Efficacy, safety, tolerability and pharmacokinetics of a novel human immune globulin subcutaneous, 20%: a Phase 2/3 study in Europe in patients with primary immunodeficiencies
A highly concentrated (20%) immunoglobulin (Ig)G preparation for subcutaneous administration (IGSC 20%), would offer a new option for antibody replacement therapy in patients with primary immunodeficiency diseases (PIDD). The efficacy, safety, tolerability and pharmacokinetics of IGSC 20% were evalu...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5167020/ https://www.ncbi.nlm.nih.gov/pubmed/27613250 http://dx.doi.org/10.1111/cei.12866 |
Sumario: | A highly concentrated (20%) immunoglobulin (Ig)G preparation for subcutaneous administration (IGSC 20%), would offer a new option for antibody replacement therapy in patients with primary immunodeficiency diseases (PIDD). The efficacy, safety, tolerability and pharmacokinetics of IGSC 20% were evaluated in a prospective trial in Europe in 49 patients with PIDD aged 2–67 years. Over a median of 358 days, patients received 2349 IGSC 20% infusions at monthly doses equivalent to those administered for previous intravenous or subcutaneous IgG treatment. The rate of validated acute bacterial infections (VASBIs) was significantly lower than 1 per year (0·022/patient‐year, P < 0·0001); the rate of all infections was 4·38/patient‐year. Median trough IgG concentrations were ≥ 8 g/l. There was no serious adverse event (AE) deemed related to IGSC 20% treatment; related non‐serious AEs occurred at a rate of 0·101 event/infusion. The incidence of local related AEs was 0·069 event/infusion (0·036 event/infusion, when excluding a 13‐year‐old patient who reported 79 of 162 total related local AEs). The incidence of related systemic AEs was 0·032 event/infusion. Most related AEs were mild, none were severe. For 64·6% of patients and in 94·8% of IGSC 20% infusions, no local related AE occurred. The median infusion duration was 0·95 (range = 0·3‐4·1) h using mainly one to two administration sites [median = 2 sites (range = 1–5)]. Almost all infusions (99·8%) were administered without interruption/stopping or rate reduction. These results demonstrate that IGSC 20% provides an effective and well‐tolerated therapy for patients previously on intravenous or subcutaneous treatment, without the need for dose adjustment. |
---|