Cargando…
Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy
We report a 38-year-old male with a nonunion followed by plate breakage after volar plating of a distal radius osteotomy. Volar locking plates have added a new approach to the treatment of distal radius malunions, due to a lower morbidity of the surgical approach and the strength of the final constr...
Autores principales: | Barrera-Ochoa, Sergi, Rodríguez-Alabau, Sergi, Sallent, Andrea, Soldado, Francisco, Mir, Xavier |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5149625/ https://www.ncbi.nlm.nih.gov/pubmed/28003828 http://dx.doi.org/10.1155/2016/6836190 |
Ejemplares similares
-
Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
por: Shinohara, Takaaki, et al.
Publicado: (2017) -
Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate
por: Tarallo, Luigi, et al.
Publicado: (2014) -
Treatment of unstable distal radius fractures with the volar locking plate
por: Minegishi, Hanae, et al.
Publicado: (2011) -
ANATOMICAL STUDY OF VOLAR FACE OF DISTAL RADIUS AND COMPARISON WITH THE SHAPE OF LOCKING VOLAR PLATES
por: LIMA, LUCIANA CASCÃO, et al.
Publicado: (2022) -
TREATMENT OF SCHAPHOID NONUNION WITH VOLAR LOCKED PLATE
por: Burgos, Felipe Hellmeister, et al.
Publicado: (2019)