Cargando…

Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion

Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right a...

Descripción completa

Detalles Bibliográficos
Autores principales: Barr, James, Acharya, Metesh Nalin, Kourliouros, Antonios, Raja, Shahzad Gull
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5149643/
https://www.ncbi.nlm.nih.gov/pubmed/28018699
http://dx.doi.org/10.1155/2016/3795640
_version_ 1782474047137775616
author Barr, James
Acharya, Metesh Nalin
Kourliouros, Antonios
Raja, Shahzad Gull
author_facet Barr, James
Acharya, Metesh Nalin
Kourliouros, Antonios
Raja, Shahzad Gull
author_sort Barr, James
collection PubMed
description Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications.
format Online
Article
Text
id pubmed-5149643
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-51496432016-12-25 Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion Barr, James Acharya, Metesh Nalin Kourliouros, Antonios Raja, Shahzad Gull Case Rep Surg Case Report Giant coronary artery aneurysms are rare clinical entities. We report the case of a 49-year-old man who presented with dyspnoea and exertional chest pain. Investigations confirmed an aneurysmal right coronary artery measuring 4 cm with a fistulous communication to the right atrium. Following right atriotomy, the fistula was oversewn and the aneurysmal right coronary artery ligated at its origin and at several points along its course. A saphenous vein graft was anastomosed to the posterior descending artery. Persistent ventricular fibrillation occurred upon chest closure, attributed to ischaemia following ligation of the aneurysmal coronary artery. Emergent resternotomy and internal defibrillation were successfully performed. The sternum was stented open to reduce right ventricular strain and closed the following day. The patient made an unremarkable recovery. We here address the technical challenges associated with surgical repair of right coronary aneurysms and the physiology and management of potential complications. Hindawi Publishing Corporation 2016 2016-11-27 /pmc/articles/PMC5149643/ /pubmed/28018699 http://dx.doi.org/10.1155/2016/3795640 Text en Copyright © 2016 James Barr et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Barr, James
Acharya, Metesh Nalin
Kourliouros, Antonios
Raja, Shahzad Gull
Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion
title Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion
title_full Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion
title_fullStr Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion
title_full_unstemmed Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion
title_short Technical Considerations of Giant Right Coronary Artery Aneurysm Exclusion
title_sort technical considerations of giant right coronary artery aneurysm exclusion
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5149643/
https://www.ncbi.nlm.nih.gov/pubmed/28018699
http://dx.doi.org/10.1155/2016/3795640
work_keys_str_mv AT barrjames technicalconsiderationsofgiantrightcoronaryarteryaneurysmexclusion
AT acharyameteshnalin technicalconsiderationsofgiantrightcoronaryarteryaneurysmexclusion
AT kourliourosantonios technicalconsiderationsofgiantrightcoronaryarteryaneurysmexclusion
AT rajashahzadgull technicalconsiderationsofgiantrightcoronaryarteryaneurysmexclusion