Cargando…

Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography

BACKGROUND: The objective of this study is to measure the diameter size of foveal avascular zone (FAZ) in both eyes of healthy young adults using optical coherence tomography (OCT) angiography. METHODS: A cross sectional study to measure the foveal avascular zone in healthy young adults. Subjects un...

Descripción completa

Detalles Bibliográficos
Autores principales: Hussain, Nazimul, Hussain, Anjli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5151126/
https://www.ncbi.nlm.nih.gov/pubmed/27994879
http://dx.doi.org/10.1186/s40942-016-0053-8
_version_ 1782474329955500032
author Hussain, Nazimul
Hussain, Anjli
author_facet Hussain, Nazimul
Hussain, Anjli
author_sort Hussain, Nazimul
collection PubMed
description BACKGROUND: The objective of this study is to measure the diameter size of foveal avascular zone (FAZ) in both eyes of healthy young adults using optical coherence tomography (OCT) angiography. METHODS: A cross sectional study to measure the foveal avascular zone in healthy young adults. Subjects underwent OCT angiography using Zeiss AngioPlex OCT angiography in both eyes. RESULTS: 30 eyes of 15 healthy young adults were evaluated. The mean horizontal FAZ diameter of superficial vascular plexus was 661.166 ± 119.99 microns and mean vertical FAZ diameter was 660.033 ± 96.169 microns (P = 0.9442). The mean horizontal FAZ diameter of deep vascular plexus was 1011.2 ± 154.526 microns and the mean vertical FAZ diameter of deep vascular plexus was 818.033 ± 102.108 microns. There was no difference between the contralateral eyes of subjects in FAZ diameter of both superficial and deep capillary plexuses. CONCLUSION: The mean diametric size of FAZ in superficial capillary plexus is 660.599 ± 0.801 microns and deep capillary plexus is 914.616 ± 136.589 microns. There was no significant difference with the contralateral eyes.
format Online
Article
Text
id pubmed-5151126
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-51511262016-12-19 Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography Hussain, Nazimul Hussain, Anjli Int J Retina Vitreous Original Article BACKGROUND: The objective of this study is to measure the diameter size of foveal avascular zone (FAZ) in both eyes of healthy young adults using optical coherence tomography (OCT) angiography. METHODS: A cross sectional study to measure the foveal avascular zone in healthy young adults. Subjects underwent OCT angiography using Zeiss AngioPlex OCT angiography in both eyes. RESULTS: 30 eyes of 15 healthy young adults were evaluated. The mean horizontal FAZ diameter of superficial vascular plexus was 661.166 ± 119.99 microns and mean vertical FAZ diameter was 660.033 ± 96.169 microns (P = 0.9442). The mean horizontal FAZ diameter of deep vascular plexus was 1011.2 ± 154.526 microns and the mean vertical FAZ diameter of deep vascular plexus was 818.033 ± 102.108 microns. There was no difference between the contralateral eyes of subjects in FAZ diameter of both superficial and deep capillary plexuses. CONCLUSION: The mean diametric size of FAZ in superficial capillary plexus is 660.599 ± 0.801 microns and deep capillary plexus is 914.616 ± 136.589 microns. There was no significant difference with the contralateral eyes. BioMed Central 2016-12-12 /pmc/articles/PMC5151126/ /pubmed/27994879 http://dx.doi.org/10.1186/s40942-016-0053-8 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Article
Hussain, Nazimul
Hussain, Anjli
Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography
title Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography
title_full Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography
title_fullStr Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography
title_full_unstemmed Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography
title_short Diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography
title_sort diametric measurement of foveal avascular zone in healthy young adults using optical coherence tomography angiography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5151126/
https://www.ncbi.nlm.nih.gov/pubmed/27994879
http://dx.doi.org/10.1186/s40942-016-0053-8
work_keys_str_mv AT hussainnazimul diametricmeasurementoffovealavascularzoneinhealthyyoungadultsusingopticalcoherencetomographyangiography
AT hussainanjli diametricmeasurementoffovealavascularzoneinhealthyyoungadultsusingopticalcoherencetomographyangiography