Cargando…

Comparison of marginal fit of cemented zirconia copings manufactured after digital impression with lava™ C.O.S and conventional impression technique

BACKGROUND: Evaluation of the marginal fit of cemented zirconia copings manufactured after digital impression with Lava™ Chairside Oral Scanner in comparison to that of zirconia copings manufactured after conventional impressions with polyvinyl siloxane. METHODS: A prepared typodont tooth #36, was r...

Descripción completa

Detalles Bibliográficos
Autores principales: Dauti, Rinet, Cvikl, Barbara, Franz, Alexander, Schwarze, Uwe Yacine, Lilaj, Bledar, Rybaczek, Tina, Moritz, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146899/
https://www.ncbi.nlm.nih.gov/pubmed/27931256
http://dx.doi.org/10.1186/s12903-016-0323-8
Descripción
Sumario:BACKGROUND: Evaluation of the marginal fit of cemented zirconia copings manufactured after digital impression with Lava™ Chairside Oral Scanner in comparison to that of zirconia copings manufactured after conventional impressions with polyvinyl siloxane. METHODS: A prepared typodont tooth #36, was replicated 40 times with a vinyl silicone and precise model resin. The dies were randomly divided into two groups according to the impression taking technique. Digital impressions with Lava™ C.O.S. and conventional impressions were taken according to the group. Subsequently zirconia copings were manufactured and cemented on their respective dies with zinc oxide phosphate cement. After embedding in resin, mesio-distal section of each coping was performed with a diamond saw in order to obtain two slices. One half of the specimen was used for evaluation with an optical microscope (OM) and the other half for evaluation with a scanning electron microscope (SEM). Marginal gap (MG) and absolute marginal discrepancy (AMD) were measured mesial and distal on each slice. RESULTS: No significant difference of the marginal parameters between the digital and the conventional group was found. The mean values for MG in the digital group were 96.28 μm (+/−43.21 μm) measured with the OM and 99.26 μm (+/−48.73 μm) measured with the SEM, respectively. AMD mean values were 191.54 μm (+/−85.42 μm) measured with the optical microscope and 211.6 μm (+/−96.55 μm) with the SEM. For the conventional group the mean MG values were 94.84 μm (+/−50.77 μm) measured with the OM and 83.37 μm (+/−44.38 μm) measured with the SEM, respectively. AMD mean values were 158.60 μm (+/−69.14 μm) for the OM and 152.72 μm (+/−72.36) for the SEM. CONCLUSIONS: Copings manufactured after digital impression with Lava™ C.O.S. show comparable marginal parameters with the copings manufactured after conventional impression with polyvinyl syloxane. The mean MG values of both groups fit in the clinically acceptable range. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12903-016-0323-8) contains supplementary material, which is available to authorized users.