Cargando…
Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting
The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic e...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Thoracic and Cardiovascular Surgery
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5147473/ https://www.ncbi.nlm.nih.gov/pubmed/27965925 http://dx.doi.org/10.5090/kjtcs.2016.49.6.465 |
_version_ | 1782473693403807744 |
---|---|
author | Lee, Youngok Kim, Gun-Jik Kim, Young Eun Hong, Seong Wook Lee, Jong Tae |
author_facet | Lee, Youngok Kim, Gun-Jik Kim, Young Eun Hong, Seong Wook Lee, Jong Tae |
author_sort | Lee, Youngok |
collection | PubMed |
description | The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length. |
format | Online Article Text |
id | pubmed-5147473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society for Thoracic and Cardiovascular Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-51474732016-12-13 Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting Lee, Youngok Kim, Gun-Jik Kim, Young Eun Hong, Seong Wook Lee, Jong Tae Korean J Thorac Cardiovasc Surg Case Report The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length. The Korean Society for Thoracic and Cardiovascular Surgery 2016-12 2016-12-05 /pmc/articles/PMC5147473/ /pubmed/27965925 http://dx.doi.org/10.5090/kjtcs.2016.49.6.465 Text en Copyright © 2016 by The Korean Society for Thoracic and Cardiovascular Surgery. All rights Reserved. This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Lee, Youngok Kim, Gun-Jik Kim, Young Eun Hong, Seong Wook Lee, Jong Tae Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting |
title | Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting |
title_full | Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting |
title_fullStr | Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting |
title_full_unstemmed | Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting |
title_short | Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting |
title_sort | non-anastomotic rupture of a woven dacron graft in the descending thoracic aorta treated with endovascular stent grafting |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5147473/ https://www.ncbi.nlm.nih.gov/pubmed/27965925 http://dx.doi.org/10.5090/kjtcs.2016.49.6.465 |
work_keys_str_mv | AT leeyoungok nonanastomoticruptureofawovendacrongraftinthedescendingthoracicaortatreatedwithendovascularstentgrafting AT kimgunjik nonanastomoticruptureofawovendacrongraftinthedescendingthoracicaortatreatedwithendovascularstentgrafting AT kimyoungeun nonanastomoticruptureofawovendacrongraftinthedescendingthoracicaortatreatedwithendovascularstentgrafting AT hongseongwook nonanastomoticruptureofawovendacrongraftinthedescendingthoracicaortatreatedwithendovascularstentgrafting AT leejongtae nonanastomoticruptureofawovendacrongraftinthedescendingthoracicaortatreatedwithendovascularstentgrafting |