx.doi.org/10.1186/s40662-016-0062-6
work_keys_str_mv AT angrobertedwardt safetyandeffectivenessofthesupracorpresbyopiclasikalgorithmonhyperopicpatients
AT cruzemersonm safetyandeffectivenessofthesupracorpresbyopiclasikalgorithmonhyperopicpatients
AT pisigalexu safetyandeffectivenessofthesupracorpresbyopiclasikalgorithmonhyperopicpatients
AT solismarialuisapatriciac safetyandeffectivenessofthesupracorpresbyopiclasikalgorithmonhyperopicpatients
AT reyesrosaliemaem safetyandeffectivenessofthesupracorpresbyopiclasikalgorithmonhyperopicpatients
AT youssefigerhard safetyandeffectivenessofthesupracorpresbyopiclasikalgorithmonhyperopicpatients